| Plan Review Stops For Permit 01021178 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2002-09-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-09-20 |
Time |
13:39 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2002-09-20 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2002-09-20 00:00:00 | REV# 4 9/9/02OKJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2002-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-02-06 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-02-06 00:00:00 | GARAGE DOOR: PRESSURES LOW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2001-11-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-27 |
Time |
11:57 |
Rev Time |
3.50 |
| Received By |
jwitmer |
Date |
2001-11-27 |
Time |
11:57 |
Sent To |
|
|
| Notes |
| 2001-11-27 00:00:00 | SAN MARINO PROJECT | | | TYPE II BUILDING | | | MASTER# 01021178 | | | | | | 1)- THE REVISIONS SUBMITTED NOV.1/01 TO | | | THE BUILDING DEPARTMENT AS REVISION DATE | | | 9/28/01 ARE IDENTICAL TO THE PLANS ON RE | | | CORD. THE DELTA OR TRIANGLE IDENTIFICA- | | | TION ISN'T GIVING ENOUGH INFORMATION TO | | | DETERMINE WHAT THE ACTUAL REVISION IS | | | FOR? IT MAY HELP TO HAVE A SUMMARY FOR | | | EACH PAGE WHAT THE REVISION IS ABOUT. | | | 2) THE MECHANICAL SHEETS INDICATE A VENT | | | ILATION SHAFT, THE SBC TABLE 705.1.2 | | | INDICATES THAT A 1 HR RATING WILL BE | | | REQUIRED FOR STUCTURES LESS THAN 4 STOR- | | | IES. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2001-09-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-09-27 |
Time |
12:02 |
Rev Time |
5.00 |
| Received By |
jwitmer |
Date |
2001-09-27 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2001-09-27 00:00:00 | MASTER BUILD MODEL II | | | BUILDING # 4,13 & 15 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2001-07-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-24 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2001-09-27 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2001-07-24 00:00:00 | BUILDING TYPE II | | | PLAN CHECK : 01021178 | | | | | | 1)- ALL BUILDING COMMENTS HAVE BEEN | | | IMPLEMENTED WITH EXECTION TO GLAZED OPEN | | | INGS, NO INFORMATION ON WINDOWS, | | | DOORS, & GARAGE DOORS. SEE CITY POLICY | | | FOR LARGE MISSLE IMPACT RESISTANT | | | GLAZING & STORM SHUTTERS. | | | 2)- THERE IS ALSO NO PRODUCT INFORMATION | | | FOR THE ROOFING SYSTEM. | | | | | | JIM WITMER | | | (561) 659-8096 X 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-06-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-06-12 |
Time |
08:48 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-12 00:00:00 | TYPE II BUILDING | | | BUILDINGS # 4,13 &15 | | | PLAN REVIEW # 01021178 | | | ARCH: MOURIZ SALAZAR | | | PHONE;: (305) 273-9911 | | | FAX: (305) | | | | | | BUILDING 4 TYPE II | | | | | | SAME COMMENTS AS RREVIEW 01021175 & | | | GENERAL COMMENTS UNDER CLUBHOUSE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-04-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-04 |
Time |
15:10 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-04-04 00:00:00 | TYPE II BUILDING | | | BUILDING # 4,13 & 15 | | | PROJECT: 01021178 | | | ARCH. MOURIZ SALAZAR | | | PHONE (305) 273-9911 | | | FAX)305) | | | BUILDING 4TYPE II | | | | | | 1)- SBC 1007.3.1: STAIR CALCULATION | | | REQUIRES BETWEEN >24" &<25". | | | | | | 2)- GENERAL STRUCTURAL NOTES S-4 (11) | | | DESIGN LOADS, | | | A)- DESIGN IS TO COMPLY WITH THE 1997 | | | STANDARD BUILDING CODE. | | | B)- WIND LOAD CRITERIA, BASIC LOAD | | | VELOCITY 110 MPH, ASCE 7-95. | | | | | | 3)- FAIR HOUSING ACT CHAPTER 6. | | | A)- LOCATION OF GRAB BARS FOR TUB IS | | | 32" MIN. & 38" MAXIMUM. | | | B)- WATER CLOSET BACKING BEHIND THE | | | WATER