Plan Review Details - Permit 01020116
Plan Review Stops For Permit 01020116
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2001-03-27 Cont ID  
Sent By jwitmer Date 2001-03-27 Time 15:40 Rev Time 0.33
Received By jwitmer Date   Time   Sent To  
Notes
2001-03-27 00:00:00REVISION 3/26/01 UNSAT: ARCHITECTS PLANS
 REQUIRE RAISED SEAL & SIGNED BY THE
 ARCHITECT OF RECORD. J WITMER 3/27/01

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-03-20 Cont ID  
Sent By jwitmer Date 2001-03-20 Time 10:45 Rev Time 1.50
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-02-14 Cont ID  
Sent By jwitmer Date 2001-02-14 Time 10:02 Rev Time 3.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-02-14 00:00:00PERMIT # 01020116
 O/B BRINKMAN, MARK
 381 CHURCHILL RD.
  
 1)- PERMIT FEES:CALCULATED FEES FOR ADD-
 ITION GOOD VALUATION $38,489.00,
 AVERAGE VALUATION $27,456.00, FOR ADDI-
 TIONS THE AVERAGE VALUATIONIS $27,456.
 2)- BEFORE THE BUILDING PERMIT WILL BE
 ISSUED THE OWNER WILL BE REQUIRED TO
 PAY COUNTY IMPACT FEES (WITH PLANS) AT
 THE COUNTY BUILDING DEPARTMENT.
 3)- SBC 104.2.2 AMEND.- (2) SIGNED &
 SEALED SURVEYS WILL BE REQUIRED.
 4)- FL ENERGY EFFICIENCY CODE 400.ABCD.2
 THE BUILDING'S OWNER, THE OWNER'S
 ARCHITECT, OR OTHER AUTHORIZED AGENT
 LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY TO THE BUILDING OFFICIAL THAT
 THE BUILDING IS IN COMPLIANCE WITH THE
 ENERGY EFFICIENTY CODE.
 5)- SBC 104.2.2- ADDITIONAL INFORMATION
 MISSING DETAIL 1/A-1, NO INFORMATION ON
 FOUNDATION, UP-RIGHT STEEL SIZE OR SPAC-
 ING, TYPE OF BEAM, BOND BEAMOR BEAM
 BLOCK, CONCRETE MIX OR GROUT ETC?
 6)- SOIL BEARING VALUE? SBC 2304.1.2
 7)- SBC 2304.1.2 TERMITE TREATMENT OF
 SOIL, VAPOR BARRIER BEFORE SLAB TO BE
 POURED.
 8)- SBC 104.2.2- ADDITIONAL INFORMATION
 UPLIFT TO BE GIVEN FOR ROOF FRAMING
 MEMBERS INCLUDING INFORMATION ON THE
 PORCH. THE CONVENTIONAL FRAMED ROOF,
 WHAT LIVE AND DEAD LOADS ARE BEING
 IMPOSED? SPECIES OF WOOD AND GRADE?
 9)- GAGLE END BRACING DETAILS?
 10)_ MISSING INFORMATION ON THE MINIMUM
 ROOF SHEATHING?
 11)- MISSING INFORMATION ON THE BRICK
 VENEER ATTACHMENT TO THE MASONARY WALL
 AND THE ATTACHMENT OF BRICK OVER THE
 WINDOW OPENINGS. SBC 1403.2.6.
 12)- SBC 2806.1.2- FACTORY BUILT FIRE-
 PLACES SHALL BE TESTED IN ACCORDANCE
 WITH AND MEET THE REQUIREMENTS OF UL-127
 HEARTH EXTENSIONS, MAKE UP AIR,ETC. A
 COPY OF THE MANUFACTURES SPECS(2) COPIES
 13)- DETAILS ON THE STEEL FRAMED CHIMNEY
 THE STEEL GAUGE FOR STRUCTURAL COMPONENT
 THE DESIGN OF THE CHIMNEY, THE TIE DOWN
 TO THE ROOF FRAMING MEMBERS, CHIMNEY
 LINING, AND RAIN CAP AND ATTACHMENT.
 14)- DETAILS ON THE BAY WINDOW DETAIL
 #4 MISSING, SILL,COLUMNS,TIE DOWNS,AND
 ROOF FRAMING ATTACHMENT WITH BRICK
 VENEER ABOVE WITH STEP FLASHING.
 15)- SBC 1606.2.6.2- COMPONENTS & CLADD-
 ING: BUCK ATTACHMENT FOR WINDOWS.
 16)- PRODUCT APPROVAL FOR ALL WINDOWS,
 SINGLE HUNG WEST ELEVATION, FOR WIND
 REQUIREMENTS.
 17)- SBC 1503.3.2 AMEND ASPHALT SHINGLES
 ARE TO HAVE PRODUCT TESTING FOR 110MMPH
 WIND ZONE. DADE COUNTY OR SBCCI REPORT
 ACCEPTED.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-03-12 Cont ID  
Sent By dpalmer Date 2001-03-12 Time 12:53 Rev Time 0.00
Received By dpalmer Date 2001-03-12 Time 12:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-02-09 Cont ID  
Sent By dpalmer Date 2001-02-09 Time 12:55 Rev Time 0.00
Received By dpalmer Date 2001-02-09 Time 12:55 Sent To  
Notes
2001-02-09 00:00:00***************UNSAT *******************
  
 1)NOTE: PLEASE NOTE UNDER 220-3-C-1
 PLEASE SUBMIT LOAD CALCULATIONS AND SHOW
 SIZE OF EXISTING SERVICE.
  
 PLEASE SUBMIT THE ABOVE INFORMATIONFOR
 REVIEW. IF THERE ARE ANY QUESTIONS PLEAS
 E CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-03-07 Cont ID  
Sent By pkrauss Date 2001-03-07 Time 11:15 Rev Time 0.00
Received By pkrauss Date 2001-03-07 Time 11:17 Sent To  
Notes
2001-03-01 00:00:00NOTE:AUXILLIARY DRAIN PAN W/FLOAT
 SWITCH OR DRAIN LINE REQUIRED - 1997
 SMC 304.8.6.1.
  
 AREAS WITH 300 CFM OR GREATER, REQUIRE
 R/A FROM AREA.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-02-08 Cont ID  
Sent By jleech Date 2001-02-08 Time 08:06 Rev Time 0.50
Received By jleech Date 2001-02-08 Time 08:06 Sent To  
Notes
2001-02-08 00:00:00DENIED;
  
 1.NOT ENOUGH INFORMATION. SHOW A/C
 EQUIPMENT SIZE AND AREA OF EXISTING
 HOUSE. YOU ARE ADDINGV 1 1/2 TONS OF
 AIR WITH NEW ADDITION.
  
 2.NOTES:
 8.NO EQUIPMENT LISTED.
 12.1" DUCT BOARD IS NOT PERMITED IN
 UNCONDITIONED SPACE. ALSO
 DRAWINGS SHOW ROUND DUCT NOT
 DUCT BOARD.
  
 ANY QUESTIONS CALL
 JOHN LEECH
 659-8096 EXT. 8377

Review Stop P PLUMBING
Rev No 1 Status N Date 2001-03-20 Cont ID  
Sent By jwitmer Date 2001-03-20 Time 10:44 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-02-08 00:00:00NO PLUMBING IN ADDITION

Review Stop Z ZONING
Rev No 1 Status P Date 2001-02-07 Cont ID  
Sent By sgraham Date 2001-02-07 Time 09:43 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***