| Plan Review Stops For Permit 01020616 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-02-20 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-02-20 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-04-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-17 |
Time |
20:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-17 |
Time |
20:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2001-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-01 |
Time |
18:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-01 |
Time |
18:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-03-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-03-05 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-04-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-04-06 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-04-06 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2001-04-06 00:00:00 | 1) THE FIRE RESCUE DEPARTMENT HAS | | | RECEIVED A LETTER INDICATING THAT NO | | | COOKING THAT PRODUCES SMOKE OR GREASE | | | LADEN VAPORS WILL BE CONDUCTED ON SITE. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-03-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-03-05 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-03-05 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2001-03-05 00:00:00 | 1) PROVISIONS ARE TO BE MADE FOR AT | | | LEAST TWO HANDICAPPED PERSONS. | | | 2) PROVIDE LETTER TO THIS OFFICE | | | INDICATING THAT NO COOKING THAT | | | PRODUCES SMOKE OR GREASE LADEN VAPORS | | | WILL BE DONE ON THE PREMISES. | | | 3) PROVIDE PERMIT AND SHOP DRAWINGS FOR | | | FIRE SPRINKLER REMODEL. | | | 4) EXIT SIGN LOCATED NEAR BATHROOMS IS | | | TO BE LOCATED DIRECTLY ADJACENT TO EXIT | | | DOORS. | | | 5) TENANT SPACE MUST HAVE FIRE ALARM | | | DEVICES THAT ACTIVATE WHEN THE BUILDINGS | | | FIRE SPRINKLER OR FIRE ALARM SYSTEM | | | ACTIVATES. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-04-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-04-11 |
Time |
12:42 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-04-11 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2001-04-11 00:00:00 | ******************PROVISIO************** | | | | | | AUXILIARY DRAIN PAN SHALL HAVE OVERFLOW | | | PROTECTION BY MEANS OF A FLOAT SWITCH | | | OR SEPARATE DRAIN LINE AS PER 1997 SMC | | | 304.8.6.1. | | | | | | PLEASE PROVIDE DETAIL OF REFRIGERANT | | | LINES GOING FROM CONDENSER TO AHU. | | | PLEASE ADDRESS THE ABOVE ITEMS WHEN THE | | | MECHANICAL PERMIT IS APPLIED FOR. | | | | | | ADDITIONAL MECHANICAL PERMIT REQUIRED | | | FOR WALKIN COOLER.PLEASE SUBMIT PLANS | | | WITH PERMIT APPLICATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2001-03-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-03-01 |
Time |
16:36 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-03-01 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2001-03-01 00:00:00 | ******************DENIED**************** | | | | | | CONDENSERS UNPROTECTED IN A PARKING | | | GARAGE, SPOKE WITH ENGINEER OF RECORD, | | | LINE SETS WOULD HAVE BEEN TO FAR FOR | | | MOUNTING OF THE CONDENSER WHERE | | | ORIGINAL BUILDING PLANS CALL FOR | | | CONDERSERS TO BE MOUNTED. | | | | | | CONDENSATE LINE TO BE PIPED TO NEAREST | | | STORM DRAIN...NO INDICATION AS TO WHERE | | | THAT MIGHT BE. | | | | | | ENGINEER NEEDS TO PROVIDE DETAIL TO | | | PROTECT CONDENSERS FROM DAMAGE/SAFETY. | | | | | | ADDITIONAL PERMITS REQUIRED FOR WALKIN | | | COOLERS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-07-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-07-07 |
Time |
13:35 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2001-07-07 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-06-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-06-23 |
Time |
14:25 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2001-06-23 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2001-06-23 00:00:00 | DENIED; | | | | | | ITEMS 1 THRU 3 ARE STILL NOT | | | COMPLETE; | | | | | | 1.CONTACT RODNEY COMPO AT 837-4074 FOR | | | GREASE TRAP WAVER LETTER AND SHOW | | | LOCATION OF SAMPLE POINT ON PLANS. | | | | | | 2.WATER HEATER TO BE READILY ACCESSIBLE | | | REFUR TO THE 94 SPC CHAPTER 2 | | | DEFINITIONS. | | | | | | 3.SHT P-1 ITEMS 34 AND 35 TO DRAIN INTO | | | A FLOOR SINK. CHANGED ON RISER DIAGRAM | | | BUT NOT ON PLUMBING PLAN. | | | | | | PLUMBING PLAN REVIEW BY | | | JOHN LEECH | | | 659-8096 EXT. 8369 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-04-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-04-19 |
Time |
12:06 |
Rev Time |
1.50 |
| Received By |
jleech |
Date |
2001-04-19 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2001-04-19 00:00:00 | DENIED; | | | | | | NOTES ARE THE SAME AS LAST REVIEW | | | | | | 1.CONTACT RODNEY COMPO AT 837-4074 FOR | | | GREASE TRAP WAVER AND LOCATION FOR | | | SAMPLE POINT. | | | | | | 2.WATER HEATER; READ DEFINITION FOR | | | READLY ACCESSIBLE. CHAPTER 2 OF THE 94 | | | SPC PROVIDE FIXED LADDER. 501.7 | | | | | | 3.CONDENSATE FROM COOLERS SHALL | | | TERMINATE TO A FLOOR SINK NOT A FLOOR | | | DRAIN. | | | | | | 4.PLEASE ADD A NOTE; IF AIR CHAMBERS ARE | | | USED THEY WILL COMPLY WITH 607.8.2 AND | | | 607.8.3. | | | | | | PLUMBINGPLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-03-04 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-03-04 |
Time |
10:06 |
Rev Time |
1.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-04 00:00:00 | PLUMBING PLAN REVIEWDENIED | | | (1) LETTER FRON CHARLOTTE RUSSELL RE: | | | GREASE TRAP, CONTACT,RODNEY COMPO | | | 561-835-7423 W P BCH REGIONAL SEWER | | | TREATMENT PLANT FOR GREASE TRAP WEAVER, | | | WITH LOCATION OF SAMPLE POINT. | | | (2) SHT P-1 WATER HEATER TO BE READLY | | | ACCESSIBLE SPC 94 SEC 501.7 PROVIDE A | | | DETAIL OF A WORKING PLATFORM WITH A | | | SHIPS LADDER FIXED IN PLACE. | | | (3) SHT P-1 ITEMS 34,35 ALL INDIRECT | | | WASTE TO FLOOR SINKS SEC 802. | | | (4) SHT P-1 AIR CHAMBERS, COMPLY WITH | | | SEC.607.8.3,ACCESSIBLE & RE-CHARGE-ABLE. | | | END OF COMMENTS PAUL SCHMITZ | | | QUESTIONS561-659-8096 X 8233 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-03-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-03-05 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|