Plan Review Details - Permit 01030534
Plan Review Stops For Permit 01030534
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2001-08-28 Cont ID  
Sent By jgomez Date 2001-08-28 Time 14:12 Rev Time 0.25
Received By jgomez Date 2001-08-28 Time 14:12 Sent To  
Notes
2001-08-28 00:00:00APPROVED WITH PROVISO:
  
 1-APPLY FOR SEPARATE PERMITS FOR
 ELECTRICAL, MECHANICAL AND PLUMBING
 WORK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2001-08-20 Cont ID  
Sent By jgomez Date 2001-08-20 Time 17:36 Rev Time 0.25
Received By jgomez Date 2001-08-20 Time 17:36 Sent To  
Notes
2001-08-20 00:00:00CHECKLIST:
  
 1-ORIGINAL ENERGY CALCULATIONS WERE NOT
 REVISED AS REQUESTED ON PREVIOUS
 CHECKLISTS.
 NOTE: BRING ENERGY CALCULATIONS TO
 THOMAS ABBOTT (PERSON WHO PREPARED THE
 ORIGINAL ENERGY CALCULATIONS).
 I TALKED TO THOMAS ABBOT ABOUT THIS
 ENERGY CALCULATIONS. HE KNOWS WHAT TO
 DO FOR RENOVATION PROJECTS.
 NOTE: ENGINEER OF RECORD TO SIGN, SEAL
 & DATE THE REVISED ENERGY CALCULATIONS
 & PROVIDE HIS INFORMATION AS REQUIRED
 BY CHAPTER 471 OF FLORIDA STATUTES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2001-08-06 Cont ID  
Sent By jgomez Date 2001-07-28 Time 12:26 Rev Time 1.50
Received By jgomez Date 2001-07-28 Time 12:26 Sent To  
Notes
2001-07-28 00:00:001-REVISE ORIGINAL ENERGY CALCULATIONS
 TO SHOW EXISTING STRUCTURE (NOT NEW),
 ACTUAL NUMBER OF UNITS, FLOOR TYPE.
 NOTE: ENERGY CALCS FOR MULTIFAMILY UNITS
 TO BE SIGNED & SEALED BY THE ENGINEER.
 2-APPLY FOR SEPARATE PERMITS FOR
 ELECTRICAL, MECHANICAL AND PLUMBING
 WORK.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2001-07-13 Cont ID  
Sent By jgomez Date 2001-07-13 Time 13:02 Rev Time 1.00
Received By jgomez Date 2001-07-13 Time 13:02 Sent To  
Notes
2001-07-13 00:00:00THIRD CHECKLIST:
 1-ENERGY CALCULATIONS ARE WRONG:
 A)THIS IS NOT A NEW BUILDING.
 B)NUMBER OF UNITS IS WRONG.
 C)NO INFORMATION ON FLOOR TYPES.
 D)WHAT ABOUT UNITS ON THE FIRST FLOOR?
 E)OWNER/AGENT TO SIGN AND DATE AT THE
 BOTTOM OF ENERGY CALCULATIONS FORM.
 2-CLEARLY SPECIFY SIZE & TYPE OF EGRESS
 WINDOWS. WHAT'S A 24EH WINDOW?
 -PRODUCT APPROVAL SUBMITTED IS FOR
 SINGLE HUNG WINDOWS. A 24SH WINDOW
 DOESN'T COMPLY WITH THE MINIMUM EGRESS
 REQUIREMENTS OF SEC. 1005.4 SBC 1997.
 3-SPECIFY SIZE OF ENTRY DOORS TO COMPLY
 WITH TABLE 1004 SBC 1997.
 4-PRODUCT APPROVAL FOR DOORS REQUIRES A
 2X STRUCTURAL BUCK. ENGINEER TO
 PROVIDE 2X STRUCTURAL BUCK DETAIL.
 -PROVIDE BUCK DETAIL FOR WINDOWS TOO.
 5-NEED TO APPLY FOR SEPARATE PERMITS FOR
 MECHANICAL, PLUMBING & ELECTRICAL WORK
 6-NEED TO APPLY FOR SEPARATE PERMITS FOR
 FENCE AND FOR PARKING WORK.
 7-SPECIFY HOW IS THE ONE HOUR TENANT
 SEPARATION ACHIEVED BETWEEN THE FIRST
 AND SECOND FLOOR. SEC 704.3 SBC 1997.
 8-CONTRACTOR NEEDS TO UPDATE INSURANCE.
 9-SEE COMMENTS BY THE FIRE CAPTAIN.
 10-ENGINEER TO SEE COMMENTS ON PLANS.
  
