Plan Review Details - Permit 01011132
Plan Review Stops For Permit 01011132
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-01-30 Cont ID  
Sent By dpalmer Date 2001-01-30 Time 20:46 Rev Time 0.00
Received By dpalmer Date 2001-01-30 Time 20:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-02-13 Cont ID  
Sent By pkrauss Date 2001-02-13 Time 14:29 Rev Time 0.33
Received By pkrauss Date 2001-02-13 Time 14:29 Sent To  
Notes
2001-02-13 00:00:00PROVISO:NO CONDESATE LINE SHOWN ON
 PLAN, RUN IS ACCORDANCE WITH 1997 SMC
 304.8.4 AND 304.8.6.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2001-01-29 Cont ID  
Sent By jleech Date 2001-01-29 Time 07:43 Rev Time 0.33
Received By jleech Date 2001-01-29 Time 07:42 Sent To  
Notes
2001-01-29 00:00:00DENIED;
  
 1.SHT. A-2 SHOULD SHOW A/H LOCATION. A/C
 DRAWING SHOWS A/H IN LINEN CLOSET.
  
 2.SHOW RETURN AIR LOCATION AND SIZE.
  
 3.WHAT SIZE IS DUCT FROM A/H HEADING
 TOWARD THE FRONT DOOR.
  
 A/C PLAN REVIEW BY
 JOHN LEECH
 659-8096 EXT.8377

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-01-29 Cont ID  
Sent By jleech Date 2001-01-29 Time 08:08 Rev Time 0.25
Received By jleech Date 2001-01-29 Time 08:08 Sent To  
Notes
2001-01-29 00:00:00PROVISO;SHOWER STALL TO BE 30" WIDE
 AND 1032 SQ. IN.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-02-13 Cont ID  
Sent By fknapp Date 2001-02-13 Time 13:36 Rev Time 4.00
Received By fknapp Date 2001-02-13 Time 13:36 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2001-02-05 Cont ID  
Sent By fknapp Date 2001-02-05 Time 14:14 Rev Time 4.00
Received By fknapp Date 2001-02-05 Time 14:14 Sent To  
Notes
2001-02-05 00:00:00 
 *************BUILDING UNSAT*************
  
 SBC 104.2.2
  
 1) PROVIDE ENERGY CALCULATIONS THAT HAVE
 SIGNATURE OF OWNER/AGENT THAT ARE 1997
 FORMS INCLUDING MANUEL J.
  
 2) PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH
 SPECIFIC ANCHORS AND MOUNTING TO BE USED
 FOR ALL NON-IMPACT GLAZING.
  
 3) PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR STEEL ENTRY DOORS COMPLETE WITH
 APPROVED DRAWINGS.
  
 4) PROVIDE NORANDEX PRODUCT APPROVALS
 WITH RAISE SEAL AND ORIGINAL SIGNATURE
 OF DESIGNER OF RECORD WITH JOB/SITE
 LOCATION.
  
 5) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 6) PROVIDE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE.
  
 7) PROVIDE SLEEPING ROOM WINDOWS THAT
 COMPLY EMERGENCY EGRESS REQUIREMENTS
 1997 SBC 1005.4
  
 8) PROVIDE DESIGN DATA ON SHEET A-1
 THAT REFERENCES CURRENT 1997 SBC
  
 NOTE: DRIVE PERMIT WILL BE REQUIRED.
  
 ANY QUESTIONS PLEASE CALL,
 FRANK KNAPP
 BUILDING PLAN REVIEW
 DEPARTMENT OF CONSTRUCTION SERVICES
 CITY OF WEST PALM BEACH
 (561) 659-8096 EXT. 8392

Review Stop Z ZONING
Rev No 1 Status P Date 2001-02-06 Cont ID  
Sent By fknapp Date 2001-02-06 Time 09:13 Rev Time 0.25
Received By fknapp Date   Time   Sent To  
Notes
2001-02-06 00:00:00OK PER S.GRAHAM