Plan Review Details - Permit 01021196
| Plan Review Stops For Permit 01021196 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2002-02-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-02-12 |
Time |
14:28 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-04-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-06 |
Time |
11:44 |
Rev Time |
0.70 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-04-06 00:00:00 | WILL REQUIRE INFORMATION ON THE | | | GAURD PAVILION |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2002-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-02-12 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-02-11 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2002-02-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-02-12 |
Time |
14:28 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
2001-04-05 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2001-04-05 00:00:00 | ONLY #2 OR LARGER CAN BE USED WHEN USING | | | ALNOT ALLOWED FOR GROUNDING! |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2001-07-17 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-07-17 |
Time |
15:39 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2001-07-17 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2001-07-17 00:00:00 | PASSED: | | | 1. SEE PERMIT # 01060486 | | | | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2002-02-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-02-07 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-02-07 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2002-02-07 00:00:00 | 1) A KNOX-BOX KEY SWITCH WILL BE | | | REQUIRED INSTEAD OF THE KNOX-BOX | | | AS SHOWN ON THE PLANS. | | | 2) PLEASE INDICATE WHAT HAPPENS WHEN | | | LOSS OF POWER OCCURS TO THE ENTRY GATE | | | SYSTEM. PROVISIONS ARE TO BE MADE FOR | | | FIRE RESCUE ACCESS INTO THE GATES WHEN | | | THE GATES LOSE POWER. | | | 3) PLEASE PROVIDE WEIGHT LIMIT ON | | | ROAD THAT EXISTS OVER BULKHEAD. | | | 4) ANY PROPERTY THAT THE FIRE DEPARTMENT | | | IS REQUIRED TO PROTECT SHALL HAVE | | | SUITABLE ACCESS GATES,ROADS,LANES, ETC. | | | MINIMUM WIDTH OF TWENTY FEET IS | | | REQUIRED. | | | 5) THE MEDIAN LOCATED NEAR WINDSOR WAY | | | MAY EFFECT TURNING AND SHOULD BE | | | REDUCED TO ALLOW FOR GREATER TURNING | | | RADIUS FOR FIRE APPARATUS. | | | A LETTER IS TO BE PROVIDED REGARDING | | | THESE ITEMS FROM THE ARCHITECT. | | | | | | APPROVED PROVISO: | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2002-02-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-02-12 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2002-02-11 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2002-02-12 00:00:00 | ZONING: PER MIKE SANCHEZ02/112/02 JW | | 2002-02-11 00:00:00 | PUT IN ZONING BY JIM WITMER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2001-10-25 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-10-25 |
Time |
09:25 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-25 00:00:00 | DECORATIONS ON WALL NEED TO BE 12" NOT | | | 24" |
|
|
|
Account Summary | Usage Policy | Privacy Policy