| 2001-01-08 00:00:00 | BUILDING PLAN REVIEW |
| | 1)- FL. ACCESSIBILITY CODE-4.13.5 DOORS |
| | CLEAR WIDTH: DOORWAYS SHALL HAVE A MIN- |
| | IMUM CLEAR OPENING OF 32" WITH THE DOOR |
| | OPEN 90 DEGREES, MEASURED BETWEEN THE |
| | FACE OF THE DOOR AND THE OPPOSITE STOP. |
| | THE RESTROOM DOORS NEED TO BE REPLACED |
| | SINCE THEY DO NOT CONFORM WITH THE |
| | ACCESSIBILITY CODE. |
| | THE FLORIDA ACCESSIBILITY CODE 4.1.6.2.2 |
| | ALTERATIONS TO AN AREA CONTAINING A |
| | PRIMARY FUNCTION.ALTERATIONS MADE TO |
| | PROVIDE AN ACCESSIBLE PATH TO AN ALTERED |
| | AREAS SHALL BE DEEMED DISPROPORTINATE TO |
| | THE OVERALL ALTERATION WHEN THE COST |
| | EXCEEDS 20% OF THE ALTERTIONTO THE PRI- |
| | MARY FUNCTION AREA. |
| | 20% OR $2400.00 WILL HAVE TO GO INTO UP- |
| | GRADING THE BUILDING TO MEET THE CURRENT |
| | ACCESSIBILITY CODE. |
| | THERE IS ORDER IN CHOOSING WHICH SCCESS- |
| | IBLE ELEMENTS TO PROVIDE, PRIORITY |
| | SHOULD BE GIVEN TO THOSE ELEMENTS THAT |
| | WILL PROVIDE THE GREASTEST ACCESS, IN |
| | THE FOLLOWING ORDER: |
| | 1 AN ACCESSIBLE ENTRANCE- OK. |
| | 2AN ACCESSIBLE ROUTE TO THE ALTERED |
| | AREA-OK. |
| | 3 AT LEAST ONE ACCESSIBLE RESTROOM FOR |
| | EACH SEX OR A SINGGLE UNISEX RESTROOM. |
| | |
| | THIS IS WHERE THE BUILDING NEEDS TO BE |
| | UPDATED.IF THE 20% HASN'T BEEN REACHED |
| | THE NEXT ITEM IS: |
| | 4 ACCESSIBLE TELEPHONES. |
| | 5 ACCESSIBLE DRINKING FOUNTAINAND |
| | 6 ADDITIONAL ACCESSIBLE ELEMENTS SUCH AS |
| | PARKING, STORAGE & ALARMS. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | (561) 659-8096 EX 8412. |