CLOSET WHEN THER IS NO WING | | | WALL.SEE PAGES A-5.1,5.2,5.3, 5.6 | | | AND 5.10. | | | C)_ A 5.6 MASTER BATH LAV DOES NOT MEET | | | THE PARALLEL APPROACH AT THE LAV, | | | 30" X 48" ARE REQUIRED. | | | D)- SHEET A-6: MAIL BOXES: FAIR HOUSING | | | CHAPTER 2 REFERS TO FL ACCC CODE | | | REACH & RANGES, SIDE APPROACH | | | SECTION (4.2.6) MAX. HEIGTH 54" | | | MIN. HEITH 0"-9". | | | E)_ S-1.1, (4) C-1 APARTMENTS DEPICTS | | | 1/2" VERTICAL DROP + THRESHOLD, SEE | | | FL ACC. CODE 4.13.8 THRESSHOLDS AT | | | DOORWAYS, 2/1. | | | | | | 4)- SHEET A-9 DETAIL #28: SOFFIT DETAIL | | | DOESN'T GIVE THE ANCHORAGE TO THE STRUC- | | | TURAL SLAB ABOVE. | | | | | | 5)_ SHEET A 4.1 2ND FL UNIT C-1 DETAILS | | | 39/43, MISSING1 LAYER OF 1/2"DRYWALL. | | | | | | 6)SH A4-5 NOTE 20, HI BIBBED LATH, | | | SBC 2504.2.2 SEC ASTM C 1063.7.10.23 | | | 3/8" RIB LATH ATTACHED TO HORIZONTAL | | | WOOD SUPPORTS REQUIRES NAILS OR STAPLES | | | TO PROVIDE 1 3/4" PENETRATION INTO | | | HORIZONTAL WOOD SUPPORTS, 3/4" INTO | | | VERTICAL SUPPORTS. | | | | | | 7)- SHEET A 3.1 NOTE #12, CANVAS AWNINGS | | | ON TUBULAR STEEL FRAMES REQUIRES A SEP- | | | ERATE PERMIT, (PER BUILDING). | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-01-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2002-01-23 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2002-01-23 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2001-11-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-11-07 |
Time |
22:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-11-07 |
Time |
22:37 |
Sent To |
|
|
| Notes |
| 2001-11-07 00:00:00 | *************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT CHANGES ON | | | PLANS NEED TO BE IDENTIFIED BY CLOUDS | | | OR TRIANGLES. | | | | | | PLEASE SUBMIT FOR REVIEW. IF THERE ARE | | | ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-09-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2001-09-07 |
Time |
15:07 |
Rev Time |
4.00 |
| Received By |
jleahy |
Date |
2001-09-07 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2001-09-07 00:00:00 | NO ROMEX TO BE USED, CHECK CLEARANCE ON | | | DISCONNECTS, CHECK WATERHEATERS FOR | | | DISCONNECTS WHEN NOT INSIGHT OF PANEL |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-05-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2001-05-24 |
Time |
12:23 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2001-05-24 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2001-05-24 00:00:00 | PAGE E-202 HAS A 1200 AMP MAIN WITH ONLY | | | 1125 AMPS OF WIRE240-3C, 110-14C2 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2001-07-17 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-07-17 |
Time |
16:04 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2001-07-17 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2001-07-17 00:00:00 | PASSED: | | | 1. SEE PERMIT # 01060486 | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2002-02-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-02-12 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-02-12 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2002-02-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2002-02-07 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2002-02-07 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2002-02-07 00:00:00 | 1) MECHANICAL NOTES REGARDING | | | VENTILATION SHAFT IS NOT CORRECT. | | | REVISED PLANS ARE TO BE MORE DETAIL | | | SO THE REVISIONS CAN BE PROPERLY | | | RECOGNIZED. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2001-11-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-11-21 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-21 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2001-11-21 00:00:00 | 1) PLEASE EXPLAIN VENTILATION SHAFT. | | | SHAFTS ARE REQUIRED TO BE FIRE RATED. | | | THE SHAFT ON PAGES M-203,204 AND 205 | | | INDICATE VENTILATION SHAFTS. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-09-25 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-09-25 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-09-25 |
