Plan Review Details - Permit 01021122
Plan Review Stops For Permit 01021122
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-04-24 Cont ID  
Sent By dpalmer Date 2001-04-24 Time 20:30 Rev Time 0.00
Received By dpalmer Date 2001-04-24 Time 20:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-03-11 Cont ID  
Sent By dpalmer Date 2001-03-11 Time 15:00 Rev Time 0.00
Received By dpalmer Date 2001-03-11 Time 15:00 Sent To  
Notes
2001-03-11 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW EQUIPMENT BEING INSTALLED.
 MAINS/PANELS/BREAKERS MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
  
 2) NOTE: PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) PER 210-11-C-3.
 MUST BE 20A AND #12AWG.
  
 3) NOTE: PLEASE SHOW GROUNDING ELECTRODE
 GOING TO BUILDING STEEL AND COLD WATER
 PER 250-50.
  
 4)NOTE: PLEASE NOTE THAT YOU SHOW AN
 EQUIPMENT GROUNDING CONDUCTOR FROM METER
 TO PANEL. ONLY AFTER FIRST MEANS OF
 DISCONNECT.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.,
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-08-22 Cont ID  
Sent By pkrauss Date 2001-08-22 Time 10:40 Rev Time 0.35
Received By pkrauss Date 2001-08-22 Time 10:40 Sent To  
Notes
2001-08-22 00:00:00MECH PERMIT 01021148

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-03-10 Cont ID  
Sent By jleech Date 2001-03-10 Time 07:38 Rev Time 0.25
Received By jleech Date 2001-03-10 Time 07:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2001-11-29 Cont ID  
Sent By kstevens Date 2001-11-29 Time 11:18 Rev Time 0.33
Received By kstevens Date 2001-11-29 Time 11:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-11-14 Cont ID  
Sent By kstevens Date 2001-11-14 Time 17:37 Rev Time 0.50
Received By kstevens Date 2001-11-14 Time 17:37 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-04-25 Cont ID  
Sent By kstevens Date 2001-04-25 Time 18:50 Rev Time 0.25
Received By kstevens Date 2001-04-25 Time 18:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-03-10 Cont ID  
Sent By jleech Date 2001-03-10 Time 07:39 Rev Time 0.25
Received By jleech Date 2001-03-10 Time 07:38 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-10-10 Cont ID  
Sent By rmcdouga Date 2001-10-10 Time 09:04 Rev Time 1.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-10-10 00:00:00REVISION TO DELETE PRIVACY WALL BECAUSE
 THEIR IS AN EXISTING PRIVACY WALL ON
 ADJOINING LOT #9. O.K. 10-10-01

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2001-04-07 Cont ID  
Sent By lsmith Date 2001-04-09 Time 09:38 Rev Time 3.00
Received By lsmith Date   Time   Sent To  
Notes
2001-04-09 00:00:00PER LOU HATTEN

Review Stop Z ZONING
Rev No 1 Status P Date 2001-03-08 Cont ID  
Sent By sgraham Date 2001-03-08 Time 07:34 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy