Plan Review Details - Permit 01020752
Plan Review Stops For Permit 01020752
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-04-09 Cont ID  
Sent By dpalmer Date 2001-04-09 Time 19:32 Rev Time 0.00
Received By dpalmer Date 2001-04-09 Time 19:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-03-05 Cont ID  
Sent By dpalmer Date 2001-03-05 Time 20:27 Rev Time 0.00
Received By dpalmer Date 2001-03-05 Time 20:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-10-08 Cont ID  
Sent By pkrauss Date 2001-10-08 Time 08:03 Rev Time 0.40
Received By pkrauss Date 2001-10-08 Time 07:45 Sent To  
Notes
2001-10-08 00:00:00MECH REV - CHANGED SOME DUCT SIZES &
 PLAN IS REVERSED FROM ORIGINAL
 SUBMITTAL.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-04-23 Cont ID  
Sent By pkrauss Date 2001-04-23 Time 09:27 Rev Time 0.35
Received By pkrauss Date 2001-04-23 Time 09:21 Sent To  
Notes
2001-04-23 00:00:00MECHANICAL PERMIT 01020754.REVISION -
 CHANGED 3 1/2 TON UNIT TO 5 TON UNT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-02-28 Cont ID  
Sent By jleech Date 2001-02-28 Time 08:42 Rev Time 1.00
Received By jleech Date 2001-02-28 Time 08:42 Sent To  
Notes
2001-02-28 00:00:00DENIED;
  
 1.A/H #2 CFM'S ADD UP TO 2075 3 1/2 NOT
 CAPABLE TO MOVE THAT MUCH AIR.
  
 2.FLOOR PLAN NOT COMPLETE ROOMS MISSING
 AND NOT NAMED. VERY HARD TO FOLLOW.
  
 3.SHOW SIZE AND LOCATION OF EX-FANS,
 VENT SIZE AND TERMINATION POINT.
  
 4.FREON LINES ARE RUN HOW?
  
 A/C PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT.8377

Review Stop P PLUMBING
Rev No 3 Status P Date 2002-01-13 Cont ID  
Sent By pschmitz Date 2002-01-13 Time 08:34 Rev Time 0.50
Received By pschmitz Date   Time   Sent To  
Notes
2002-01-13 00:00:00PLBG REVISION,OK. PES

