Plan Review Details - Permit 01030667
| Plan Review Stops For Permit 01030667 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-04-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-25 |
Time |
15:32 |
Rev Time |
0.01 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-03-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-03-29 |
Time |
16:49 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-29 00:00:00 | PERMIT # 01030667 | | | 415 SUNSET RD | | | MARION CONSTRUCTION | | | 659-5292 | | | | | | 1)- SBC 104.2.2: ADDITIONAL INFORMATION, | | | MISSING COLUMN AND BEAM SCHEDULE, VERTIC | | | AL DOWN RODS, SIZE & FREQUENCY, THE BEAM | | | SIZE STEEL AND HOOP PLACEMENT OVER THE | | | GARAGE DOOR AS WELL AS THE OPEN PORCH. | | | | | | 2)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | SBC 1707.4 EXTERIOR WINDOWS & DOORS; | | | GLAZED OPENINGS SHALL BE TESTED FOR A | | | PERIOD OF TIME OF 10 SECONDS AT A LOAD | | | OF 1.5 TIMES THE DESIGN PRESSURE. THIS | | | ALSO INCLUDES GARAGE DOORS.SBCCI OR | | | DADE COUNTY PRODUCT APPROVAL REPORTS | | | ARE ACCEPTTED. | | | | | | 3)- SBC 1707.4.1: GLAZED OPENINGS RE- | | | QUIRE TESTING FOR LARGE MISSLE IMPACT | | | TESTING, IF THE OPENINGS HAVEN'T | | | RECEIVED TESTING STORM SHUTTERS WILL BE | | | REQUIRED, CITY POLICY ALSO REQUIRES A | | | SCHEDULE FOR INSTALATION. | | | | | | 4)- SBC 104.2.2 MISSING INFORMATION ON | | | THE TRUSS LAYOUT. | | | | | | 5)- COUNTY IMPACT FEES NEED TO BE PAID | | | AT THE COUNTY BUILDING DEPARTMENT. | | | | | | 6)- STATE RADON FEES $12.00 TO BE PAID | | | TO THE CITY. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-04-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-19 |
Time |
19:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-19 |
Time |
19:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-23 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-23 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2001-03-23 00:00:00 | *************** UNSAT **************** | | | | | | 1) PLEASE NOTE EITHER MISSING EGRESS | | | LIGHTING AND/OR CLARIFY EGRESS LIGHTING | | | PER 210-70 OF THE NEC. GRADE LEVEL | | | ACCESS FROM GARAGE. | | | | | | 2) PLEASE CLARIFY EQUIPMENT GROUNDING | | | METHOD BETWEEN FIRST MEANS OF | | | DISCONNECTAND PANEL AT DETACHED GARAGE. | | | CONDUCTORS ARE TO BE SIZED BY 250-122. | | | | | | 3) NOTE: PLEASE SHOW GROUNDING | | | ELECTRODEGOING TO BUILDING STEEL AND | | | COLD WATER | | | PER 250-50 AT DEATCHED GARAGE. | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE AREANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2001-03-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-20 |
Time |
18:52 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-03-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-20 |
Time |
18:50 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-03-20 |
Time |
18:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-03-19 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-03-19 |
Time |
11:19 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|