| Plan Review Stops For Permit 01020942 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-04-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-12 |
Time |
15:36 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-04-12 00:00:00 | PROVISO: IMPACT FEES TO BE PAID JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-03-06 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-03-06 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-06 00:00:00 | THIS BUILDING APPEARS TO EXCEED THE | | | 16000 FEET IN AREA ALLOTTED BY TABLE | | | 500 FOR TYPE IV CONSTRUCTION EVEN WITH | | | AREA INCREASES APPLIED.PLEASE PROVIDE | | | A SURVEYSO THAT COMPLIANCE MAY BE | | | DETERMINED. | | | | | | SBC F102.2.5 REQUIRES CERTAIN BUILDINGS | | | LOCATED IN THE FIRE DISTRICT TO BE | | | ONE HOUR PROTECTED.PLEASE REVISE AS | | | NECESSARY | | | | | | ALSO SHOW THE FIRE RATED MIXED OCCUPANCY | | | SEPARTION REQUIRED BY SBC 704.1. | | | | | | THE MEZZANINE SHOWN ON SHEET A4.1 DOES | | | NOT MEET THE CRITERIA FOR A MEZZANINE | | | CONTAINED IN SBC 503.2.3 AND IS A STORY. | | | | | | TWO INDEPENDENT MEANS OF EGRESS ARE | | | REQUIRED FROM THE SECOND FLOOR.SEE | | | SBC 1004.2.1 AND SBC 1027.1.SEE ALSO | | | "EXIT DISCHARGE" REQUIEMENTS OF SBC | | | 1010.1. | | | | | | THE EXIT STAIRS ARE REQUIED TO BE | | | ENCLOSED BY SBC 1006.1 AND THE STORAGE | | | AREA UNDER THE STAIRS REQUIRES ONE HOUR | | | RATING IN ACCORDANCE WITH SBC 1006.1. | | | | | | SHOW THE TYPE AND QUANTITY OF MATERIALS | | | TO BE STORED SO THAT COMPLIANCE WITH SBC | | | 312.2 MAY BE DETERMINED. | | | | | | INDICATE WHERE OR PROVIDE AS NECESARY, | | | THE FIRE RATED SEPARATION REQUIRED BY | | | SBC 411.5.3. | | | | | | THE NEW GLAZING MUST COMPLY WITH THE | | | CITY'S HURRICANE MISSILE IMPACT | | | RESISTANCE POLICY. | | | | | | IMPACT FEES MUST BE PAID TO THE COUNTY | | | FOR THE CITY, ON THE PROPOSED NEW AREA. | | | CALL 233-5025 FOR MORE INFORMATION. | | | | | | SHOW HOW THE VENTILATION FOR THE NEW | | | AREA WILL BE PROVIDED.SEE SMC 403 | | | (MECHANICAL CODE). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2001-04-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-25 |
Time |
19:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-25 |
Time |
19:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-04-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-16 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-16 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2001-04-16 00:00:00 | ******************* UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT ORIGINAL | | | COMMENTS WERE NOT ADDRESSED. PLEASE | | | SUBMIT ELECTRICAL DETAIL. | | | | | | IF THERE ARE NAY QUESTIONS, PLEASE CALL. | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-03-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-07 |
Time |
21:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-07 |
Time |
21:10 |
Sent To |
|
|
| Notes |
| 2001-03-07 00:00:00 | **************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE THAT NO ELECTRICAL | | | DETAILS WERE SUBMITTED FOR COMPLETE | | | REVIEW. PLEASE NOTE THAT NEW WALLS/MEZZ | | | ETC WILL REQ` ELEC. | | | | | | PLEASE SUBMIT INFORMATION FOR REVIEW, | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-04-26 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-04-26 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-04-26 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-04-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-04-11 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-04-11 |
Time |
09:07 |
Sent To |
|
|
| Notes |
| 2001-04-11 00:00:00 | 1) PLAN REVIEW COMMENTS NOT ADEQUATELY | | | ADDRESSED. PLEASE PROVIDE THE | | | NECESSARY INFORMATION. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-03-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-03-09 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-03-01 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2001-03-09 00:00:00 | 1) WRONG LIFE SAFETY CODE REFERENCED | | | ON PLANS. SHOULD READ 1985 EDITION | | | INSTEAD OF 1997 EDITION. | | | 2) STORAGE ROOMS OR AREAS TO BE | | | SEPARATED FROM OTHER PARTS OF THE | | | BUILDING BY AT LEAST ONE HOUR AND ALL | | | OPENINGS SHALL BE PROTECTED BY | | | SELF-CLOSING FIRE DOORS. RE: NFPA 101, | | | THE LIFE SAFETY CODE, 1985 EDITION, | | | SECTION 27-3.2, PROTECTION FROM HAZARDS. | | | 3) PLEASE EXPLAIN RATIONALE FOR A | | | SINGLE MEANS OF EGRESS FROM THE SECOND | | | FLOOR. | | | 4) NO EMERGENCY LIGHTING SHOWN FOR THE | | | SECOND FLOOR. | | | 5) NO INTERIOR FINISH INFORMATION SHOWN | | | ON THE PLANS. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2001-04-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-04-20 |
Time |
11:33 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2001-04-20 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2001-04-20 00:00:00 | NO MECHANICAL PLANS FOR REVIEW. | | | | | | PLEASE SUBMIT PLANS WITH MECHANICAL | | | PERMIT APPLICATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2001-03-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-03-09 |
Time |
12:13 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-03-09 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2001-03-09 00:00:00 | ******************DENIED**************** | | | | | | NO MECHANICAL PLANS FOR REVIEW. | | | MECHANICAL NOTE ON DWG. A3.1 #5 STATES | | | MECHANICAL CONTRACTOR TO RELOCATE | | | EXISTING HVAC SUPPLY AND RETURN | | | DIFFUSERS & DUCTWORK TO ACCOMMODATE NEW | | | CONSTRUCTION.REBALANCE SYSTEM UPON | | | COMPLETION OF WORK. | | | | | | SUBMIT MECHANICAL PLANS WITH MECHANICAL | | | PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2001-05-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2001-05-02 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2001-05-02 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-05-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2001-05-02 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|