Plan Review Details - Permit 00120676
Plan Review Stops For Permit 00120676
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-02-08 Cont ID  
Sent By jwitmer Date 2001-02-08 Time 10:52 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-12-21 Cont ID  
Sent By lmartine Date 2000-12-21 Time 15:59 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-02-14 Cont ID  
Sent By dpalmer Date 2001-02-14 Time 13:01 Rev Time 0.00
Received By dpalmer Date 2001-02-14 Time 13:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-12-19 Cont ID  
Sent By dpalmer Date 2000-12-19 Time 16:51 Rev Time 0.00
Received By dpalmer Date 2000-12-19 Time 16:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-02-14 Cont ID  
Sent By mcarsill Date 2001-02-14 Time 14:34 Rev Time 0.00
Received By mcarsill Date 2001-02-14 Time 14:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-12-20 Cont ID  
Sent By mcarsill Date 2000-12-20 Time 10:15 Rev Time 0.00
Received By mcarsill Date 2000-12-20 Time 10:15 Sent To  
Notes
2001-01-08 00:00:001) INTERIOR FINISH IN TENANT SPACE IF
 SPRINKLERED CAN BE CLASS C.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-02-14 Cont ID  
Sent By pkrauss Date 2001-02-14 Time 11:35 Rev Time 0.33
Received By pkrauss Date 2001-02-14 Time 11:35 Sent To  
Notes
2001-02-14 00:00:00PROVISO:AS PER NFPA 90A 4-4.4.2, DUCT
 SMOKE DETECTOR SHALL BE TIED WITH
 BUILDING FIRE ALARM, IF BUILING FIRE
 ALARM DOES NOT EXIST, DUCT SMOKE
 DETECTORS SHALL ACTIVATED STROBE/ALARM
 IN OCCUPIED AREAS.
  
 AS PER 97 SMC 609.1.1, NO COMBUSTIBLES
 SHALL BE ABOVE CEILING IN RETURN AIR
 PLENUM.
  
 FIRE DAMPER IS REQUIRED FOR MOTORIZED
 DAMPER INTAKE OPENING FOR AHU 1 AS PER
 97 610.1.2 (CORRIDOR TO BE PROTECTED
 PER 97SBC 1006.2.2)

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-12-20 Cont ID  
Sent By ndenmark Date 2000-12-20 Time 08:09 Rev Time 0.33
Received By ndenmark Date 2000-12-20 Time 08:09 Sent To  
Notes
2001-01-08 00:00:00PROVISO:
 1. NO PVC OR OTHER COMBUSTIBLE CONSTRUC-
 TION ALLOWED IN MECH RM USED AS RETURN
 AIR PLENUM AREA.1997 SMC 609.1.1
 2. 10 FT MINIMUM REQUIRED BETWEEN OUT
 SIDE AIR INTAKE AND EXHAUST AIR OUTLET
 1997 SMC 506.1

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-02-07 Cont ID  
Sent By jleech Date 2001-02-07 Time 07:40 Rev Time 0.50
Received By jleech Date 2001-02-07 Time 07:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-12-21 Cont ID  
Sent By pschmitz Date 2000-12-17 Time 11:58 Rev Time 2.00
Received By lmartine Date   Time   Sent To  
Notes
2001-01-08 00:00:00PLUMBING PLAN REVIEW,PAUL SCHMITZ
 PROVISO
 (1) SHT A-1 BREAK RM #239 SINK TO COMPLY
 W/ FACBNC 4.24, SHOW ELEVATION DETAIL
 HGTH 34" ABOVE FF, BY 30" WIDE.
 KNEE CLEARANCE 27" HIGH, 30" WIDE,
 19" MAX DEPTH.
 (2) SHT A-1 H/C REST RM'S # 248,253 TO
 COMPLY W/FACBC 4.17.5 DOORS SHALL NOT
 SWING INTO THE CLEAR FLR SPACE OF ANY
 FIXTURE.
 (3) SHT P-1 NOTE (2) & (4) HOT & COLD
 WATER SUPPLY TO BE PROTECTRED WITH A
 RPZV, SPC 94 SEC 606.
 (4) SHT P-1 NOTE 16, AIR CHAMBERS TO
 COMPLY WITH SPC 94 SEC 607.8.3 TO BE
 READLY ACCESSIBLE AND RECHARGEABLE.
 END OF COMMENTS
  
  
 CHANGED TO PROVISO PER BILL STAPLES