Plan Review Details - Permit 01020616
Plan Review Stops For Permit 01020616
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-02-20 Cont ID  
Sent By hpiskura Date 2001-02-20 Time 15:41 Rev Time 0.00
Received By hpiskura Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-04-17 Cont ID  
Sent By dpalmer Date 2001-04-17 Time 20:50 Rev Time 0.00
Received By dpalmer Date 2001-04-17 Time 20:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-03-01 Cont ID  
Sent By dpalmer Date 2001-03-01 Time 18:42 Rev Time 0.00
Received By dpalmer Date 2001-03-01 Time 18:42 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2001-03-05 Cont ID  
Sent By lmartine Date 2001-03-05 Time 14:34 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-04-06 Cont ID  
Sent By mcarsill Date 2001-04-06 Time 13:49 Rev Time 0.00
Received By mcarsill Date 2001-04-06 Time 13:49 Sent To  
Notes
2001-04-06 00:00:001) THE FIRE RESCUE DEPARTMENT HAS
 RECEIVED A LETTER INDICATING THAT NO
 COOKING THAT PRODUCES SMOKE OR GREASE
 LADEN VAPORS WILL BE CONDUCTED ON SITE.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-03-05 Cont ID  
Sent By mcarsill Date 2001-03-05 Time 14:19 Rev Time 0.00
Received By mcarsill Date 2001-03-05 Time 14:18 Sent To  
Notes
2001-03-05 00:00:001) PROVISIONS ARE TO BE MADE FOR AT
 LEAST TWO HANDICAPPED PERSONS.
 2) PROVIDE LETTER TO THIS OFFICE
 INDICATING THAT NO COOKING THAT
 PRODUCES SMOKE OR GREASE LADEN VAPORS
 WILL BE DONE ON THE PREMISES.
 3) PROVIDE PERMIT AND SHOP DRAWINGS FOR
 FIRE SPRINKLER REMODEL.
 4) EXIT SIGN LOCATED NEAR BATHROOMS IS
 TO BE LOCATED DIRECTLY ADJACENT TO EXIT
 DOORS.
 5) TENANT SPACE MUST HAVE FIRE ALARM
 DEVICES THAT ACTIVATE WHEN THE BUILDINGS
 FIRE SPRINKLER OR FIRE ALARM SYSTEM
 ACTIVATES.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-04-11 Cont ID  
Sent By pkrauss Date 2001-04-11 Time 12:42 Rev Time 0.30
Received By pkrauss Date 2001-04-11 Time 12:24 Sent To  
Notes
2001-04-11 00:00:00******************PROVISIO**************
  
 AUXILIARY DRAIN PAN SHALL HAVE OVERFLOW
 PROTECTION BY MEANS OF A FLOAT SWITCH
 OR SEPARATE DRAIN LINE AS PER 1997 SMC
 304.8.6.1.
  
 PLEASE PROVIDE DETAIL OF REFRIGERANT
 LINES GOING FROM CONDENSER TO AHU.
 PLEASE ADDRESS THE ABOVE ITEMS WHEN THE
 MECHANICAL PERMIT IS APPLIED FOR.
  
 ADDITIONAL MECHANICAL PERMIT REQUIRED
 FOR WALKIN COOLER.PLEASE SUBMIT PLANS
 WITH PERMIT APPLICATION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-03-02 Cont ID  
Sent By pkrauss Date 2001-03-01 Time 16:36 Rev Time 0.45
Received By pkrauss Date 2001-03-01 Time 15:56 Sent To  
Notes
2001-03-01 00:00:00******************DENIED****************
  
 CONDENSERS UNPROTECTED IN A PARKING
 GARAGE, SPOKE WITH ENGINEER OF RECORD,
 LINE SETS WOULD HAVE BEEN TO FAR FOR
 MOUNTING OF THE CONDENSER WHERE
 ORIGINAL BUILDING PLANS CALL FOR
 CONDERSERS TO BE MOUNTED.
  
 CONDENSATE LINE TO BE PIPED TO NEAREST
 STORM DRAIN...NO INDICATION AS TO WHERE
 THAT MIGHT BE.
  
