Plan Review Details - Permit 01021189
Plan Review Stops For Permit 01021189
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2002-01-10 Cont ID  
Sent By jwitmer Date 2002-01-10 Time 16:06 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-10 00:00:00MASTER: 01021178

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-09-07 Cont ID  
Sent By jleahy Date 2001-09-07 Time 15:26 Rev Time 4.00
Received By jleahy Date 2001-09-07 Time 15:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-07-11 Cont ID  
Sent By jleahy Date 2001-07-11 Time 14:46 Rev Time 2.00
Received By jleahy Date 2001-07-11 Time 14:44 Sent To  
Notes
2001-07-11 00:00:00SAME AS BEFORE1200 AMP MAIN AND
 LESS THAN 1200 AMPS OF WIRE
 SEE 240-3C
 SEE 240-3C
 SEE 240-3C
 SEE 240-3C

Review Stop E ELECTRICAL
Rev No 1 Status R Date 2002-01-10 Cont ID  
Sent By jwitmer Date 2002-01-10 Time 16:07 Rev Time 0.00
Received By jwitmer Date 2001-05-24 Time 12:24 Sent To  
Notes
2001-05-24 00:00:00PAGE E-202 HAS A 1200 AMP MAIN WITH ONLY
 1125 AMPS OF WIRE240-3C, 110-16C2

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2001-07-17 Cont ID  
Sent By mamini Date 2001-07-17 Time 15:28 Rev Time 1.00
Received By mamini Date 2001-07-17 Time 15:28 Sent To  
Notes
2001-07-17 00:00:00PASSED:
 1. SEE PERMIT # 01060486
  
 IF ANY QUESTION PLEASE CONTACT 659-8096
 EXT. 8492 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2002-01-10 Cont ID  
Sent By jwitmer Date 2002-01-10 Time 16:07 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-10 00:00:00MASTER: 01021178

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-08-28 Cont ID  
Sent By mcarsill Date 2001-08-28 Time 15:01 Rev Time 0.00
Received By mcarsill Date 2001-08-28 Time 15:01 Sent To  
Notes
2001-08-28 00:00:00THE TEMPORARY FIRE PROTECTION BY USING
 DRY HYDRANTS AND A PORTABLE PUMP WILL
 NOT BE ACCEPTED BY THIS OFFICE.
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-08-02 Cont ID  
Sent By mcarsill Date 2001-08-02 Time 12:14 Rev Time 0.00
Received By mcarsill Date 2001-08-02 Time 12:14 Sent To  
Notes
2001-08-02 00:00:001) THE WATER SUPPLY ISSUE FOR FIRE
 HYDRANTS DURING CONSTRUCTION HAS NOT
 BEEN RESOLVED. A WATER MAIN EXTENSION
 HAS TO BE DONE AND THE DEVELOPER HAS
 ALTERNATE IDEAS TO ADDRESS THIS ISSUE.
 A LETTER IS TO BE PROVIDED TO THIS
 OFFICE.
 2) NOTE ON PAGE A-1.2. INDICATES
 BUILDING WILL NOT BE SPRINKLERED. THIS
 IS NOT CORRECT.
 3) STORAGE NOT PERMITTED UNDERNEATH
 EXIT STAIRS. STORAGE AREA MUST BE
 RATED SAME AS THE SATIR.
 4) HOW IS DRYER VENT EXHAUST RISER
 CLEANED OF COMBUSTIBLE LINT.
 5) HOW ARE THE OUTER EXIT STAIRS BEING
 ILLUMINATED SHOULD THE POWER BE LOST.
 6) BUILDING ADDRESS REQUIRED PER CITY
 CODE 3343-00.
 7) FIRE ALARM RISER SHOWS E.O.L.'S. ONLY
 CLASS A OR FULLY ADDRESSABLE FIRE ALARM
 SYSTEMS ARE PERMITTED.
 8) PROVIDE MORE DETAILS FOR EGRESS
 WINDOWS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2001-08-17 Cont ID  
Sent By pkrauss Date 2001-08-17 Time 15:17 Rev Time 0.35
Received By pkrauss Date 2001-08-17 Time 15:17 Sent To  
Notes
2001-08-17 00:00:00PREVIOUS COMMENTS UNDER 01021175
 ADDRESSED SATISFACTORY BY REV 4
 SEE COMMENTS UNDER ABOVE PERMIT NUMBER

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-07-12 Cont ID  
Sent By pkrauss Date 2001-07-12 Time 12:02 Rev Time 1.00
Received By pkrauss Date 2001-07-12 Time 12:02 Sent To  
Notes
2001-07-12 00:00:00*******************PROVISO**************
  
 TYPE II
  
 NOTHING ON PLANS HAVE CHANGED.
  
 PLEASE TAKE NOTE TO THE FOLLOWING ISSUES
  
  
  
 1.AS STATED IN REVIE DATED 6/5/01,
 PLAN M-206 DETAIL OF A/C CLOSET,
 PROVIDE OVERFLOW PAN FOR UPPER
 FLOORS ONLY.... OVERFLOW PAN SHALL
 GO ON EVERY FLOOR TO PREVENT DAMAGE
 TO CARPET, WALLS AND INTERIOR OF
 APARTMENT.
  
 2.AS DISCUSSED IN MEETING WITH CARLOS
 AT CITY HALL, AS PER AMENDED 1997
 SPC 804.3, #5 CONDENSATE DRAINS
 SHALL VENT TO ATMOSPHERE, IT SHALL
 NOT VENT INTO THE WALL AS SHOWN ON
 THE DETAIL.SHOULD TERMINATION BE
 IN THE ATTIC, IT SHALL BE A MINIMUM
 OF 6" ABOVE THE INSULATION.
  
 PLESAE REMOVE/CORRECT NOTES THAT REFER
 TO DETAILS ON PLANS THAT ARE NOT IN THE
 PLAN SET OR ARE ON A DIFFERENT PLAN ALL
 TOGETHER (EXAMPLE:SHAFT ENCLOSURE IS
 SAID TO BE ON ARCHITECTURAL PLAN SHEET
 A-13 #25).
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 PATTY KRAUSS AT 659-8096 EXT. 8388.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-06-05 Cont ID  
Sent By pkrauss Date 2001-06-05 Time 13:43 Rev Time 2.30
Received By pkrauss Date 2001-06-05 Time 13:43 Sent To  
Notes
2001-06-05 00:00:00REVIEW DONE UNDER PERMIT 01201175.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-04-06 Cont ID  
Sent By pkrauss Date 2001-04-06 Time 14:59 Rev Time 1.30
Received By pkrauss Date 2001-04-06 Time 14:59 Sent To  
Notes
2001-04-06 00:00:00*******************DENIED***************
  
 TYPE II
 REVIEW UNDER 01021178.

Review Stop P PLUMBING
Rev No 2 Status P Date 2002-01-10 Cont ID  
Sent By jwitmer Date 2002-01-10 Time 16:08 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-10 00:00:00MASTER: 01021178

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-07-14 Cont ID  
Sent By jleech Date 2001-07-14 Time 13:54 Rev Time 1.00
Received By jleech Date 2001-07-14 Time 13:54 Sent To  
Notes
2001-07-14 00:00:00REVIEW NOTES UNDER PERMIT # 01021175

Review Stop Z ZONING
Rev No 1 Status P Date 2002-01-10 Cont ID  
Sent By jwitmer Date 2002-01-10 Time 16:08 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2002-01-10 00:00:00MASTER: 01021178