| Plan Review Stops For Permit 01020102 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2002-09-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-09-04 |
Time |
13:53 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2002-09-04 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2002-09-04 00:00:00 | SUBMITTAL: BAR JOIST REPAIR, SUBSTITU- | | | TION BOLTS TO WELD & FIELD MODIFICATION | | | CONNECTION @ EMBED BEARING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2002-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-08-07 |
Time |
17:02 |
Rev Time |
0.25 |
| Received By |
jwitmer |
Date |
2002-08-07 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2002-08-07 00:00:00 | | | | BUILDING PLAN REVIEW | | | PERMIT: 01020102 | | | ADD: 1801 OKEECHOBEE ROAD | | | CONT: CATALFUMO | | | TEL: (561)233-7960 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | FL BLDG CODE COUNTY AMENDMENTS 104.1.1: | | | SIGNS SHALL REQUIRE SEPERATE PERMITS. | | | A PERMIT SHALL BE REQUIRED FOR EVERY | | | ELEVATION OF THE BUILDING, A SEPERATE | | | SIGN PERMIT FOR MONUMENT SIGNS SEE | | | CITY ORDINANCE FOR ADDRESS RANGE TO BE | | | ON ALL MONUMENT SIGNS!!! | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS, OR ATTACHED | | | SEPARATELY. WHEN RESUBMITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION AND | | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | | ARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION MADE, IDEN- | | | TIFYING THE SHEET OR SPECIFICATION PAGE | | | WHERE THE CHANGES CAN BE FOUND, WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | JIM WITMER | | | PLAN REVIEW | | | TEL: (561)659-8096 EX.8412 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2002-06-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-06-11 |
Time |
17:19 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-06-11 00:00:00 | PRODUCT TESTING REPORTS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2002-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-04-30 |
Time |
14:34 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-04-30 00:00:00 | REVISION: STEEL WWLD PLATE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2002-02-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2002-02-08 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2002-02-08 00:00:00 | SHOP DRAWINGS STRUCTURAL STEEL BLDG #1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2001-11-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-26 |
Time |
17:59 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-26 00:00:00 | REVISION DATED 10/30/01 OF'EDJW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-09-18 |
Time |
15:05 |
Rev Time |
5.00 |
| Received By |
hpiskura |
Date |
2001-09-18 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01020102 | | | 1801 OKEECHOBEE RD / 1705 | | | TYPE IV / PROTECTED | | | FULLY SPRINKLERED | | | OCCUPANCY: STORAGE | | | | | | FL. STATE STATUTE 553. CHAPTER 468 | | | PART XII, CHAPTER 7 OF THE CITY CODE | | | REQUIRE A RESIDENT INSPECTOR ON THE JOB | | | SITE. TO DATE THE INTERVIEW BETWEEN THE | | | RESIDENT JOB SITE INSPECTOR AND THE | | | ASSISTANT BUILDING OFFICIAL. | | | | | | MISSING ARE (2) COPIES OF A SURVEY. CITY | | | HAS (1) SEAL SURVEY. | | | | | | PLANS ARE TO GO TO THE COUNTY FOR | | | COUNTY IMPACT FEES.PLANS WILL BE STAMPED | | | AND A COPY OF RECEIPT TO BE ATTACHED TO | | | THE APPLICATION. | | | | | | CONTRACTOR TO PAY STATE RADON FEES & | | | COPING FEES OF $1,058.22. | | | | | | | | | WE WILL BE ABLE TO ISSUE THE BUILDING | | | AND SUBPERMITS ONCE THIS LIST HAS BEEN | | | COMPLETED!!!!! | | | | | | JIM WITMER | | | PLAN REVIEW | | | (561) 659-8096 X 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2001-08-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-08-30 |
Time |
06:45 |
Rev Time |
3.50 |
| Received By |
jwitmer |
Date |
2001-08-30 |
Time |
06:45 |
Sent To |
|
|
| Notes |
