Plan Review Details - Permit 01030495
Plan Review Stops For Permit 01030495
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-07-11 Cont ID  
Sent By jgomez Date 2001-07-11 Time 13:52 Rev Time 1.00
Received By tjonseck Date 2001-07-11 Time 13:52 Sent To  
Notes
2001-07-11 00:00:00APPROVED WITH PROVISO:
  
 1-EGRESS WINDOWS TO COMPLY WITH SECTION
 1005.4 SBC 1997:
 -20" MINIMUM CLEAR WIDTH OPENING.
 -24" MINIMUM CLEAR HEIGHT OPENING.
 -5 SQ. FT. MINIMUM TOTAL CLEAR OPENING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-03-31 Cont ID  
Sent By jgomez Date 2001-03-31 Time 11:58 Rev Time 0.50
Received By jgomez Date 2001-03-31 Time 11:58 Sent To  
Notes
2001-03-31 00:00:00CHECKLIST:
  
 1-PROVIDE SKETCH OR SOME SORT OF KEY
 PLAN SHOWING SIZE AND LOCATION OF
 EGRESS WINDOWS IN ORDER TO VERIFY
 COMPLIANCE WITH EGRESS REQUIREMENTS
 OF SECTION 1005.4 SBC 1997.
  
 2-PROVIDE COMPLETE INFORMATION FOR
 STORM PANELS:
 -PROVIDE KEY PLAN AND A COMPLETE
 INSTALLATION SCHEDULE AS PER CITY
 SAMPLE ATTACHED.
 -CLEARLY INDICATE ON STORM PANEL DWGS
 THE SPECIFIC MOUNTING CONDITIONS AND
 ANCHOR TYPE AND SPACING TO BE USED
 ACCORDING TO THE MEAN ROOF HEIGHT,
 DESIGN PRESSURES, PANEL SPAN, EDGE
 DISTANCE, CONNECTION TYPE & STRUCTURE
 TO BE ATTACHED TO (CONCRETE BLOCK OR
 WOOD).
  
 3-VALUE DECLARED BY THE CONTRACTOR FOR
 THE SCOPE OF WORK TO BE PERFORMED IS
 VERY LOW. PROVIDE A DETAILED TAKE OFF
 SHOWING REALISTIC NUMBERS.
  
  
  
  
 -IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.