| Plan Review Stops For Permit 01011146 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-01-30 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-01-30 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-01 |
Time |
19:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-01 |
Time |
19:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-01 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-01 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2001-02-01 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT LOAD CALCUALTIONS | | | FOR SERVICE.215-5 | | | | | | 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRNET PER 110-9. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IFTHERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 | | | | | | | | | 3) NOTE: PLEASE SHOW ALL CONTINUOUS AT | | | 125%. (LIGHTING ETC) |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2001-03-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-03-13 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-02-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-02-08 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-02-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2001-02-08 00:00:00 | 1) DOOR LEADING INTO WAITING ROOM 001 | | | TO BE AT 45 MINUTE FIRE RATED. | | | CLOSING DEVICES REQUIRED ON ALL RATED | | | FIRE DOORS. | | | | | | APPROVED PROVISO: | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2001-06-07 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-06-07 |
Time |
09:36 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-06-07 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2001-06-07 00:00:00 | ********************DENIED************** | | | | | | | | | DID RATING OF WALL CHANGE...IF SO, WAS | | | IT SUBMITTED TO BUILDING PLAN REVIEW. | | | | | | DAMPER MAY NOT BE REMOVED UNLESS IT | | | MEETS THE REQUIREMENTS OF 1997 SMC | | | 610.1.3 ITEM 3. | | | | | | 1.DUCT SHALL NOT EXCEED 100 SQ INCHS. | | | 2.SHALL BE OF 0.0217" MIN. STEEL. | | | 3.DUCT SHALL CONTINUE W/NO OPENINGS | | | FOR 5' FROM THE RATED WALL & | | | 4.DUCT SHALL BE INSTALLED ABOVE | | | CEILING. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-03-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-03-09 |
Time |
13:36 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2001-03-09 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2001-03-09 00:00:00 | PROVISO:AS PER NANCY'S REVIEW 2/6/01 | | | | | | ALL FOUR SECTIONS OF 1997 610.1.3 (3) | | | INCLUDING 100 SQ. IN., ABOVE CEILING, | | | MINIMUM 26 GA. AND EXTEND FOR 5 FT. ON | | | EACH SIDE OF THE RATED WALL BEFORE ANY | | | OPENINGS IN THE DUCT. | | | | | | APPROVED AS PER NCD 2/6/01. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2001-02-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-02-06 |
Time |
14:48 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-02-06 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2001-02-06 00:00:00 | PROVISO: | | | ALL FOUR SECTIONS OF 1997 SMC 610.1.3 | | | (3) INCLUDING MAXIMUM 100SQ. IN., ABOVE | | | CEILING, MIN. 26 GA. AND EXTEND FOR 5 | | | FT. ON EACH SIDE OF THE RATED WALL | | | BEFORE ANY OPENINGS IN THE DUCT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-10 |
Time |
06:23 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2001-03-10 |
Time |
06:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2001-02-04 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-02-04 |
Time |
07:46 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-02-04 00:00:00 | PLUMBING PLAN REVIEWDENIED | | | (1) SHT A-1 | | | PLUMBING PLAN REVIEWDENIED | | | CODE REFERENCES SPC 94,FACBC 97 | | | (1A) SHT.A-1 BREAK RM.#010 SEC.4.13.6 | | | MANEUVERING CLEARANCE AT DOORS. | | | SEC. 4.24.5 DOOR SWING INTO CLEAR FLOOR | | | SPACE OF SINK, | | | (B) BREAK RM. SINK SEC. 4.24 MAX HIGTH | | | 34" FF, CLEAR FLR SPACE 30"X48" KNEE | | | CLEARANCE 19". | | | (2A) SHT M-1 SEC.303,LIST MATERIALS, | | | SPECIFICATIONS. | | | (B) WATER PIPE RISER,AIR CHAMBERS TO BE | | | READLY ACCESSIBLE,RECHARGEABLE, | | | SEC 607.8.3 | | | (C) SANITARY RISER SEC 908.1 EACH | | | FIXTURE TRAP SHALL HAVE A PROTECTING | | | VENT. W/C & F/D, RM 005. | | | (D) WATER HEATERS ABOVE CEILING,SHALL BE | | | READLY ACCESSIBLE SEC 501.7, SHOW A | | | DETAIL OF A WORKING PLATFORM WITH A | | | FIXED SHIPS LADDER IN PLACE. | | | END OF COMMENTS,CONTACT PAUL SCHMITZ | | | 561-659-8096 X 8233 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2001-03-13 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2001-03-13 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|