Plan Review Details - Permit 01020521
| Plan Review Stops For Permit 01020521 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-04-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-03 |
Time |
15:38 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-04-03 00:00:00 | BUILDING ISSUE DATE 2/14 BY MISTAKE JW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-05-08 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-05-08 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-04-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-06 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-06 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2001-04-06 00:00:00 | ******************** UNSAT ************ | | | | | | 1)NOTE:PLANS NEED TO HAVE BRANCH | | | CIRCUIT#`S NEED TO BE SHOWN ON PLANS | | | ANDSUBMIT PANEL SCHEDULE THAT | | | CORRELATESWITH #`S ON PLANS. | | | | | | 2)NOTE: PLANS SHOW NEW ADDED LOAD. WHAT | | | ABOUT EXSITING LOAD? | | | ALSO PLANS SHOW ADDING CIRCUITS TO | | | PANELIN ADJACENT SPACE. THIS IS NOT | | | PERMITTED | | | | | | 3) PLEASE NOTE MISSING OUTLET FOR A/C | | | EQUIPMENT PER 210-63 OF NEC AND 309.1 | | | MECHANICAL CODE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-03-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-03-30 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-03-30 |
Time |
10:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-05-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-05-09 |
Time |
16:44 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-05-09 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2001-04-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-04-03 |
Time |
11:06 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-04-03 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2001-04-03 00:00:00 | *******************DENIED*************** | | | | | | | | | MECHANICAL PERMIT REQUIRED. PLANS NEED | | | TO INDICATE CONDENSATE DRAIN LINE. | | | ALSO AN AUXILIARY DRAIN PAN WITH | | | OVERFLOW PROTECTION REQUIRED AS PER | | | 1997 SMC 304.8.6. | | | | | | NOTE 5 ON THE AIR CONDITIONING | | | SPECIFICATION, INDICATES 105 CFM MAKE | | | UP VENTALATION AIR,PLANS NEED TO | | | REFLECT LOCATION OF MAKE UP AIR.SHOW | | | O.A. CALCULATION AS PER ASHRAE 62-89. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-02-14 |
|
|
Cont ID |
|
| Sent By |
ydavis |
Date |
2001-02-14 |
Time |
08:31 |
Rev Time |
0.25 |
| Received By |
ydavis |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-14 00:00:00 | 2/14/01 OKAY PER RYAN N. YD |
|
|
|