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-04-20 Cont ID  
Sent By jleech Date 2001-04-20 Time 07:10 Rev Time 0.33
Received By jleech Date 2001-04-20 Time 07:09 Sent To  
Notes
2001-04-20 00:00:00PROVISO; RISER DIAGRAM NOT TO CODE.
 SUBMIT NEW RISER DIAGRAM BEFORE FINAL
 INSPECTION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-02-27 Cont ID  
Sent By jleech Date 2001-02-27 Time 19:23 Rev Time 0.25
Received By jleech Date 2001-02-27 Time 19:23 Sent To  
Notes
2001-02-27 00:00:00PROVISO:
 REVISION FOR SANITARY RISER
 DIAGRAM REQUIRED.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-04-27 Cont ID  
Sent By jgomez Date 2001-04-24 Time 13:39 Rev Time 4.00
Received By jgomez Date 2001-04-24 Time 13:39 Sent To  
Notes
2001-04-24 00:00:00APPROVED WITH PROVISO:
 1-PROVIDE PRODUCT APPROVAL FOR:
 -SLIDING GLASS DOORS.
 2-ARCHITECT TO PROVIDE DETAIL WITH
 COMPLETE SPECIFICATIONS FOR STEEL
 TUBE STRUCTURAL LINTEL AND ANCHORING
 AT ENTRY DOORS ASSEMBLY.
 SEC. 104.2.2 CITY AMENDMENTS TO SBC/97
 3-TRUSS DRAWINGS (SECOND CHECKLIST):
 -TRUSS DRAWINGS TO CLEARLY SPECIFY THE
 CODE EDITION USED FOR DESIGN. IN THIS
 CASE IT'S SBC 1997.
 -UPDATE ALL GENERAL TRUSS DRAWINGS
 AND LETTERS. FOLLOW CHAPTER 471 OF
 FLORIDA STATUTES REQUIREMENTS.
 -TRUSS ENGINEER TO PROVIDE ALL HIS
 INFORMATION AS REQUIRED BY CHAPTER
 471 OF FLORIDA STATUTES.
 4-DESIGNER OF RECORD TO REVIEW ALL TRUSS
 DRAWINGS PRIOR TO SUBMITTAL TO THIS
 OFFICE.
 5-REVISE MEAN ROOF HEIGHT AS REQUIRED.
 SEE BUILDING HEIGHT DEFINITION FROM
 SBC 1997. ATTACHED.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ AT 659-8096 EXT. 8232.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-03-17 Cont ID  
Sent By jgomez Date 2001-03-17 Time 12:12 Rev Time 3.00
Received By jgomez Date 2001-03-17 Time 12:12 Sent To  
Notes
2001-03-17 00:00:00CHECKLIST:
 1-PAY IMPACT FEES.
 2-NEED NOTICE OF COMMENCEMENT. (NOC)
 3-SPECIFY DRAFSTOPPING MATERIAL AND
 LOCATION AT 2ND FLOOR FRAMING PLAN.
 SEC. 2305.2 SBC 1997.
 4-PROVIDE CURRENT SBCCI OR DADE COUNTY
 PRODUCT APPORVAL FOR:
 -OUTSWING ENTRY DOORS W/ TRANSOM ABOVE
 ASSEMBLY AS SHOWN ON EXTERIOR ELEVAT'N
 -FIXED WINDOWS W/ SIZE SHOWN ON PLANS.
 -GARAGE DOORS THAT MEET THE DESIGN
 PRESSURES CALCULATED BY THE ARCHITECT.
 -ROUND WINDOWS AS SHOWN ON PLANS.
 -BBQ UL LISTING AND SPECIFICATIONS.
 5-SIZE OF EGRESS WINDOW AT BEDROOM #3
 DOESN'T MEET THE MINIMUM SIZE AS
 REQUIRED BY SEC 1005.4.4 SBC 1997.
 6-SPECIFY SAFETY GLASS WHERE REQUIRED.
 2405.2 SBC/97. SEE PLANS FOR COMMENTS.
 7-PROVIDE COMPLETE STAIR DETAIL/SECTION
 THAT APPLIES TO THIS HOUSE. SEE PLANS.
 SEC. 104.2.2 CITY AMENDMENTS TO
 SBC/978-REVISE INSTALLATION
 SPECIFICATIONS FOR
 CEILING AT EXTERIOR PORCHES. SEE
 ASTM C 1063 AND PROVIDE COMPLETE
 SPECS9-SPECIFY HOW IS ROOF CROSS
 VENTILATION
 ACHIEVED IF ATTIC VENTS ARE CLOSED AT
 ZERO LOT LINE WALL. SEC 2309.6 SBC/97.
 10-FOOTINGS TO BE 12" MIN. BELOW GRADE.
 SEC 1804.1.3 SBC/97. REVISE SECTIONS.
 11-SOIL TEST REPORT MUST HAVE ENGINEER'S
 ORIGINAL SIGNATURE AS REQUIRED BY
 CHAPTER 471 OF FLORIDA STATUTES.
 12-REVISE ENERGY CALCULATIONS. THERE ARE
 4 BEDROOMS, CONSIDERING THE DEN ROOM.
 13-STORM PANELS: PROVIDE KEY PLAN AND
 COMPLETE INSTALLATION SCHEDULE (SEE
 ATTACHED CITY SAMPLE).
 -CLEARLY INDICATE ON DRAWINGS THE
 MOUNTING SYSTEMS TO BE USED AND ANCHOR
 TYPE AND SPACING TO BE USED ACCORDING
 TO THE MEAN ROOF HEIGHT, THE DESIGN
 PRESSURES, PANEL SPAN, EDGE DISTANCE,
 CONNECTION TYPE AND STRUCTURE TO BE
 ATTACHED TO (CONCRETE BLOCK OR WOOD).
 14-REVISE TRUSS DRAWINGS:
 -THERE IS ONLY ONE MEAN ROOF HEIGHT FOR
 ENTIRE BUILDING. TABLE 1606.2A SBC/97.
 SEE ARCHITECT'S PLANS.
 -EDITION OF THE STANDARD BUILDING CODE
 1997 IS WRITTEN BY HAND. THIS IS NOT
 ACCEPTABLE. IT SHOULD BE PART OF THE
 COMPUTER PROGRAM.
 -UPDATE ALL GENERAL TRUSS DRAWINGS AND
 ENGINEER TO DATE THEM W/ THE DATE HE
 SEALED AND SIGNED THEM AS REQUIRED BY
 CHAPTER 471 OF FLORIDA STATUTES.
 -ALL TRUSS DRAWINGS SHALL BE REVIEWED
 BY THE ARCHITECT PRIOR TO SUBMITTAL.
 -TRUSS LAYOUT IS MISSING 2ND FL. ROOF.
 -TRUSS ENGINEER TO PROVIDE ALL HIS
 INFORMATION AS REQUIRED BY CHAPTER
 471 OF FLORIDA STATUTES WHEN SUBMITT'G
 DOCUMENTS FOR PUBLIC RECORDS.
 15-SEE PLANS FOR ADDITIONAL COMMENTS.
 -SEE COMMENTS BY THE OTHER TRADES.
  
  
  
 * IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ, BUILDING PLAN REVIEWER,
 AT 659-8096 EXT. 8232.

Review Stop Z ZONING
Rev No 1 Status P Date 2001-02-21 Cont ID  
Sent By sgraham Date 2001-02-21 Time 12:55 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***