| Plan Review Stops For Permit 01020941 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-04-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-23 |
Time |
07:12 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-03-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-03-14 |
Time |
11:40 |
Rev Time |
4.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-14 00:00:00 | PERMIT #01020941 | | | 420 OKEECHOBEE BLVD | | | SUNCOAST AUTO BUILDERS | | | (727) 561-0764 | | | | | | 1)- SBC 104.2.2: ADDITIONAL INFORMATION, | | | SURVEY SIGNED,SEALED AND DATED LESS THAN | | | ONE YEAR OLD.F102.2.6SITE PLAN TO SHOW A | | | ASSUMED PROPERTY LINE BETWEEN BUILDINGS. | | | 2)- SBC 1606.4.1 COUNTY AMENDMENTS: | | | FOR GLAZED OPENINGS, WINDOWS & DOORS | | | TESTING REPORTS FOR LARGE MISSLE IMPACT | | | RESISTANCE ARE REQUIRED,EITHER SBCCI OR | | | DADE COUNTY ACCEPTED,WITH THE ASSOCIATED | | | TECHNICAL DRAWINGS. GLAZED OPENINGS THAT | | | HAVN'T RECEIVED APPROVAL FOR LARGE MIS- | | | SLE IMPACT TESTING WILL REQUIRE STORM | | | SHUTTERS WITH THIS APPROVAL. | | | 3)- SBC 1707.4 GLAZED OPENINGS ARE RE- | | | QUIRED TO HAVE TESTING FOR 1 1/2 TIMES | | | THE DESIGN PRESSURE.TESTING TO BE AN | | | APPROVED LABORATORY AND LISTED OR CERTI- | | | FIED FOR COMPLIANCE FOR COMPLIANCE BY A | | | NATIONALLY RECOGNIZED WINDOW/DOOR | | | CERTIFICATION PROGRAM, SBCCI OR DADE | | | COUNTY. | | | | | | 4)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | THE CITY REQUIRES INFORMATION ON THE | | | BUCK ATTACHMENT TO THE CONCRETE COLUMNS | | | AND MASONARY BLOCK UNITS. | | | | | | 5)- FIRE DISTRICT! F102.4 ROOF COVERINGS | | | SHALLCONFORM TO THE REQUIREMENTS OF | | | CLASS A OR B ROOF COVERINGS. | | | | | | 6)- SBC708.5 ROOF INSULATION RATING: | | | FLAME SPREAD RATING & SMOKE DEVELOPMENT. | | | | | | 7)- SBC 1606.3.2: INSULATION FASTENING | | | SCHEDULE FOR THE ROOF. | | | | | | 8)- SBC 606 TYPE IV CONSTRUCTION: NON- | | | COMBUSTIBLE MATERIALS ARE TO BE USED IN | | | THE PARAPET WALL, NO 1/2 " PLYWOOD | | | ALLOWED. SBC 707-(3) DOES ALLOW FIRE RE- | | | TARDANT TREATED WOOD. | | | | | | 9)- SBC 1517 ROOF OVERFLOW SCUPPERS ARE | | | TO BE NO LESS THAN 2" ABOVE THE ROF AND | | | NOT MORE THAN 4" ABOVE THE ROOF SEE PLAN | | | ARCH.4.2. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-08-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-08-21 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-08-21 |
Time |
18:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-03-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-13 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-13 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2001-08-22 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-08-22 |
Time |
08:58 |
Rev Time |
4.00 |
| Received By |
mamini |
Date |
2001-08-22 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2001-08-22 00:00:00 | PASSED : | | | 1. REVISION AS SUBMITTED, APPROVED. | | | NOTE: PLAN WAS REVIEWED AT 45TH, | | | ENGINEERING DEPARTMENT, JOSE DEL RIO. | | | | | | MOHAMMAD R. AMINI 659-8096 EXT. 8492 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2001-05-24 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-05-24 |
Time |
11:39 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2001-05-24 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2001-05-24 00:00:00 | PASSED : | | | 1. RESPONSES TO PREVIOUS REVIEW COMMENTS | | | DATED 5-23-01 SATISFACTORY. CALCULATIONS | | | THAT WAS REQUESTED ARE SUBMITTED TO | | | JOSE DEL RIO, APPROVED. | | | IF ANY QUESTIONS PLEASE CONTACT 695-8096 | | | EXT. 8492 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2001-05-23 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-05-23 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
mamini |
Date |
2001-05-23 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2001-05-23 00:00:00 | FAILED: | | | 1. PLEASE PROVIDE STORM WATER | | | CALCULATINS FOR OUR REVIEW IF YOU HAVE | | | NOT SUBMITTED TO JOSE DEL RIO, STORM | | | WATER ENGINEER AT 1000 45TH STREET WEST | | | PALM BEACH, FL 33407. SEE ATTACHED | | | 2. PLEASE PROVIDE CALCULATIONS FOR | | | PERVIOUS AND IMPERVIOUS AREA FOR ENTIRE | | | SITE DUE TO ALL PROPOSED CHANGES.THE | | | TOTAL AMOUNT MUST BE EQUAL TO 100 % OF | | | TOTAL SITE ACRES OR S.F.THIS DATA WILL | | | BE USED TO CALCULATE STORM WATER CHARGES | | | TO PROPERTY.PROVIDE THIS DATA ON A | | | 8 1/2 X 11 SHEET SIGNED & SEALED BY | | | DESIGN ENGINEER. PLEASE INCLUDE NAME, | | | ADDRESS AND PROPERTY CONTROL NUMBER. | | | 3. ANY NEW CONNECTION TO CITY UTILITY | | | SERVICES REQUIRES A SEPARATE PERMIT | | | THROUGH PUBLIC UTILITIES ENGINEERING | | | SERVICES DEPARTMENT 1000 45TH STREET | | | WEST PALM BEACH, FL 33407. | | | 4. POLLUTION PREVENTION PLAN MUST BE | | | INSTALLED IN THE FIELD PRIOR TO ANY | | | EARTH WORK / DEMOLITIONS WORK.PLANS | | | MUST BE KEPT ON SITE THROUGH OUT THE | | | CONSTRUCTION TIME. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-08-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-08-06 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-08-06 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-03-09 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-03-09 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-03-09 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2001-03-09 00:00:00 | 1) WRONG LIFE SAFETY CODE REFERENCED | | | ON PLANS. SHOULD READ 1985 EDITION | | | INSTEAD OF 1997 EDITION. | | | 2) BUILDING ADDRESS NOT SHOWN ON | | | ELEVATION DRAWINGS. BUILDING ADDRESS | | | TO COMPLY WITH CITY CODE REQUIREMENTS. | | | 3) PROVIDE EXIT MARKINGS AND EMERGENCY | | | LIGHTING. | | | | | | APPROVED PROVISO: | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-09-05 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-05 |
Time |
08:46 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-09-05 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-05-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-05-21 |
Time |
16:41 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-05-21 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-03-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-03-23 |
Time |
09:29 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2001-03-23 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2001-03-23 00:00:00 | ******************PROVISO*************** | | | | | | NO COMBUSTIBLES ABOVE CEILING IN RETURN | | | AIR PLENUM AS PER 1997 SMC 609.1.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-08-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-20 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2001-08-20 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2001-08-20 00:00:00 | DENIED | | | REFERENCE 1994 SPC | | | | | | 1) PAGE P-2 ISLAND SINK DETAIL. | | | SINK NOT VENTED PROPERLY. THIS IS NOT A | | | COMBINATION WASTE AND VENT SYSTEM. WATER | | | CLOSETS ARE NOT ALLOWED. 921.2.1. NOT AN | | | APPROVED SYSTEM. 921.1. VENT DOWN STREAM | | | REQUIRED IF IT WERE APPROVED. 921.4.2 | | | | | | 2) PAGE P3.2 LAV DETAIL. LAV TO MEET | | | FACBC - 97 REQUIREMENT 4.19.2, APRON TO | | | BE 29" FROM FINISHED FLOOR. | | | | | | REVIEW KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-05-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-05-05 |
Time |
12:55 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-05 00:00:00 | PLUMBING PROVISO SEE SHS P-1,3.1,4.2 | | | PES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-03-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-24 |
Time |
13:32 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2001-03-24 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2001-03-24 00:00:00 | DENIED; | | | | | | 1.PAGE CS PLUMBING CODE IS THE 1994 | | | STANDARD PLUMBING CODE NOT 97. | | | | | | 2.AIR CHAMBERS TO COMPLY WITH SPC | | | 607.8.2 AND 607.8.3. | | | | | | 3.WATER HEATER TO BE READLY ACCESSIBLE. | | | CABINET SHALL HAVE A HINGED DOOR. | | | 501.7. | | | | | | 4.DRINFING FOUNTAINS SHALL COMPLY WITH | | | FACBC 4.1.3 (10) AND 4.15 FOR PEOPLE | | | WHO HAVE TROUBLE BENDING AND STOOPING. | | | | | | 5.SHOW CLEAR FLOOR SPACE FOR LAVITORY. | | | BATHROOM DOOR CANNOT SWING INTO CLEAR | | | FLOOR SPACE. SEC. 4.19.3 | | | | | | 6.FLOOR PLAN SHOWS VANITY IN BATHROOM. | | | SHEET 5.1 SHOWS WALL HUNG LAV. LAV. | | | SHALL COMPLY WITH FACBC SEC. 4.19.2. | | | | | | 7.CIVIL DRAWINGS NOT WITH PLANS SUBMITED | | | SHOW WHERE POTABLE WATER COMES FROM | | | AND WHERE RAIN WATER GOES. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2001-08-29 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-08-29 |
Time |
09:30 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-08-29 00:00:00 | APPROVED BY RGRANBERRY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2001-05-24 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-04-20 |
Time |
08:17 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-04-20 00:00:00 | MUST MEET LANDSCAPE REQUIREMENTS |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2001-03-08 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-03-08 |
Time |
07:56 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-08 00:00:00 | NEED APPROVAL OF MINOR AMENDENT BY | | | PLANNING |
|
|