Plan Review Details - Permit 01020769
| Plan Review Stops For Permit 01020769 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-03-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-20 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-20 |
Time |
14:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-03-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-05 |
Time |
19:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-05 |
Time |
19:52 |
Sent To |
|
|
| Notes |
| 2001-03-05 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT PER FL STATUES | | | ALL CHANGES ON PLANS ARE TO BE DONE BY | | | THE ARCH/ENGINEER OF RECORD. ALL | | | CHANGESARE TO BE SIGNED AND DATED. | | | 471.025/ | | | 481.221. | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE, AIC | | | RATING FOR BRKRS SUBMITTED, BUT STILL | | | NEED TO AIC RATINGS FOR ALL EQUIPMENT | | | (MIAN DISCONNECT PER 110-9 AND 215-5. | | | | | | 3) NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. | | | MUST BE 20A AND #12AWG.NEED TO BE SHOWN | | | AS "BATH"S". | | | | | | 4) NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | | PER NFPA-72 2-2.1.1.1. | | | | | | | | | 5)NOTE: PLEASE SEE 210-70 FOR ALL | | | EGRESSLIGHTING REQ`D. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-02-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-02-26 |
Time |
07:17 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2001-02-26 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2001-02-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-02-26 |
Time |
07:17 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2001-02-26 |
Time |
07:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2001-03-21 |
|
|
Cont ID |
|
| Sent By |
lhatten |
Date |
2001-03-21 |
Time |
19:31 |
Rev Time |
4.00 |
| Received By |
lhatten |
Date |
2001-03-08 |
Time |
19:30 |
Sent To |
|
|
| Notes |
| 2001-03-21 00:00:00 | RECEIVED ELECT. CHANGES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-03-22 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-03-22 |
Time |
08:24 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|