| 2001-08-30 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT # 01020102 | | | 1801 OKEECHOBEE ROAD / 1701 BLDG# 1 | | | TYPE IV / PROTECTED | | | FULLY SPRINKLERED | | | OCCUPANCY: STORAGE | | | OWNER: PREMIER AIRPORT CENTER, LLP | | | | | | 1)- FL. STATE STATUTE 553 / CHAPTER 468 | | | PART XII CHAPTER 7 OF THE CITY CODE & | | | THE SBC REQUIRE A RESIDENT INSPECTOR ON | | | THE SITE. TO DATE NO COMPANY AND INDIVID | | | UAL HAS MET WITH THE ASSISTANT BUILDING | | | OFFICIAL DON NEELY TO REGISTER IN THE | | | PROGRAM. THE INSPECTOR IS REQUIRED TO | | | SHOW STATE LICENSURE. | | | | | | 2)_ ROOF DECK : THE JOB SITE IS LOCATED | | | IN A FIRE DISTRICT, SHOW MANUFACTURES | | | SPECIFICATION FOR A CLASS A OR B ROOFING | | | SYSTEM. | | | | | | 3)- ROOF DECK (SYSTEM) SBC 1503.3.2 ROOF | | | ING SYSTEMS ARE TO BE TESTED FOR THE WIN | | | D ZONE THAT THE BUILDING IS LOCATED IN. | | | 110MPH WIND ZONE, SHOW COMPLIANCE EITHER | | | SBCCI REPORT OR DADE COUNTY, IF NOT | | | PROVIDED AT TIME OF PERMIT THE ROOFING | | | PERMIT WILL BE STRUCK & THE CONTRACTOR | | | WILL HAVE TO COME IN UNDER SEPERATE PER- | | | MIT WITH REPORT & PAY ADDITIONAL PERMIT | | | FEES. | | | | | | 4)- SBC 104.2.2 ADDITIONAL INFORMATION | | | REQUIRED. A CURRENT SURVEY WILL BE RE- | | | QUIRED. | | | THE SITE IS LOCATED IN A (A-9) | | | FLOOD ZONE. THE MINIMUM ELEVATION HEIGTH | | | IS 13'-6" FOR THE FINISH SLAB. A ELEVATI | | | ON CERTIFICATE WILL BE REQUIRED BEFORE | | | THE C. O. WILL BE ISSUED. | | | | | | 5)- SBC COMPONENTS & CLADDING THE PLANS | | | DEPICT THAT THERE WILL BE NO SUB-BUCK | | | FOR WINDOWS & DOORS. THERE SEEMS TO BE | | | NO DETAIL FOR THE OVERHEAD DOOR. | | | | | | 6)- SBC 1606.4.1/ 1707.4.1 AMENDMENTS | | | ALL GLAZED OPENINGS REQUIRE PRODUCT TEST | | | ING REPORTS!!!!!!!!!!! TESTING REPORTS | | | REGAURDLESS OF SHUTTERS IS REQUIRED FOR | | | WIND SBC 1707.4.1 10 SECOND TEST EQUAL | | | TO 1.5 TIMES THE DESIGN LOAD. THIS IS | | | FOR GLASS DOORS, WINDOWS & SKYLIGHTS!!!! | | | | | | 7)- SBC 1606.4.1 /1707.4.1 ALL GLAZED OP | | | ENINGS WILL REQUIRE PRODUCT TESTING FOR | | | LARGE MISSLE IMPACT TESTING. GLAZED OPEN | | | INGS THAT HAVEN'T BEEN TESTE FOR THIS | | | WILL REQUIRE STORM SHUTTER PROTECTION. | | | THE CITYS' OFFICIAL INTERPRETATION | | | FOR MISSLE IMPACT PROTECTION HAS A SEC- | | | TION (#14) REGAURDING STORM SHUTTERS FOR | | | LARGE PROJECTS. THE BUILDING OFFICIAL | | | HAS REVIEWED YOUR PROPOSAL & FOUND THAT | | | IT DOES NOT MEET THE CRITERIA OUTLINED I | | | N SECTION #14 FOR LARGE PROJECTS. | | | THERE ARE MULTIPLE SKYLIGHTS THAT | | | WILL ALSO REQUIRE PRODUCT TESTINGREPORTS | | | FOR LARGE MISSLE RESISTANCE. | | | | | | 8)- THE REFRENCE TO TYPE 1 PLYWOOD USED | | | FOR THE EXTERIOR CEILING ASSEMBLY WAS CO | | | RRECTED ON PAGE A-12, THE SAME ASSEMBLY | | | SHOWS UP ON A-14 DETAILS 12 & 13. | | | | | | 9)- THE PAGES THAT ARE VOID NEED TO BE D | | | ELETED FROM THE PLANS AND THE NEW PAGES | | | INSERTED BACK INTO THE DOCUMENT. THE | | | VOIDED PAGES ARE TO BE FOLDED PLACED ON | | | TOP OF THE PLANS (1 COPY). | | | | | | 10)-COUNTY IMPACT FEES ARE TO BE PAID BE | | | FORE THE ISSUANCE OF THE PERMIT. | | | | | | 11)_ ONE OF THE THREE SETS OF PLANS IS | | | MISSING THE STRUCTURAL DRAWINGS. THIS | | | SET OF PLANS IS WRAPPED AND NOTED. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2001-07-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-31 |
Time |
11:23 |
Rev Time |
2.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-07-31 00:00:00 | BUILDING PLAN REVIEW | | | 1801 OKEECHOBEE ROAD / 1705 BLDG#1 | | | PERMIT # 01020102 | | | TYPE IV/ PROTECTED | | | FULLY SPRINKLERED | | | OCCUPANCY: STORAGE | | | OWNER: PREMIER AIRPORT CENTER, LLP | | | | | | NOTE: THIS IS A SHELL PERNIT ONLY, THE O | | | ONLY USE OF THIS BUILDING WILL BE | | | "STORAGE", AS PER IMPACT FEES STAMP THAT | | | WILL BE ASSED. UNDER THE CITYS' PROPERTY | | | FILE THIS PROPERTY WILL HAVE RESTRICTION | | | S APPLIED FOR UNDER BUSINESS LICENSES | | | FOR STORAGE ONLY. BUSINESSES THAT DO NOT | | | REGISTER WILL PAY PENALTIES FOR NO | | | OCCUPATIONAL LICENSE PLUS BE ASSESED FOR | | | ADDITIONAL