Plan Review Details - Permit 00120903
Plan Review Stops For Permit 00120903
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-02-12 Cont ID  
Sent By jwitmer Date 2001-02-12 Time 18:19 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-02-12 00:00:00PROVISO: THAT THE CONTRACTOR BRING IN
 WINDOW DETAILS ON EMERGENCY EGRESS
 WINDOWS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-01-05 Cont ID  
Sent By jwitmer Date 2001-01-05 Time 11:58 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-01-08 00:00:00SEE FIRE REVIEW NOTES JW

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2001-01-08 Cont ID  
Sent By dpalmer Date 2001-01-08 Time 11:54 Rev Time 0.00
Received By dpalmer Date 2001-01-08 Time 11:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-02-09 Cont ID  
Sent By mcarsill Date 2001-02-09 Time 16:01 Rev Time 0.00
Received By mcarsill Date 2001-02-09 Time 16:01 Sent To  
Notes
2001-02-09 00:00:001) THE FIRST FLOOR EXISTING LEASE SPACE
 FOR CHARTER SCHOOL GRADES K-1 (40
 STUDENTS) MUST EITHER HAVE A DOOR
 LEADING DIRECTLY TO THE EXTERIOR OF THE
 BUILDING OR A WINDOW FOR VENTILATION AND
 RESCUE.
 2) COPIES OF THE APPLICABLE CODE SECTION
 REGARDING VENTILATION AND RESCUE WINDOWS
 HAVE BEEN ATTACHED TO THE PLANS. THESE
 WINDOWS MUST BE NO HIGHER THAN 44
 INCHES ABOVE THE FLOOR.
 3) THE EXISTING JANITOR CLOSET TO BE
 PROTECTED BY A FIRE SPRINKLER SYSTEM
 USING THE DOMESTIC WATER SYSTEM.
 4) PROVISIONS ARE TO BE MADE FOR
 HANDICAPPED CHILDREN.
 5) PLEASE PROVIDE MORE DETAILS ON
 DEMOUNTABLE PARTITIONS. PLEASE PROVIDE
 PRODUCT APPROVALS.
  
 APPROVED PROVISO:
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-12-21 Cont ID  
Sent By mcarsill Date 2000-12-21 Time 13:41 Rev Time 0.00
Received By mcarsill Date 2000-12-21 Time 13:41 Sent To  
Notes
2001-01-08 00:00:001) PLEASE INDICATE ON THE PLANS, THE
 NUMBER OF CHILDREN PLANNED FOR THE
 LOCATION, THE AGES OF THE CHIDLREN, THE
 NUMBER OF TEACHERS, AND THE AMOUNT OF
 TIME THE SCHOOL WILL BE OPEN FOR
 BUSINESS.
 2) PLEASE INDICATE IF THE BUILDING IS
 OR WILL BE FIRE SPRINKLER PROTECTED.
 3) PLEASE INDICATE INTERIOR FINISH
 INFORMATION ON THE PLANS.
 4) PLEASE BE ADVISED THAT "ROOMS
 NORMALLY OCCUPIED BY PRE-SCHOOL,
 KINDEGARTEN, OR FIRST GRADE PUPILS SHALL
 NOT BE LOCATED ABOVE OR BELOW THE LEVEL
 OF EXIT DISCHARGE. ROOMS NORMALLY
 OCCUPIED BY SECOND GRADE PUPILS SHALL
 NOT BE LOCATED MORE THAN ONE-STORY
 ABOVE THE LEVEL OF EXIT DISCHARGE".
 RE: NFPA 101, SECTION 10-1.1.1.
 5) EMERGENCY ESCAPE WINDOWS NOT SHOWN
 ON PLANS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-02-13 Cont ID  
Sent By ndenmark Date 2001-02-13 Time 09:56 Rev Time 1.00
Received By ndenmark Date 2001-02-13 Time 09:56 Sent To  
Notes
2001-02-13 00:00:00PROVISO
 THIS PERMIT WILL REQUIRE A FIELD
 INSPECTION TO ASSURE CODE COMPLIANCE
 FOR EXISTING EQUIPMENT IN NEW
 OCCUPANCY. CONTACT THIS OFFICE @ (561)
 659-8096 EXT. 8221 TO ARRANGE AN
 INSPECTION OF EXISTING CONDITIONS AND
 TO DETERMINE WHAT WILL BE REQUIRED FOR
 FINAL APPROVAL.
 BE PREPARED TO PROVIDE EQUIPMENT
 TONNAGE AND OTHER INFORMATION NEEDED BY
 INSPECTOR TO ASSURE IF FAN SHUT DOWN BY
 DUCT SMOKE DETECTOR OR ANY FIRE DAMPERS
 ARE TO BE REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2001-02-14 Cont ID  
Sent By fknapp Date 2001-02-14 Time 09:23 Rev Time 0.00
Received By fknapp Date 2001-01-09 Time 14:28 Sent To  
Notes
2001-01-09 00:00:00*************DENIED*********************
 INSUFFICIENT INFORMATION INCLUDED FOR
 REVIEW. PROVIDE DETAILED MECHANICAL
 PLANS SHOWING EXISTING SYSTEM AND NEW
 WORK INVOLVED IN THIS PROJECT.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-12-19 Cont ID  
Sent By kstevens Date 2001-12-19 Time 15:38 Rev Time 0.50
Received By kstevens Date 2001-12-19 Time 15:38 Sent To  
Notes
2001-12-19 00:00:00REVISION - REMOVING HOT WATER FROM PLAN
 LETTER DATED SEP 6 2001.

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-02-14 Cont ID  
Sent By fknapp Date 2001-02-14 Time 09:25 Rev Time 0.00
Received By fknapp Date   Time   Sent To  
Notes
2001-02-14 00:00:00OK PER J.LEECH

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-01-08 Cont ID  
Sent By jleech Date 2001-01-08 Time 13:52 Rev Time 1.00
Received By mcarsill Date 2001-01-08 Time 13:52 Sent To  
Notes
2001-01-08 00:00:00DENIED;
  
 1.RISER DIAGRAM NOT TO CODE. SPC 914.
 CIRCUIT OR LOOP VENTING SHOULD BE USED
 FOR NEW PLUMBING. URINAL SHOULD HAVE
 ITS OWN VENT.
  
 2.SHOW A WATER RISER DIAGRAM.
  
 3.SHOW SQUIRE FOOTAGE CALCULATIONS AND
 FIXTURES REQUIRED TO COMPLY WITH SPC
 TABLE 407. SEE 407.1.3 FOR SQUIRE
 FOOTAGE YOU CAN DEDUCT.
  
 4.DRINKING FOUNTAINS ARE REQUIRED TO
 COMPLY WITH FACBC SECS. 4.1.3(10) AND
 4.15. PROVISIONS SHALL BE MADE FOR
 PEOPLE WHO HAVE TROUBLE BENDING OR
 STOOPING.
  
 5.LOUNGE SINK MUST COMPLY WITH FACBC
 4.24.1 THRU 4.24.7. SHOW ELEVATION
 DRAWINGS.
  
 6.WALLS AND FLOORS OF PUBLIC RESTROOMS
 SHALL BE LINED WITH NONABSORBENT
 MATERIAL TO A HEIGHT OF 4' ABOVE FLOOR
 SBC 1204.2.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT;8377