Plan Review Details - Permit 01030464
| Plan Review Stops For Permit 01030464 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-04-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-28 |
Time |
08:33 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-03-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-03-28 |
Time |
17:41 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-28 00:00:00 | 5 MANGONIA CIRCLE | | | O/B: RUSSEL, PERCIVAL/ | | | BONNICK, CURTIS | | | PERMIT # 01030464 | | | | | | 1)- SBC 1804.2 SOIL TEST REPORT, | | | BEARING VALUE | | | | | | 2)- SBC 1707.4.1 STORM SHUTTERS: | | | WEST PALM POLICY SEE ATTACHMENT KEY AND | | | SAMPLE INSTALLATION SCHEDULE. | | | | | | 3)- SBC 1606.2..6.2.: COMPONENTS & | | | CLADDING. MISSING PRODUCT APPROVAL | | | REPORTS FOR: | | | A): SLIDING GLASS DOORS | | | B): FRONT DOOR & SIDE LITE | | | | | | 4)- SBC 102.2.2: ADDITIONAL INFORMATION: | | | THERE IS NO ATTACHMENT DETAIL FOR THE | | | (2) 2X12 WOOD BEAMS LOCATED OVER THE | | | FRONT ENTRY, THE DETAIL DOESN'T CLARIFY | | | HOW TO TIE BACK INTO THE ROOF TRUSSES. | | | | | | 5)- TRUSS DRAWING; CAN'T LOCATE THE | | | TTRUSSES 15,16 & 17. | | | | | | 6)- PLANS ARE TO BE STAMPED BY THE | | | COUNTY FOR IMPACT FEES. | | | | | | 7)- ADDITIONAL FEES DUE TO CITY: | | | 1000:$418.94 | | | 123016.81 | | | 121011.37 | | | 122011.37 | | | _______ | | | | | | TOTAL $458.49 | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-05-17 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-05-17 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-25 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-25 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2001-04-25 00:00:00 | ****************** UNSAT ************* | | | | | | 1)NOTE: PLEASE NOTE THAT NOT ALL NOTES | | | WERE ADDRESSED. | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | THE CODE ARTYS: WERE WRITTEN ON PLANS?? | | | THIS DOES NOT GIVE US THE AIC RATING | | | FORNEW EQUIPMENT. | | | | | | 3)NOTE: PLEASE NOTE THAT ALL THE OTHER | | | CHANGES THAT WERE MADE, WERE DONE IN | | | PENCIL? THIS IS NOT PERMITTED UNDER | | | 104.2 AND 104.2.7. ALSO ALL PLANS THAT | | | ARE SIGNED AND SEALED BY AN | | | ARCH/ENGINEER ARE TO BE DONE BY THAT | | | PERSON PER F.S. AND F.A.C 471.025 AND | | | 481.221. | | | | | | PLEASE HAVE PLANS RE-DONE UNDER COUNTY | | | AND CITYWIDE ADMINISTRATIVE CODE. | | | 104.2& .7. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-03-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-26 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-26 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2001-03-26 00:00:00 | **************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE THAT LOAD | | | CALCULATIONS AND LOADS ON PANEL | | | SCHEDULE ARE NOT COMPLETE. PLEASE DO | | | SO. 215-5. | | | | | | 2)NOTE: PLEASE NOTE LOADS FOR LIGHTING, | | | WELL PUMP, SPRINKLER PUMP?? | | | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 4) NOTE: PLEASE SHOW GROUNDING | | | ELECTRODE GOING TO BUILDING STEEL AND | | | COLD WATER. PER 250-50 | | | PLEASE NOTE THAT WE ARE | | | UNDER THE "99" NEC. THERE IS A NOTE REF | | | TO | | | ART 250-83C? THIS IS NOT IN THE "99"NEC. | | | | | | 5) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG. | | | | | | PLEASE NOTE THAT IF THERE IS GOING TO BE | | | CATV AND OR TELEPHONE IN THE HOUSE THEN | | | LOCATIONS NEED TO BE SHOWN ON PLANS. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-03-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-24 |
Time |
06:53 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-03-24 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-03-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-20 |
Time |
18:13 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-03-20 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2001-03-20 00:00:00 | PROVISO: | | | SANITARY RISER DIAGRAM DOES NOT | | | MEET CODE. SUBMIT SANITARY RISER | | | DIAGRAM FOR INSPECTION. MUST REFLECT | | | FLOOR PLAN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-05-17 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-05-17 |
Time |
14:52 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|