IMPACT FEES ( FOR OCCUPANCIES | | | OTHER THAN STORAGE). CITY ADMINISTRATIVE | | | CODE 104.1 A CHANGE IN OCCUPANCIES | | | REQUIRES A BUILDING PERMIT, FAILURE TO | | | SECURE A PERMIT, 4X FEE WILL BE ASSESED. | | | | | | 1)- FL STATE STATUTE 553/ CHAPTER 468 | | | PART XII CHAPTER 7 OF THE CITY CODE & | | | THE SBC REQUIRE A RESIDENT INSPECTOR ON | | | SITE AND REGISTERED WITH THE ASSISTANT | | | BUILDING OFFICIAL, DON NEELY. | | | | | | 2)- SBC 903.1 REQUIRES FIRE SPRINKLER | | | PLANS FROM THE ENGINEER,SIGNED SEALED | | | AND DATED, 3 SETS OF PLANS WILL BE | | | REQUIRED. | | | | | | 3)- ROOF DECK : PROVISO THE INFORMATION | | | FOR CLASS A OR B FOR FIRE DISTRICT & | | | PRODUCT APPROVAL FOR HIGH WIND DISTRICT. | | | PROVIDE 2 COPIES, THANK YOU. | | | | | | 4)- A SURVEY WILL BE REQUIRED,AND ELEVAT | | | ION CERTIFICATE AFTER THE SLAB IS | | | POURED.THIS BUILDING IS IN A A-9 FLOOD- | | | ZONE.THE MINIMUM ELEVATION IS 13'-6" | | | THIS IS 6" ABOVE THE BASE FLOOD BY CITY | | | CODE. | | | | | | 6)- SBC 1804.2 SOILS TEST REPORT WITH | | | THE MINIMUM BEARING VALUE. | | | | | | 7)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | BUCK ATTACHMENT FOR WINDOWS, DOORS AND | | | OVERHEAD DOORS. | | | | | | 8)- SBC 1606.4.1 AMEND. 1707.4.1 AMEND. | | | ALL GLAZED OPENINGS WILL REQUIRE PRODUCT | | | TESTING REPORTS. TEMPERED GLASS STORE- | | | FRONT SYSTEMS WILL REQUIRE PRODUCT TEST- | | | ING, THE STORM SHUTTER SYSTEM WILL RE- | | | QUIRE APPROVAL FROM THE BUILDING OFFI- | | | CIALAS IN CASES OF LARGE PROJECTS, SEE | | | CITYPOLICY FOR GLAZED OPENINGS # 14, | | | SEE ATTACHED POLICY. THIS WILL BE | | | REQUIRED BEFORE A PERMIT WILL BE ISSUED | | | THE PRODUCT APPROVALS FOR WINDOWS & DOOR | | | CAN BE A "PROVISO", GLAZED OPENINGS WILL | | | REQUIRE A SEPERATE PERMIT & FEES IF | | | PRODUCT APPROVALS ARE SUBMITTED AFTER | | | THE ISSUEANCE OF THE BUILDING PERMIT. | | | | | | 9)- STRUCTURAL STEEL SHOP DRAWING ARE | | | TO BE REVIEWED BY THE ENGINEER OF RECORD | | | BEFORE THE SUBMITTAL TO THE BUILDING | | | DEPARTMENT. | | | | | | 10)- SSHEET A-12 DETAIL #5 INDICATES A | | | 5/8" TYPE I PLYWOOD AS PART OF THE | | | EXTERIOR CEILING ASSEMBLY, TYPE IV BUILD | | | ING IN A FIRE DISTRICT, NO PLYWOOD ALLOW | | | ED. | | | | | | 11)- COUNTY IMPACT FEES PAID BEFORE THE | | | ISSUANCE OF A PERMIT. | | | | | | BUILING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 X 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2001-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-06-13 |
Time |
12:51 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-13 00:00:00 | PLAN REVIEW# 01020102 | | | 1801 OLD OKEECHOBEE / 1705 BLDG #1 | | | TYPE OF CON:TYPE IV / PROTECTED | | | FULLY SPRINKLERED | | | OCCUPANCY: STORAGE | | | OWN: PREMIER AIRPORT CENTER, LLP | | | | | | NOTE: THIS IS A SHELL PERMIT ONLY,THE | | | ONLY USE OF THIS BUILDING WILL BE | | | "STORAGE", AS PER IMPACT FEES THAT | | | WILL BE ASSED. UNDER THE CITYS' | | | PROPERTY FILE THIS PROPERTY WILL | | | HAVE RESTRICTIONS APPLIED FOR | | | BUSINESS LICENSES FOR STORAGE ONLY. | | | BUSINESSES THAT DO NOT REGISTER | | | WILL PAY PENALTIES FOR NO OCCUPA- | | | TIONAL LICENSE PLUS BE ASSESED | | | FOR ADDITIONAL IMPACT FEES. CITY | | | ADMINISTRATIVE CODE 104.1 A CHANGE | | | OF OCCUPANCY WILL REQUIRE A BUILD- | | | ING PERMIT, 4X FEE IS ASSOCIATED | | | WHEN NO PERMIT IS PULLED. | | | | | | 1)- FL STATE STATUTE 553/ CHAPTER 468, | | | PART XII, CHAPTER 7 OF THE CITY CODE & | | | THE SBC REQUIRE A RESIDENT INSPECTOR ON | | | SITE AND REGISTERED WITH THE ASSISTANT | | | BUILDING OFFICIAL. | | | | | | 2)- SBC 903.1 REQUIRE FIRE SPRINKLER | | | PLANS FROM THE ENGINEER SIGNED,SEALED & | | | DATED, 3 SETS OF PLANS WILL BE REQUIRED | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3)- SBC TABLE 600, SQ. FOOTAGE OF THE | | | BUILDING REQUIRES THE BUILDING TO BE | | | 1 HR. PROTECTED. | | | | | | 4)- FIRE ZONE SBC 102.2.4 ROOF COVERING | | | IN THE FIRE DISTRICT SHALL CONFORM TO | | | THE REQUIREMENTS OF A CLASS "A