Time |
08:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-08-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-28 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-28 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2001-08-28 00:00:00 | THE TEMPORARY FIRE PROTECTION BY USING | | | DRY HYDRANTS AND A PORTABLE PUMP WILL | | | NOT BE ACCEPTED BY THIS OFFICE. | | | | | | MIKE CARSILLO, CAPTAIN | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2002-02-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-12 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2002-01-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-01-30 |
Time |
10:56 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2002-01-30 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2002-01-30 00:00:00 | *******************DENIED*************** | | | | | | | | | PREVIOUS COMMENTS NEVER ADDRESSED. | | | | | | PLAN SHEET M-204 NOTES:#4 1, | | | "VENTILATION SHAFT (NOT A FIRE RATED | | | CHASE)". | | | | | | DUCTS PENETRATING MORE THAN 1 FLOOR | | | SHALL BE PROTECTED BY A SHAFT ENCLOSURE | | | AS PER 1997 SMC 610.4 & NFPA 90A 3-3.4. | | | 1 HOUR RATING FOR BUILDINGS LESS THAN 4 | | | STORIES AND 2 HOUR RATING FOR 4 STORIES | | | AND MORE IN HEIGHT. | | | | | | THE ABOVE ISSUE WAS DISCUSSED IN A | | | MEETING ON JANUARY18, 2002.PLEASE | | | SEE ATTACHED LETTER. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2001-11-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-11-19 |
Time |
15:03 |
Rev Time |
0.50 |
| Received By |
pkrauss |
Date |
2001-11-19 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2001-11-19 00:00:00 | ******************DENIED**************** | | | | | | | | | REVISED PLAN SHEETS M-203,204 & 205 | | | UNDER NOTES:4. (1) VENTILATION SHAFT | | | NOT A FIRE RATED CHASE.AS PER 1997 | | | SMC 610.4, DUCTS EXTENDING THROUGH MORE | | | THAN ONE FLOOR SHALL BE PROTECTED BY A | | | SHAFT ENCLOSURE HAVE A FIRE RESISTANCE | | | OF NOT LESS THAN 1 HOUR FOR BUIDLINGS | | | LESS THAN FOUR STORIES IN HEIGHT (2 HR - | | | FOR BUIDLINGS 4 STORIES AND MORE). | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 | | | EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2001-08-17 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-08-17 |
Time |
15:16 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-17 00:00:00 | ******************PROVISO*************** | | | | | | | | | DRYER EXHAUST SHALL HAVE A BACK DRAFT | | | DAMPER AS PER 509.3. | | | | | | PLEASE REMOVE / CORRECT NOTES THAT REFER | | | TO DETAIL ON PLANS THAT ARE NOT IN THE | | | PLAN SEST OF HAVE BEEN ADDRESSED ON A | | | DIFFERENT PLAN (EXAMPLE: PLAN SHEET | | | M-204 NOTES, SHAFT ENCLOSER DETAIL SEE | | | ARCHITECTURAL PLAN SHEET M-206). | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-07-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-07-12 |
Time |
10:48 |
Rev Time |
1.00 |
| Received By |
pkrauss |
Date |
