Plan Review Details - Permit 01011120
| Plan Review Stops For Permit 01011120 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-03-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-08 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-08 |
Time |
17:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-02-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-28 |
Time |
19:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-28 |
Time |
19:15 |
Sent To |
|
|
| Notes |
| 2001-02-28 00:00:00 | **************** UNSAT *************** | | | | | | 1)NOTE: PLEASE NOTE WHEN PLANS WERE | | | FIRST SUBMITTED NO ELECTRICAL SERVICE | | | CHANGE WAS SUBMITTED. PLEASE NOTE, NOW | | | THERE IS MORE INFORMATION THAT IS | | | NEEDED. | | | NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2)NOTE: PLEASE SEE LOAD CALCULATION | | | SUBMITTED. PLEASE NOTE TWO(2) SM APPL | | | CIRCUITS ARE REQ`D. | | | | | | 3)NOTE: PLEASE CLARIFY THE EQUIPMENT | | | GROUNDING CONDUCTOR BETWEEN MAIN AND | | | PANEL. PER 250-122 | | | | | | 4) NOTE: PLEASE SHOW GROUNDING | | | ELECTRODEGOING TO BUILDING STEEL OF NEW | | | BLDG TO BE BONDED. PER 250-50. | | | | | | 5)NOTE: PLEASE NOTE THAT ALL ITEMS THAT | | | WERE REDLINED ON FIRST REVIEW NEED TO BE | | | DRAWN IN IN THE MANNER IN WHICH THE REST | | | OF THE PLANS ARE DRAWN.104.2 ADMIN | | | CODE. | | | | | | PLEASE SHOW LOCATION OF NEW EQUIPMENT IF | | | KNOWN AT THIS TIME. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2001-01-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-29 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-29 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2001-01-29 00:00:00 | ****************** UNSAT *************** | | | | | | | | | | | | | | | 1) NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | ALSO ON EACH LEVEL OF A MULTI-LEVEL | | | DWELLING UNIT. ROOMS WITH BATHS AND OR | | | CLOSETS ARE CONSIDERED SLEEPING ROOMS. | | | PER NFPA-72 2-2.1.1.1. | | | | | | 2) PLEASE NOTE EITHER MISSING EGRESS | | | LIGHTING AND/OR CLARIFY EGRESS LIGHTING | | | PER 210-70 OF THE NEC. DO THE FANS IN | | | GUEST SUITE AND DEN HAVE LT KITS? | | | | | | 3) NOTE: PLEASE SHOW ALL OUTLET SPACING | | | TO MEET 2`,6`,12` RULE PER 210-52. | | | | | | 4)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | AND SHOW SIZE OF EXISITNG ELECTRCIAL | | | SERVICE. 215-5 AND 220-3-C-1. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-02-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-02-24 |
Time |
11:22 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-02-24 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2001-02-24 00:00:00 | PROVISO; | | | | | | 1.SHOW R/A LOCATION. (SHOULD BE IN | | | CENTER ROOM.) ALSO SHOW SIZE OF RETURN | | | | | | 2.SHOW DUCT SIZE TO DROP IN ROOM THAT | | | A/H IS IN. | | | | | | 3.SHOW LOCATION OF C.U. C.U. SHOULD BE | | | ON A SOLID CONCRETE SLAB MINIMUM OF 3" | | | | | | | | | REVISED DRAWINGS REQUIRED BEFORE ROUGH | | | A/C INSPECTION. | | | | | | A/C PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2001-01-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-27 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2001-01-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-27 |
Time |
07:06 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2001-03-09 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2001-03-09 |
Time |
10:03 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2001-03-09 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2001-02-08 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2001-02-08 |
Time |
10:32 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2001-02-08 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2001-02-08 00:00:00 | | | | | | | *************BUILDING UNSAT************* | | | | | | SBC 104.2.2 | | | | | | 1) PROVIDE ENERGY CALCULATIONS THAT HAVE | | | SIGNATURE OF OWNER/AGENT. | | | | | | 2) PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING. | | | | | | 3) PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR ROOF COVERING UNDER SEPARATE PERMIT. | | | | | | 4) PROVIDE VENTILATION FOR FLAT ROOF PER | | | 1997 SBC 2309.7.2 | | | | | | 5) PROVIDE MECHANICAL DRAWINGS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | 6) BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO.,THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. | | | | | | ANY QUESTIONS PLEASE CALL, | | | FRANK KNAPP | | | BUILDING PLAN REVIEW | | | DEPARTMENT OF CONSTRUCTION SERVICES | | | CITY OF WEST PALM BEACH | | | (561) 659-8096 EXT. 8392 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2001-02-08 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2001-02-08 |
Time |
12:44 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|