  
 NOTE:
 ENGINEER NEEDS TO REVISE ORIGINAL DWGS
 AND PROVIDE THE REQUESTED INFORMATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-05-07 Cont ID  
Sent By jgomez Date 2001-05-07 Time 12:00 Rev Time 1.50
Received By jgomez Date 2001-05-07 Time 12:00 Sent To  
Notes
2001-05-07 00:00:00SECOND CHECKLIST:
  
 1-PROVIDE ENERGY CALCULATIONS (NOT DONE
 FROM PREVIOUS CHECKLIST.
 2-CLEARLY SPECIFY SIZE AND TYPE OF
 EGRESS WINDOWS TO VERIFY THAT THEY
 COMPLY WITH SECTION 1005.4 SBC 1997.
 -CLARIFY WHAT IS (2)24 EH SPECIFIED ON
 PLANS.
 -IF THESE ARE TO BE SINGLE HUNG WINDOWS
 THEN SIZE 24 DOESN'T COMPLY WITH THE
 EGRESS REQUIREMENTS SEC 1005.4 SBC/97.
 3-PROVIDE TWO COPIES OF CURRENT PRODUCT
 APPROVALS FOR WINDOWS AND DOORS TO BE
 REPLACED.
 4-NEED TO APPLY FOR SEPARATE PERMITS FOR
 MECHANICAL, PLUMBING AND ELECTRICAL
 WORK.
 5-NEED TO APPLY FOR SEPARATE PERMIT FOR
 CONCRETE BLOCK FENCE AND FOR PARKING
 WORK.
 6-SPECIFY HOW IS THE ONE HOUR TENANT
 SEPARATION ACHIEVED BETWEEN FIRST AND
 SECOND FLOOR. SEC 704.3 SBC 1997.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-03-30 Cont ID  
Sent By jgomez Date 2001-03-30 Time 15:43 Rev Time 1.00
Received By jgomez Date 2001-03-30 Time 15:43 Sent To  
Notes
2001-03-30 00:00:00CHECKLIST:
 1-DRAWINGS NEED TO BE SIGNED, SEALED AND
 DATED BY THE ENGINEER AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTES.
 2-PROVIDE ENERGY CALCULATIONS.
 3-CLEARLY SPECIFY SIZE AND TYPE OF
 EGRESS WINDOWS TO VERIFY THAT THEY
 COMPLY WITH SEC 1005.4 SBC 1997.
 4-PROVIDE CURRENT SBCCI OR DADE COUNTY
 PRODUCT APPROVAL FOR ALL WINDOWS AND
 EXTERIOR DOORS TO BE REPLACED.
 5-NEED TO APPLY FOR SEPARATE PERMITS FOR
 MECHANICAL, PLUMBING AND ELECTRICAL
 WORK. PROVIDE COMPLETE INFORMATION SO
 PLAN REVIEWERS FOR THOSE DISCIPLINES
 CAN PERFORM THEIR REVIEWS.
 6-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS AND SEC 2405.2 SBC 1997.
 7-THE 6' PRIVACY WALL TO BE DONE UNDER
 A SEPARATE PERMIT. PROVIDE SURVEY
 SHOWING EXACT LOCATION AND COMPLETE
 CONSTRUCTION DETAILS.
 -WILL NEED LETTER OF RELEASE FROM THE
 UTILITIES DEPARTMENT.
 8-PARKING WORK NEED TO BE DONE UNDER A
 SEPARATE PERMIT. PROVIDE COMPLETE
 INFORMATION WHEN APPLYING FOR SUCH
 PERMIT.
 9-CLARIFY IF HAND RAILS ARE NEW, THEN
 PROVIDE COMPLETE INSTALLATION DETAILS.
 -SPECIFY CONNECTIONS.
 10-CONSTRUCTION VALUE DECLARED BY THE
 CONTRACTOR IS EXTREMELY LOW. PROVIDE A
 DETAILED TAKE OFF OF THE SCOPE OF WORK
  
  
  
  
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2001-08-03 Cont ID  
Sent By jgomez Date 2001-08-03 Time 12:21 Rev Time 0.00
Received By jgomez Date 2001-08-03 Time 12:21 Sent To  
Notes
2001-08-03 00:00:00GENERAL CONTRACTOR SAID SUB-CONTRACTOR
 WILL PULL OUT SEPARATE PERMIT.

