Plan Review Details - Permit 01020979
Plan Review Stops For Permit 01020979
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date 2001-05-11 Cont ID  
Sent By lsmith Date 2001-05-11 Time 12:23 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2001-06-13 Cont ID  
Sent By dpalmer Date 2001-06-13 Time 18:52 Rev Time 0.00
Received By dpalmer Date 2001-06-13 Time 18:52 Sent To  
Notes
2001-06-13 00:00:00NO ELECTRICAL DETAIL SUBMITTED FOR
 REVIEW.

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2001-05-11 Cont ID  
Sent By lsmith Date 2001-05-11 Time 12:23 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2001-05-02 Cont ID  
Sent By mamini Date 2001-05-02 Time 09:11 Rev Time 5.00
Received By mamini Date 2001-05-02 Time 09:04 Sent To  
Notes
2001-05-02 00:00:00PASSED:
 1. RESPONSES TO PREVIOUS REVIEW COMMENTS
 DATED 03-06-01 SATISFACTORY.PLANS
 REVISED PER REVIEW COMMENTS.
 IF ANY QUESTIONS PLEASE CONTACT 561-659-
 8096 EXT. 8492 MOHAMMAD R. AMINI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 0001-03-06 Cont ID  
Sent By mamini Date 0001-03-06 Time 08:31 Rev Time 5.00
Received By mamini Date 2001-03-06 Time 08:21 Sent To  
Notes
2001-02-27 00:00:00FAILED:
 1. PLAN NOTES AND MANHOLE COVERS REFER
 TO OTHER MUNICIPALITIES, PLEASE CORRECT
 TO CITY OF WEST PALM BEACH, SEE SHEET
 15, 19, 21 AND 25.
 2. PLEASE ADD NOTES STATING THAT THE
 CONTRACTOR TO OBTAIN ALL THE REQUIRED
 PERMITTING FOR LANE CLOSURE DURING THE
 ROADWAY CONSTRUCTION.
 3. NEW SHOULDER, SWALE AREA ALONG THE
 45TH STREET SHOULD BE SODDED.
 4. USE DOUBLE LINE 4" WIDE TO DIMENSION
 THE PARKING STALL PER CITY OF WPB
 REQUIREMENT.
 5. ALL DRIVEWAY REPAIR / REPLACEMENT
 SHOULD BE PER CITY OF WPB'S STANDARD AND
 DETAILS.
 6. TRUCK WASHOUT AREA SHOULD BE PROVIDED
 DURING THE CONSTRUCTION. THIS WOULD BE
 ADDED TO THE EROSION / POLLUTION CONTROL
 PLAN. YOU MAY CONTACT THE CITY OF WPB
 FOR DETAILS.
 7. IF THE GARBAGE IS TO BE PICKED UP BY
 THE CITY OF WPB, THEN DUMPSTER WHICH
 MEETS THE CITY'S REQUIREMENT SHOULD BE
 DETAILED.YOU MAY CONTACT THE CITY OF
 WPB FOR DETAILS.
 8. WE RECOMMEND THAT YOU ADD A RECYCLING
 CENTER TO YOUR DUMPSTER ENCLOSURE.
 9. PLEASE PROVIDE PERVIOUS AND
 IMPERVIOUS AREA COMPUTATIONS IN A 8 1/2
 X 11 SHEET SIGNED AND SEALED BY THE
 DESIGN ENGENEER.IT WILL INCLUDE
 PROJECT NAME, PROPERTY CONTROL NUMBER
 AND ADDRESS.THIS DATA WILL BE USED TO
 COMPUTE THE STORM WATER CHARGES TO THE
 PROPERTY.THIS CAN BE DONE WITH PERMIT
 APPLICATION.
 10. SHOW THE LOCATION AND CONNECTION
 FOR WATER METER AND BACKFLOW PREVENTERS.
 11. SHOW THE LOCATION AND CONNECTION
 FOR IRRIGATION METER AND BACKFLOW
 PREVENTERS.
 12. ALL BACKFLOW PREVENTERS SHOULD BE
 COMPLETELY HIDDEN FROM VIEW WITH SHRUBS
 PRIOR TO ACTIVATION.
 13. ALL METERS SHOULD BE ACCSSIBLE.
 14. SHOW THE LOCATION OF CLEAN OUT
 POINTS.
 15. SHOW THE LOCATION OF SAMPLE PIONTS
 ON WATER LINES.
 16. NO TREES, PLANTS, SIGN POSTS, SHALL
 BE PLACED WITHIN 5' OF ANY HYDRANTS,
 CLEAN OUT, WATER METERS, SANITARY AND
 STORM WATER LINES.
 17. SHOW THE LOCATIONS OF WATER, SEWER,
 STORM WATER CONFLITS AND REFER TO THE
 APPROPRIATE DETAILS / PLAN PROFILES.
 18. PLEASE VERIFY THAT THE SITE PLAN FOR
 LIFT STATION AS SHOWN ON SHEET 22
 APPLIES.
 19. PLEASE CONTINUE THE SERVICES TO THE
 END OF PROPERTY ON 45TH STREET.
 20. PLEASE PROVIDE EASEMENT FROM THE
 LOCATION OF CONNECTIONS TO 45TH STREET.
 21. CONTACT PUBLIC UTILITIES DEPARTMENT
 FOR LATEST DETAILS / CHART, FOR THRUST
 BLOCKS.
 22. A R.O.W PERMIT MUST BE OBTAINED AT
 PUBLIC UTILITIES ENGINEERING SERVICES
 FOR ALL WORK WITHIN THE R.O.W.
 23. CONTRACTOR SHALL MAINTAIN A FREE
 FLOW OF TRAFFIC DURING CONSTRUCTION.
 24. CONTACT ORVILLE POLK 561- 659-8005
 EXT. 2008 PRIOR TO INSTALLING BACKFLOWS
 AND DCDA.
 25. FOR STANDARD DETAILS PLEASE CONTACT
 JANICE TARBILL 561-659-8088 EXT. 2303
 26. PLEASE SUBMIT SHOP DRAWING ON ALL
 MATERIALS USED IN R.O.W TO PUBLIC
 UTILITIES ENGINEERING SERVICES DIVISION:
 1000 45TH STREET WEST PALM BEACH FL
 33415.
 27. 1-800432-4770 CALL SUNSHINE LOCATION
 SERVICES. 48 HOURS BEFORE DIGGING.
 SHOULD BE ON ALL SHEETS WHERE UTILITIES
 WILL BE INSTALLED IN THE R.O.W.
 28. FOR CONNECTIONS AND ALL THE WORKS IN
 CITY'S R.O.W, PLEASE CONTACT, PUBLIC
 UTILITIES ENGINEERING SERVICES
 1000 45TH STREET WEST PALM BEACH, FL
 33415561-659-8040 EXT. 2306
 IF ANY QUESTION PLEASE CONTACT
 561- 659- 8096 EXT. 8492