 ENGINEER NEEDS TO PROVIDE DETAIL TO
 PROTECT CONDENSERS FROM DAMAGE/SAFETY.
  
 ADDITIONAL PERMITS REQUIRED FOR WALKIN
 COOLERS.

Review Stop P PLUMBING
Rev No 4 Status P Date 2001-07-07 Cont ID  
Sent By jleech Date 2001-07-07 Time 13:35 Rev Time 0.75
Received By jleech Date 2001-07-07 Time 13:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2001-06-23 Cont ID  
Sent By jleech Date 2001-06-23 Time 14:25 Rev Time 1.00
Received By jleech Date 2001-06-23 Time 14:25 Sent To  
Notes
2001-06-23 00:00:00DENIED;
  
 ITEMS 1 THRU 3 ARE STILL NOT
 COMPLETE;
  
 1.CONTACT RODNEY COMPO AT 837-4074 FOR
 GREASE TRAP WAVER LETTER AND SHOW
 LOCATION OF SAMPLE POINT ON PLANS.
  
 2.WATER HEATER TO BE READILY ACCESSIBLE
 REFUR TO THE 94 SPC CHAPTER 2
 DEFINITIONS.
  
 3.SHT P-1 ITEMS 34 AND 35 TO DRAIN INTO
 A FLOOR SINK. CHANGED ON RISER DIAGRAM
 BUT NOT ON PLUMBING PLAN.
  
 PLUMBING PLAN REVIEW BY
 JOHN LEECH
 659-8096 EXT. 8369

Review Stop P PLUMBING
Rev No 2 Status F Date 2001-04-19 Cont ID  
Sent By jleech Date 2001-04-19 Time 12:06 Rev Time 1.50
Received By jleech Date 2001-04-19 Time 12:06 Sent To  
Notes
2001-04-19 00:00:00DENIED;
  
 NOTES ARE THE SAME AS LAST REVIEW
  
 1.CONTACT RODNEY COMPO AT 837-4074 FOR
 GREASE TRAP WAVER AND LOCATION FOR
 SAMPLE POINT.
  
 2.WATER HEATER; READ DEFINITION FOR
 READLY ACCESSIBLE. CHAPTER 2 OF THE 94
 SPC PROVIDE FIXED LADDER. 501.7
  
 3.CONDENSATE FROM COOLERS SHALL
 TERMINATE TO A FLOOR SINK NOT A FLOOR
 DRAIN.
  
 4.PLEASE ADD A NOTE; IF AIR CHAMBERS ARE
 USED THEY WILL COMPLY WITH 607.8.2 AND
 607.8.3.
  
 PLUMBINGPLAN REVIEW BY;
 JOHN LEECH
 659-8096

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-03-04 Cont ID  
Sent By pschmitz Date 2001-03-04 Time 10:06 Rev Time 1.50
Received By pschmitz Date   Time   Sent To  
Notes
2001-03-04 00:00:00PLUMBING PLAN REVIEWDENIED
 (1) LETTER FRON CHARLOTTE RUSSELL RE:
 GREASE TRAP, CONTACT,RODNEY COMPO
 561-835-7423 W P BCH REGIONAL SEWER
 TREATMENT PLANT FOR GREASE TRAP WEAVER,
 WITH LOCATION OF SAMPLE POINT.
 (2) SHT P-1 WATER HEATER TO BE READLY
 ACCESSIBLE SPC 94 SEC 501.7 PROVIDE A
 DETAIL OF A WORKING PLATFORM WITH A
 SHIPS LADDER FIXED IN PLACE.
 (3) SHT P-1 ITEMS 34,35 ALL INDIRECT
 WASTE TO FLOOR SINKS SEC 802.
 (4) SHT P-1 AIR CHAMBERS, COMPLY WITH
 SEC.607.8.3,ACCESSIBLE & RE-CHARGE-ABLE.
 END OF COMMENTS PAUL SCHMITZ
 QUESTIONS561-659-8096 X 8233

Review Stop Z ZONING
Rev No 1 Status N Date 2001-03-05 Cont ID  
Sent By lmartine Date 2001-03-05 Time 14:35 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***