OR B" | | | ROOF. | | | | | | 5)- SURVEY REQUIRED, SBC 104.2.2. | | | | | | 6)- SBC 1804.2 SOIL TEST REPORT WITH THE | | | MINIMUM BEARING VALUE. | | | | | | 7)- SBC 1606.2.6.2 COMPONENTS & CLADDING | | | BUCK ATTACHMENT FOR ALL WINDOWS, DOORS, | | | INCLUDING OVERHEAD. | | | | | | 8)- SBC 1606.4.1 AMEND/ 1707.4.1 AMEND. | | | ALL GLAZED OPENINGS WINDOWS, DOORS, AND | | | SKYLIGHTS WILL REQUIRE PRODUCT APPROVAL | | | FOR LARGE MISSLE RESISTANCE TESTING. IF | | | THE PRODUCT HASN'T RECEIVED THIS TESTING | | | STORM SHUTTERS WILL BE REQUIRED WITH | | | PRODUCT TESTING. SEE WEST PALM BEACH | | | STORM SHUTTER POLICY FOR LARGE STRUCTURE | | | | | | 9)- ROOFING SBC 1503.1.3- INSULATION | | | FASTENING SCHEDULE, WILL REQUIRE WIND | | | LOADS WIND RESISTANCE TESTING. | | | | | | 10)- SRUCTURAL STEEL SHOP DRAWINGS ARE | | | TO BE REVIEWED BY THE ENGINEER OF RECORD | | | BEFORE SUBMITTAL OF THE BUILDING DEPART- | | | MENT. | | | | | | LOOK FOR COMMENTS BY THE OTHER PLAN | | | REVIEW DISCIPLINES THAT MAY BE WRITTEN | | | ON THE APPLICATION, PLANS OR ATTACHED | | | SEPERATELY. WHEN RE-SUBITTING PLANS | | | PLEASE CLEARLY INDICATE THE REVISION | | | AND REMOVE AND REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING | | | THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND, | | | WILL HELP TO EXPEDITE TO YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JIM WITMER | | | PLAN REVIEW | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-02-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-02-12 |
Time |
14:34 |
Rev Time |
10.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-12 00:00:00 | PERMIT # 01020102 | | | 1805 OLD OKEECHOBEE RD. (1701) | | | OCCUPANCY: WAREHOUSE | | | OWN: PREMIER AIRPORT CENTER, LLP | | | | | | 1)- THE BUILDING CODE ANALYSIS" BUILDING | | | AREA STATISTICS" IS FROM THE S.F.B.C., | | | THE CITY OF W.P.B. USES THE S.B.C., 1997 | | | EDITION. TO DO A PLAN REVIEW UNDER THE | | | STANDARD BUILDING CODE ER ARE USING THE | | | FOLLOWING CRITERIA: | | | OCCUPANCY: STORAGE | | | TYPE OF CONS: TYPE IV | | | PROTECTED: 1 HOUR | | | FULLY SPRINKLERED | | | ALLOW AREA : 72,000 SQ. FT. | | | ACTUAL AREA : 104322 SQ. FT. | | | | | | TABLE 500 ALLOW AREA 72,000 SQ. FT. | | | SBC 503.3 AREA INCREASE | | | P= 1620 F= 1460 | | | F/P= .90I=90% X 24,000= 21,600 | | | ALLOW AREA = 72,000 | | | TOTAL = 93,600 | | | ***SOLUTION*** | | | DIVIED THE BUILDING WITH A 4HR FIRE WALL | | | MAKING (2) BUILDINGS, EACH WILL CLEARLY | | | BE UNDER THE ALLOWABLE AREA. | | | 2)- FL STATE STATUTE 553/ CHAPTER 468, | | | PARTXII, CHAPTER 7 OF THE CITY CODE & | | | THE STANDARD BUILDING CODE REQUIRE A | | | RESIDENT INSPECTOR ON SITE AND REGISTER- | | | ED WITH ASSISTANT BUILDING OFFICIAL DON | | | NEELY. | | | 3)- SBC104.2.2- ADDTIONAL INFORMATION RE | | | QUIRED, THIS OCCUPANCY BEING STORAGE BY | | | DEFINITION WILL REQUIRE ADD. INFO. FOR | | | SUBCLASSIFICATIONS, SBC 312.2 | | | S-1 MODERATE HAZARD STORAGE | | | S-2 LOW HAZARD STORAGE | | | 4)- FIRE SPRINKLER PLANS TO BE ENGINEER- | | | ED, SIGNED SEALED & DATED. 2 SETS REQUIR | | | ED BEFOFRE THE ISSUANCE OF THE PERMIT. | | | SBC 903.1. | | | 5)- TABLE 600, INTERIOR COLUMNS & STEEL | | | SUPPORTING THE ROOF REQUIRE 1 HR. | | | PROTECTION, DETAILS. | | | 6)- FIRE ZONE SBC 102.2.4, ROOF COVERING | | | IN THEFIRE DISTRICT SHALL CONFORM TO | | | THE REQUIREMENTS OF A CLASS A OR B ROOF | | | COVERINGS AS DEFINED IN 1503.2. | | | 7)- SBC 704.2.2.2, THE USAGE OF THIS | | | BUILDING, IS IT A SINGLE OR MULTIPLE | | | TENANTS & OCCUPANCIES? | | | 8)- SBC 411.1 HIGH PILED COMBUSTIBLE | | | STORAGE & HIGH RACK STORAGE SYSTEMS? | | | 9)- SBC 104.2.2 ADDITIONAL INFORMATION: | | | IS THIS A SHELL PERMIT ONLY, THEREIS NO | | | RESTROOMS? | | | 10)- SURVEY REQUIRED, SBC 104.2.2. | | | 11)- SBC 1804.2 SOILS TEST REPORT WITH | | | THE MINIMUM BEARING VALUE. | | | 12)- SBC 1606.2.6.2- COMPONENTS & CLADD- | | | ING.BUCK ATTACHMENT FOR ALL WINDOWS, | | | DOORS,OVERHEAD DOORS & SKYLIGHTS. | | | 13)- SBC 1606.4.1 AMEND. / 1707.4.1 | | | AMEND. ALL GLAZED OPENINGS WINDOWS,DOORS | | | & SKYLIGHTS REQUIRE PRODUCT APPROVAL FOR | | | LARGE MISSLE RESISTANCE. IF THIS TEST | | | WASN'T PERFORMED THEN STORM SHUTTERS | | | WITH EITHER DADE COUNTY OR SBCCI TESTING | | | REPORTS ARE ACCEPTED. | | | 14)- ROOFING SBC 1503.1.3- INSULATION/ | | | FASTENING SCHEDULE, WILL REQUIRE WIND- | | | LOADS/ WIND RESISTANCE TESTING. | | | 15)- STRUCTURAL STEEL SHOP DRAWINGS ARE | | | TO BE REVIEWED BY THE ENGINEER AND | | | APPROVED BY THE ENGINEER OF RECORD BEFOR | | | SUBMITTAL TO THE BUILDING DEPARTMENT. | | | 16)- SBC F102.2.6 EXTERIOR WALLS LOCATED | | | WITHIN 30' OF PROPERTY LINE SHALL HAVE A | | | FIRE RESISTANCE OF 2 HRS. A ASSUMED | | | PROPERTY LINE WILL NEED TO BE ASSIGNED | | | BETWEEN BUILDINGS. | | | 17)- SBC TABLE 600 EXTERIOR BEARING | | | WALLS BETWEEN BUILDINGS WILL REQUIRE A | | | ASSIGNED PROPERTY LINE BETWEEN BUILDINGS | | | 40% OPENINGS ALLOWED, SEE "KNOCK OUT | | | PANELS" NOTE. | | | SBC F102.2.8 FABRIC CANOPIES TO COMPLY | | | WITH FLAME RESISTANT MATERIALS IN ACCORD | | | ANCE WITH SBC 3103.1. | | | SHEET A-12 DETAIL 7/15, THIS DETAIL IS | | | DESIGNATED FOR 3 DIFFERENT DETAILS, WHEN | | | IT CAN BE USED FOR ONLY ONE APPLICATION | | | WHICH IS ACTUALLY A ROOF EXSPANSION | | | JOINT!!! | | | | | | BUILDING STRUCTURAL REVIEW | | | JIM WITMER | | | (561) 659-8096 EX. 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2002-04-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-04-05 |
Time |
08:31 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2002-04-05 |
Time |
07:59 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-07-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-07-31 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-06-12 |
Time |
23:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-06-12 |
Time |
23:39 |
Sent To |
|
|
| Notes |
| 2001-06-13 00:00:00 | **************** UNSAT ************** | | | | | | 1)NOTE: PLEASE NOTE THAT COMMENT FROM | | | FIRST REVIEW WAS NOT ADDRESSED. | | | | | | PLEASE PLACE NOTE ON ELECTRICAL ROOM | | | LAYOUT DIAGRAM ON E0.1. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-02-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-26 |
Time |
08:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-26 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2001-02-26 00:00:00 | ******************* UNSAT ************** | | | | | | 1)NOTE: PLEASE PROVIDE NOTE AND | | | CLARIFICATION ON PLAN FOR THE REQ`MENTS | | | OF 110-26. | | | FUTURE FIBER OPTIC RACK BEING SHOWN IN | | | THE CLEARENCE AREA FOR ELECTRCIAL | | | EQUIPMENT. | | | PLEASE PROVIDE NOTE ONPLAN. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANYQUESTIONS | | | PLEASE CALL. | | | | | | DEWEYPALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2002-03-11 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2002-03-11 |
Time |
09:08 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2002-03-11 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2002-03-11 00:00:00 | PASSED: | | | 1. REVISION TO RELOCATE THE FIRE HYDRANT | | | AS SUBMITTED APPROVED. | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2001-07-06 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-07-06 |
Time |
08:52 |
Rev Time |
5.00 |
| Received By |
mamini |
Date |
2001-07-06 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2001-07-06 00:00:00 | PASSED: | | | 1. RESPONSES TO THE PREVIOUS REVIEW | | | COMMENTS DATED 6-5-01 SATISFACTORY. | | | PLANS HAVE BEEN REVISED PER REVIEW | | | COMMENTS. | | | | | | IF ANY QUESTIONS PLEASE CONTACT 659-8096 | | | EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2001-06-05 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-06-05 |
Time |
11:32 |
Rev Time |
4.00 |
| Received By |
mamini |
Date |