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-06-08 Cont ID  
Sent By mcarsill Date 2001-06-08 Time 14:57 Rev Time 0.00
Received By mcarsill Date 2001-06-08 Time 14:57 Sent To  
Notes
2001-06-08 00:00:001) WET FIRE HYDRANTS ARE TO BE PROVIDED
 PRIOR TO, DURING AND AFTER CONSTRUCTION.
 2) CITY CODE SECTION 11-4 REQUIRES THAT
 NO OBSTRUCTIONS OCCUR WITHIN 18 FEET
 OF ANY FIRE HYDRANT.
  
 APPROVED PROVISO:
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2001-05-01 Cont ID  
Sent By mcarsill Date 2001-05-01 Time 13:50 Rev Time 0.00
Received By mcarsill Date 2001-05-01 Time 13:49 Sent To  
Notes
2001-05-01 00:00:001) ANOTHER FIRE HYDRANT WILL BE REQUIRED
 ON 45TH STREET NEAR THE EMPLOYEE
 ENTRANCE DRIVEWAY.
 2) ALL FIRE MAINS THAT ARE PLANNED FOR
 INSTALLATION TO BE FIRE PROTECTION
 LISTED AND COMPLY WITH NFPA 24, THE
 STANDARD FOR FIRE SERVICE MAINS AND
 THEIR APPURTENCES.
 3) PLEASE PROVIDE MORE DETAILS ON FIRE
 PUMP HOUSE SHOWN ON SHEET 14 OF 26.
 PLEASE INDICATE IF THE FIRE PUMP WILL
 BE ELECTRIC OR DIESEL. WHAT SIZE FIRE
 PUMP IS PLANNED?
  