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2002-01-14 Cont ID  
Sent By dpalmer Date 2001-05-07 Time 15:11 Rev Time 0.00
Received By dpalmer Date 2001-05-07 Time 15:09 Sent To  
Notes
2001-05-07 00:00:00***************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT PLAN NOTES
 CALLFOR ELECTRICAL WORK WITH NO DETAIL
 FOR
 THAT WORK. PLEASE SUBMIT MORE DETAIL.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2001-08-02 Cont ID  
Sent By mcarsill Date 2001-08-02 Time 15:37 Rev Time 0.00
Received By mcarsill Date 2001-08-02 Time 15:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2001-07-05 Cont ID  
Sent By mcarsill Date 2001-07-05 Time 14:53 Rev Time 0.00
Received By mcarsill Date 2001-07-05 Time 14:53 Sent To  
Notes
2001-07-05 00:00:001) STILL NEED MORE INFORMATION ON
 EGRESS WINDOWS PLANNED FOR USE.
 2) STILL NEED INFORMATION ON INTERIOR
 FINISH.
 3) PLEASE PROVIDE WIDTHS FOR NEW DOORS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-05-10 Cont ID  
Sent By mcarsill Date 2001-05-10 Time 09:20 Rev Time 0.00
Received By mcarsill Date 2001-05-10 Time 09:20 Sent To  
Notes
2001-05-10 00:00:001) PLEASE EXPLAIN DOORS ON STAIRS. THEY
 APPEAR TO OPEN OUTWARD ONTO THE
 BALCONY LEAVING VERY LITTLE ROOM.
 2) PLEASE EXPLAIN NOTES FOR THE EGRESS
 WINDOWS.
 3) NO INTERIOR FINISH INFORMATION
 PROVIDED FOR WALLS AND CEILINGS OF
 APARTMENTS. PLEASE SPECIFY CLASS A, B,
 OR C.
 4) WHAT SIZES ARE THE DOORS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-04-06 Cont ID  
Sent By mcarsill Date 2001-04-06 Time 08:02 Rev Time 0.00
Received By mcarsill Date 2001-04-06 Time 08:02 Sent To  
Notes
2001-04-06 00:00:001) APARTMENT DOORS ARE TO BE AT LEAST
 20 MINUTE FIRE RATED AND BE EQUIPPED
 WITH SELF-CLOSING DEVICES.
 2) INTERIOR FINISH ON WALLS AND CEILINGS
 TO BE CLASS A OR B. PLEASE NOTE THIS
 ON PLANS.
 3) NO DETAILS PROVIDED FOR EMERGENCY
 EGRESS WINDOWS.
 4) TENANT SEPARATION BETWEEN APARTMENTS
 TO COMPLY WITH BUILDING CODE
 REQUIREMENTS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 4 Status N Date 2001-08-20 Cont ID  
Sent By pkrauss Date 2001-08-20 Time 10:21 Rev Time 0.40
Received By pkrauss Date 2001-08-20 Time 10:16 Sent To  
Notes
2001-08-20 00:00:00*******************DENIED***************
  
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE SUBMIT PLANS WITH MECHAN
 ICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2001-07-25 Cont ID  
Sent By pkrauss Date 2001-07-25 Time 14:04 Rev Time 0.25
Received By pkrauss Date 2001-07-25 Time 14:04 Sent To  
Notes
2001-07-25 00:00:00*******************DENIED***************
  
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.PLEASE SUBMIT PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-07-06 Cont ID  
Sent By pkrauss Date 2001-07-06 Time 14:59 Rev Time 0.40
Received By pkrauss Date 2001-07-06 Time 14:59 Sent To  
Notes
2001-07-06 00:00:00********************DENIED**************
  
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.
  
 PROVIDE EQUIPMENT INFORMATION (MAKE,
 MODEL, SEER, HEAT KW, ETC.)
  
 SHOW LOCATIONS OF EQUIPMENT BEING
 INSTALLED AS WELL AS DUCT & GRILL SIZES.
  
 INDICATE SIZE AND TERMINATION OF
 CONDENSATE.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-05-11 Cont ID  
Sent By pkrauss Date 2001-05-11 Time 14:37 Rev Time 0.25
Received By pkrauss Date 2001-05-11 Time 14:34 Sent To  
Notes
2001-05-11 00:00:00*******************DENIED***************
  
 INSUFFICIENT INFORMATION FOR MECHANICAL
 REVIEW.
  
 PLEASE PROVIDE MECHANICAL PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE
 CONTACTPATTY KRAUSS AT 659-8096 EXT.
 8388.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-05-07 Cont ID  
Sent By kstevens Date 2001-05-07 Time 17:27 Rev Time 0.33
Received By kstevens Date 2001-05-07 Time 17:27 Sent To  
Notes
2001-05-07 00:00:00REVIEW NOTES.PASSED
  
 WATER HEATER PANS REQUIRED FOR WATER
 HEATERS ON SECOND FLOOR, WITH 1" DRAIN
 LINES TERMINATING OUTSIDE 6" ABOVE THE
 GROUND.
  
  
 REVIEW BY KEN STEVENS (561) 659-8096
 EXT. 8377

Review Stop Z ZONING
Rev No 1 Status P Date 2001-08-06 Cont ID  
Sent By sgraham Date 2001-08-06 Time 08:14 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***