2001-06-05 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2001-06-05 00:00:00 | FAILED: | | | 1. PLEASE PROVIDE POLLUTION PREVENTION | | | PLAN. POLLUTION PREVENTION PLAN MUST BE | | | INSTALLED IN THE FIELD PRIOR TO ANY | | | EARTH WORKS. | | | 2. PLEASE PROVIDE STORM WATER | | | CALCULATION FOR OUR REVIEW IF YOU HAVE | | | NOT SUBMITTED TO JOSE DEL RIO, STORM | | | WATER ENGINEER AT 1000 45TH STREET WPB, | | | FL 33407.SEE ATTACHED | | | 3. PLEASE PROVIDE PERVIOUS & IMPERVIOUS | | | CALCULATIONFOR THE SITE, SIGNED AND | | | SEALED BY THE DESIGN ENGINEER.THE | | | TOTAL AMOUNT MUST BE EQUAL TO 100% OF | | | TOTAL SITE ACRES OR S.F. | | | 4. PROVIDE H.C RAMPS FOR 5' WALK AT ALL | | | ENTRANCES ALONG OLD OKEECHOBEE ROAD. | | | CROSS WALKS SHOULD BE WHERE PEDESTRIANS | | | CROSS. | | | 5. A SEPARATE PERMIT THROUGH CITY | | | ENGINEERS OFFICE FOR ALL THE WORKS | | | WITHIN PUBLIC R.O.W IS REQUIRED. | | | 6. A SEPARATE PERMIT THROUGH PUBLIC | | | UTYLITIES ENGINEERING SERVICES | | | DEPARTMENT FOR ALL THE CROSS CONNECTIONS | | | IS REQUIRED. | | | 7. DUMPSTER ENCLOSURES MUST HAVE A MIN. | | | OF 12'-6" OPENING BETWEEN THE GATE POSTS | | | PER CITY STANDARD. | | | IF ANY QUESTION PLEASE CONTACT 561-659- | | | 8096 EXT. 8492 MOHAMMAD R. AMINI |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2001-02-28 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-02-28 |
Time |
14:22 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2001-02-28 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2001-02-28 00:00:00 | FAILED: | | | 1. NOT ADEQUATE INFORMATION PROVIDED FOR | | | ENGINEERING REVIEW.PLEASE RESUBMIT | | | WHEN CIVIL DRAWINGS ARE DEVELOPED. | | | IF ANY QUESTION CONTACT 569 8096 | | | EXT. 8492 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2002-04-05 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-11-14 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-07-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-07-05 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-07-05 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-06-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-06-06 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-06-06 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2001-06-06 00:00:00 | 1) PREVIOUS PLAN REVIEW COMMENTS NOT | | | ADDRESSED. | | | 2) NO FIRE SPRINKLER DRAWINGS OR | | | HYDRAULIC CALCULATIONS PROVIDED WITH | | | PLANS. | | | 3) FIRE ALARM NOTES SECTION INDICATES | | | CLASS B, STYLE C FIRE ALARM CIRCUITS. | | | ONLY CLASS A, STYLE D CIRCUITS OR | | | FULLY ADDRESSABLE FIRE ALARM SYSTEM WILL | | | BE ALLOWED. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2001-02-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-02-06 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-02-06 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2001-02-06 00:00:00 | 1) WHAT PRODUCTS WILL BE STORED IN THE | | | WAREHOUSE. WILL IT BE LIGHT HAZARD, | | | ORDINARY OR HIGH HAZARD. ARE ANY RACKS | | | PLANNED TO BE USED. | | | 2) PLEASE INDICATE ALL EXISTING FIRE | | | HYDRANTS, EXISTING FIRE MAINS, NEW FIRE | | | HYDRANTS AND NEW WATER MAINS. | | | 3) A FIRE LANE MAY BE REQUIRED FOR | | | BUILDING 1 BECAUSE OF ITS HEIGHT AND | | | SETBACK FROM THE ROAD. | | | 4) A KNOX-BOX WILL BE REQUIRED. | | | 5) BUILDING ADDRESS NOT SHOWN ON | | | ELEVATION DRAWINGS. BUILDING ADDRESS TO | | | COMPLY WITH CITY CODE REQUIREMENTS. | | | 6) PLEASE PROVIDE COMPLETE FIRE ALARM | | | SYSTEM SHOP DRAWINGS AND A PERMIT PRIOR | | | TO INSTALLATION. CUT SHEETS, WIRING | | | DIAGRAM AND BATTERY CALCULATIONS WILL | | | BE REQUIRED. THE FIRE SPRINKLER AND | | | FIRE ALARM SYSTEM ARE TO BE SUPERVISED | | | BY A LICENSED UL LISTED CENTRAL STATION | | | APPROVED BY THE FIRE RESCUE DEPARTMENT. | | | THE FIRE ALARM SYSTEM TO BE CLASS A OR | | | FULLY ADDRESSABLE. | | | 7) NO FIRE SPRINKLER DRAWINGS PROVIDED | | | WITH PLANS. COMPLETE FIRE SPRINKLER | | | PLANS AND HYDRAULIC CALCULATIONS ARE TO | | | BE SUBMITTED WITH THESE DRAWINGS BEFORE | | | A BUILDING PERMIT WILL BE ISSUED. | | | 8) PROVIDE MORE DETAILS ON THE FIRE | | | PUMP ASSEMBLY PLANNED FOR THE BUILDING. | | | 9) FIRE ALARM NOTES INDICATES CLASS B, | | | STYLE C CIRCUITS. ONLY CLASS A, STYLE D | | | WILL BE PERMITTED. | | | 10) ANY CANVAS AWNINGS ARE TO BE FIRE | | | RETARDANT. | | | 11) ALL STAIRS TO COMPLY WITH NEW STAIRS | | | NFPA 101, THE LIFE SAFETY CODE, 1985 | | | EDITION. | | | 12) IS BUILDING 1 BE A SINGLE TENANT | | | OR MULTIPLE TENANT. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2002-02-28 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2002-02-28 |