 CAPTAIN MIKE CARSILLO
 659-8096 EXT. 8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-02-28 Cont ID  
Sent By mcarsill Date 2001-02-28 Time 11:31 Rev Time 0.00
Received By mcarsill Date 2001-02-28 Time 11:31 Sent To  
Notes
2001-02-28 00:00:001) THE PLANS MAKE REFERENCE TO OTHER
 CITIES REGARDING THE FIRE HYDRANTS,
 MANHOLES AND OTHER APPURTENANCES. PLEASE
 CLARIFY UTILITY ARRANGEMENTS TO THIS
 OFFICE PRIOR TO ANY FURTHER PLAN REVIEWS
 BEING CONDUCTED.
 2) IF THE BUILDING FALLS UNDER THE
 JURISIDICTION OF THE CITY OF WEST PALM
 BEACH, PLEASE EXPLAIN THE GUARD BOOTH
 CANOPY ELEVATION. IF FIRE TRUCKS AND
 PARAMEDICAL EQUIPMENT ARE EXPECTED TO
 PASS UNDERNEATH IT, IT MUST PROVIDE AN
 ELEVATION OF AT LEAST 13' - 6" ABOVE
 GRADE.
 3) A FIRE LANE WILL BE REQUIRED FOR THE
 BUILDING. THE REQUIRED FIRE LANE(S)
 SHALL BE AT LEAST 20 FEET IN CLEAR WIDTH
 AND BE PROPERLY IDENTIFIED WITH
 APPROPRIATE SIGNAGE AND PAVEMENT
 MARKINGS.
 4) IF THE BUILDING FALLS UNDER THE
 AUSPICES OF WEST PALM BEACH, THEN THE
 BUILDING ADDRESS IS TO COMPLY WITH
 CITY CODE REQUIREMENTS.
 5) GATES WHEN INSTALLED ARE TO BE
 ACCESSIBLE TO FIRE AND PARAMEDICAL
 EQUIPMENT.
 6) FIRE HYDRANTS AND FIRE MAINS TO
 COMPLY WITH NFPA 24, THE STANDARD FOR
 UNDERGROUND FIRE MAINS AND THEIR
 APPURTENANCES.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2001-06-13 Cont ID  
Sent By pkrauss Date 2001-06-13 Time 12:15 Rev Time 0.30
Received By pkrauss Date 2001-06-13 Time 12:00 Sent To  
Notes
2001-06-13 00:00:00 
 NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE SUBMIT PLANS WITH
 MECHANICAL PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT.8388.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-05-11 Cont ID  
Sent By lsmith Date 2001-05-11 Time 12:23 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-06-10 Cont ID  
Sent By pschmitz Date 2001-06-10 Time 14:08 Rev Time 1.50
Received By pschmitz Date   Time   Sent To  
Notes
2001-06-10 00:00:00PLUMBING PLAN REVIEW "PASS"
 (1) SITE WORK ONLY,5' OUTSIDE OF BLDG.
 NO BUILDING PLANS WITH THIS PERMIT.
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS561-659-8096X8233

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-05-06 Cont ID  
Sent By pschmitz Date 2001-05-06 Time 15:49 Rev Time 1.50
Received By pschmitz Date   Time   Sent To  
Notes
2001-05-06 00:00:00PLUMBING PLAN REVIEW, PROVISO
 BACK FLOW PROTECTION ON EACH WATER
 SERVICE,EX. LIFT STA,DOMESTIC,FIRE,
 IRRIGATION WATER.
 END OF COMMENTSPAUL SCHMITZ

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-03-05 Cont ID  
Sent By jleech Date 2001-03-05 Time 16:10 Rev Time 2.50
Received By pschmitz Date 2001-03-05 Time 16:10 Sent To  
Notes
2001-03-05 00:00:00DENIED;
  
 SEE ENGINEERING NOTES, #1 10 11 17 23.

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***