| 2001-01-10 00:00:00 | DENIED |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 3) IN ADDITION TO SIGNING, SEALING AND |
| | DATING EACH PAGE OF THE PLANS, THE |
| | ENGINEER IN RESPONSIBLE CHARGE MUST |
| | LEGIBLY INDICATE IN A TITLE BLOCK THEIR |
| | NAME, ADDRESS AND LICENSE NUMBER ON |
| | EACHPLAN SHEET. 61G15-23.002 F.A.C. |
| | |
| | 4)PROVIDE (2) CURRENT COPIES OF SBCCI |
| | OR METRO-DADE PRODUCT APPROVALS FOR THE |
| | FOLLOWING: |
| | - SINGLE HUNG WINDOWS |
| | - SLIDING GLASS DOORS |
| | - OUTSWING METAL DOOR W/MIAMI SLIDE |
| | - STORM PANELS |
| | THE ITEMS SUBMITTED ARE NOT ACCEPTABLE. |
| | |
| | 5) PROVIDE PRODUCT APPROVAL,KEY PLAN |
| | ANDINSTALLATION SCHEDULE FOR STORM |
| | PANELS. PLEASE INDICATE THE SPECIFIC |
| | TYPE OF |
| | ANCHORS THAT WILL BE USED. |
| | |
| | 6) TRUSS LAYOUT AND TRUSS DRAWINGS ARE |
| | REQUIRED TO BE REVIEWED AND APPROVED BY |
| | THE ENGINEER OF RECORD. |
| | UPLIFTS INDICATED ON TRUSS DRAWINGS |
| | EXCEED THE VALUES SHOWN ON PLANS FOR |
| | TRUSSES: T1,T2,T4,T5,T^,T7,T9,TG10. |
| | PLEASE HAVE ENGINEER REVIEW. |
| | |
| | 7)TRUSS DRAWINGS REFERENCE ASCE 7-93. |
| | THIS IS NOT AN ACCEPTABLE DESIGN |
| | CRITERIA FOR WEST PALM BEACH. THE |
| | ADOPTED DESIGN CRITERIA IS SEC.1606 OF |
| | THE 97 STANDARD BUILDING CODE OR ASCE |
| | 7-95.PLEASE HAVE TRUSS ENGINEER CORRECT. |
| | |
| | IF YOU HAVE ANY QUESTIONS,PLEASE CALL |
| | ROBERT MCDOUGAL AT (561) 659-8096 |