Time |
15:30 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2002-02-28 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2002-02-28 00:00:00 | MECHANICAL PERMIT 01051485 - SUBMITTAL | | | FOR SHELL - ROOF CURBS, EXHAUST FANS & | | | LOUVERS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-07-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-07-06 |
Time |
15:45 |
Rev Time |
0.45 |
| Received By |
pkrauss |
Date |
2001-07-06 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2001-07-06 00:00:00 | THIS IS FOR SHELL ONLY MECHCANICAL | | | PERMIT #01051485. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2001-06-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-06-09 |
Time |
12:11 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-06-09 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2001-06-09 00:00:00 | ********************DENIED************** | | | | | | | | | PLEASE PROVIDE THE FOLLOWING INFORMATION | | | | | | | | | IS THIS PERMIT FOR SHELL ONLY? | | | | | | WHAT IS BEING STORED IN THE WARHOUSE, | | | I.E. COMBUSTIBLES? | | | | | | EXHAUST FANS IN METER/PUMP ROOMS SHALL | | | COMPLY WITH 1997 SMC 506.1, 10' MINIMUM | | | FROM ANY ADJACENT BUILDING, WINDOW, DOOR | | | OR AIR INTAKE AND 10' ABOVE THE | | | ADJOINING GRADE LEVEL. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE | | | CONTACT PATTY KRAUSS AT 659-8096 EXT | | | 8388. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2001-02-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-02-23 |
Time |
12:34 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-02-23 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2001-02-23 00:00:00 | ****************DENIED****************** | | | | | | INSUFFICIENT INFORMATION FOR MECHANICAL | | | REVIEW.SUBMIT PLANS WITH MECHANICAL | | | PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2002-07-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2002-07-13 |
Time |
12:22 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2002-07-13 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2002-07-13 00:00:00 | SUBMITTALS FOR THE IRRIGATION SYSTEM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2002-04-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2002-04-10 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2002-04-10 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2002-04-10 00:00:00 | SUBMITTAL APPROVAL - FLOOR DRAINS, CLEAN | | | OUTS, ROOF DRAINS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2001-11-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-26 |
Time |
09:57 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-11-26 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2001-09-12 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-09-12 |
Time |
15:02 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-09-12 00:00:00 | PLUMBING PLAN REVIEW,PROVISO | | | WATER HAMMER ARRESTORS DELETED ON HOSE | | | BIBBS,PES |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2001-08-31 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-08-31 |
Time |
15:31 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-08-31 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2001-08-31 00:00:00 | DENIED... | | | | | | REFERENCE SPC-94 | | | | | | 1) PAGE PD-4 PREVIOUS COMMENTS FROM 7-17 | | | PIPE NOT SIZED AS REQUESTED FOR UNDER | | | GROUND PIPING FROM BUILDING RAIN LEADERS | | | TO STORM CATCH BASIN. ALSO PAGE PD-3 | | | | | | 2) PAGE P0-1, WATER RISER DIAGRAM, WATER | | | HAMMER ARRESTORS SHALL BE INSTALLED PER | | | MANUFACTURE'S INSTALLATION INSTRUCTIONS | | | AND WH-PDI 201. (SEE ATTACHED SHEET) | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2001-07-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-07-17 |