2001-07-12 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2001-07-12 00:00:00 | *******************PROVISO************** | | | | | | TYPE IV | | | | | | NOTHING ON PLANS HAVE CHANGED. | | | | | | PLEASE TAKE NOTE TO THE FOLLOWING ISSUES | | | | | | | | | 1.AS STATED IN REVIEW DATED 6/5/01, | | | PLAN M-106 DETAIL OF A/C CLOSET, | | | PROVIDE OVERFLOW PAN FOR UPPER | | | FLOORS ONLY....OVERFLOW PAN SHALL | | | GO ON EVERY FLOOR TO PREVENT DAMAGE | | | TO CARPET, WALLS AND INTERIOR OF | | | APARTMENT. | | | | | | 2.AS DISCUSSED IN MEETING WITH CARLOS | | | AT CITY HALL, AS PER AMENDED 1997 | | | SPC 804.3, #5. CONDENSATE DRAINS | | | SHALL VENT TO ATMOSPHERE, IT SHALL | | | NOT VENT INTO THE WALL AS SHOWN ON | | | THE DETAIL.SHOULD TERMINATION BE | | | IN THE ATTIC, IT SHALL BE A MINIMUM | | | OF 6" ABOVE THE INSULATION. | | | | | | PLEASE REMOVE/CORRECT NOTES THAT REFER | | | TO DETAILS ON PLANS THAT ARE NOT IN THE | | | PLAN SET OR ARE ON A DIFFERENT PLAN ALL | | | TOGETHER (EXAMPLE:SHAFT ENCLOSURE IS | | | SAID TO BE ON ARCHITECTURAL PLAN SHEET | | | A-13 #25). | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS 659-8096 EXT. 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-06-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-06-05 |
Time |
13:13 |
Rev Time |
2.30 |
| Received By |
pkrauss |
Date |
2001-06-05 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2001-06-05 00:00:00 | REVIEW DONE UNDER PERMIT 01021175. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-04-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-04-06 |
Time |
14:42 |
Rev Time |
1.30 |
| Received By |
pkrauss |
Date |
2001-04-06 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2001-04-06 00:00:00 | ******************DENIED**************** | | | | | | APARTMENT BUILDING #4, 13 & 15TYPE II |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2001-12-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-12-15 |
Time |
12:03 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-12-16 00:00:00 | COMPLETE SET OF REVISIONS,PES | | 2001-12-15 00:00:00 | REVISION, OKPES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2001-11-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-21 |
Time |
10:45 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-11-21 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2001-11-21 00:00:00 | REVISION DENIED | | | REFERENCE: SPC-94 - FHA AMEND 98 DESIGN | | | MANUAL | | | | | | 1) REVISION PAGES DO NOT MATCH PAGE NUM- | | | ER IN MASTER SET REVIEWED FOR PERMIT. | | | | | | 2) ALL REVISIONS SHALL BE DATED AND IN- | | | DICATED WITH EITHER A CLOUD, DART. OR | | | TRIANGLE FOR REVIEW | | | | | | 3) PLEASE RESUBMIT REVISION WITH MATCH- | | | PAGE NUMBERS AND SHOW WHAT IS BEING | | | REVISED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-11-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-16 |
Time |
11:33 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-11-16 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2001-11-16 00:00:00 | DENIED | | | | | | 1) PLEASE DATE REVISIONS SO THEY CAN BE | | | SEPARATED FROM PAST AND/OR FUTURE REVIS- | | | IONS. | | | | | | 2) REVISIONS SHALL BE INDICATED WITH | | | DARTS, TRIANGLES, OR CLOUDS TO INDICATE | | | WHERE REVISIONS ARE LOCATED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-09-07 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-09-07 |
Time |
15:25 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-09-07 00:00:00 | PLUMBING PLAN REVIEW, PROVISO. | | | WATER HAMMER ARRESTORS INSTALLED FOR | | | SIZE AND LOCATION, PER MFG INSTRUCTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-07-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-07-16 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2001-07-16 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2001-07-16 00:00:00 | SEE PLAN REVIEW NOTES PERMIT #01021194 | | | AND 01021175. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-10-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-10-03 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-10-03 00:00:00 | ZON: MICHEAL SANCHEUZ 10/3/01 |
|
|