Time |
16:09 |
Rev Time |
3.00 |
| Received By |
jleech |
Date |
2001-07-17 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2001-07-17 00:00:00 | DENIED; | | | | | | 1.PAGE PO.1 (PLUMBING NOTES) NOTE #11 | | | CALLS FOR CAST IRON PIPE ABOVE GROUND. | | | PAGE A-15 (OVERFLOW SCUPPER DETAIL) | | | HAS A NOT THAT CALLS FOR PVC PIPE. | | | CHANGE NOTE NOTE 11 OR OVERFLOW | | | SCUPPER DETAIL. | | | | | | 2.TOTAL RAIN CAULKULATIONS IS 119725 SQ. | | | FEET.PLEASE CHECK AND SHOW CAULKS ON | | | PLANS I AM NOT AN ENGINEER. THIS IS | | | THIRD REQUEST FOR THIS INFORMATION. | | | 3.PAGE A-5 DOWN SPOUTS FROM PUMP ROOM | | | AND ELECTRICAL ROOF AREA SHALL GO TO | | | STORM DRAINAGE PER 94 SPC SEC. 1101.2. | | | | | | 4.PAGE PD-4 ROOF DRAIN PIPING UNDER | | | GROUND NOT SHOWN. SHOW AND SIZE | | | PIPING FROM BUILDING RAIN LEADERS TO | | | STORM CATCH BASIN. | | | | | | 5.AIR HAMMER ARREESTERS SHALL BE | | | INSTALLED PER MANUFACTORS | | | SPECIFICATIONS. SHOULD BE NEAR FIXTURE | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT 8369 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-06-09 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-06-09 |
Time |
09:40 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-06-09 00:00:00 | PLUMBING PLAN REVIEW"DENIED 2ND X" | | | (1) COMMENTS DATED 02-27-01 HAVE NOT | | | BEEN ADDRESSED. | | | (2) SHTA5,A6,PROVIDE CALCULATIONS FOR | | | SIZING INDIVIDUAL ROOF DRAINS,SPC 94 TAB | | | 1108.1.2, USING FIG 1108.4 RATE OF RAIN | | | FALL, FOR WPB AREA. | | | SECONDARY ROOF DRAINS (SCUPPERS),SHOW | | | CALCULATIONS FOR INDIVIDUAL DRAINS. | | | SPC 94 SEC 1109.1 & FIG 1109.3 RATE OF | | | RAIN FALL,FOR WPB AREA. | | | (3) SHTA 11, METER & PUMP RM ROOFS, | | | PRIMARY & SECONDARY DRAINS NOT SHOWN. | | | (4) SHT P2.1, KEY NOTES,REFERENCES CIVIL | | | DRWGS FOR CONTINUATION OF STORM DRAINS, | | | PLEASE INDICATE WHICH SHTTHIS IS ON. | | | (5) SHT P2.1 & P2.2, SPC 94 SEC 407.1.1 | | | MINIMUM FACILITIES,NUMBER OF EA TYPE OF | | | FIXTURE SHALL BE INSTALLED,USE TAB 407. | | | (6) SHT P0.1 PLBG NOTES 13,18,REFERENCE | | | AIR CHAMBERS,SHOW A DETAIL OF APPROVED | | | AIR CHAMBER AND HOW IT WILL BE RECHARGE- | | | ABLE,ACCESSIBLE SPC 94 SEC 607.8.3 | | | (7) SHTS PP1 TO 4,PROVIDE INFORMATION ON | | | IRRIGATION SYSTEM, SPC 94 SEC 104.3 | | | LOCATION AND TYPE OF BACK FLOW PREVENTER | | | END OF COMMENTS PAUL SCHMITZ | | | QUESTIONS561-659 8096- X8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-02-27 |
Time |
11:08 |
Rev Time |
2.50 |
| Received By |
pschmitz |
Date |
2001-02-27 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2001-02-27 00:00:00 | DENIED; | | | | | | 1.ROOF DRAINS; SHOW SQ. FT. AREA THAT | | | EACH ROOF DRAIN WILL DRAIN USING 94 | | | SPC CHAPTER 11 AND CHART 1108.4. RAIN | | | FALL IS 4.5 IN. PER. HR.IN THIS AREA, | | | AND 1/2 OF THE TOTAL AREA OF THE | | | PARAPET WALL MUST BE USED TO CALCULATE | | | THE SIZE OF ROOF DRAINS. SHOW CALKS. | | | | | | 2.WHERE DOES RAIN WATER FROM ROOF GO | | | AFTER IT LEAVES THE BUILDING? NO STORM | | | SEWER, SANITARY SEWER, OR WATER | | | SERVICE IS SHOWN ON SITE PLANS. | | | | | | 3.AREA WHERE PLUMBING MIGHT BE INSTALLED | | | SHOULD HAVE 6 X 4 YEE'S INSTALLED IN | | | THE BUILDING DRAIN AT TIME OF INSTALL- | | | ATION. THIS INSURES THE INTEGRITY OF | | | THE BUILDING DRAIN. | | | | | | 4.ONE 3" VENT SHALL BE INSTALLED THRU | | | ROOF 94 SPC SEC.904.3.1. | | | | | | 5.WATER MAIN SHOULD HAVE FUTURE DROPS | | | WITH SHUTOFF VALVES WHERE PLUMBING MAY | | | BE INSTALLED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2001-09-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-09-18 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-09-18 00:00:00 | ZONING PASSED PER S.GRAHAM SEE APP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-06-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-06-05 |
Time |
10:18 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|