| Plan Review Stops For Permit 00120295 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-01-19 |
Time |
11:20 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-12-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2000-12-20 |
Time |
09:21 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BUILDING PLAN REVIEW: | | | FLORIDA ACCESSIBILITY CODE: | | | 1). PASSENGER LOADING ZONE: 4.6.6:ACCESS | | | AISLE 60" X 20'-0". | | | 2).RAMPS: ADMINISTRATIVE CODE104.2.2 | | | DETAILS & DRAWINGS SHOWING STRUCTURAL | | | DETAILS, SLOPE, LENGTH, GAURDRAIL DETAIL | | | ENTRY DETAIL TO SALES TRAILER 4.13.8 | | | FL. ACC. CODE RAMP TO SALES TRAILER | | | TRANSSITION NOT TO EXCEED 3/4". | | | LANDINGS 4.8.4.2:ALL LANDINGS ON RAMPS | | | (BOTTOM OF RAMP)SHALL BE 72" OF STRAIGHT | | | & LEVEL CLEARENCE. | | | 3).FL. ACC. CODE 4.9.2: TREADS SHALL NOT | | | BE LESS THAN 11" WIDE AND OPENRISERS | | | ARE NOT PERMITTED. | | | S.B.C.1007.3.1 THE SUM OF 2 RISERS & 1 | | | TREAD SHALL NOT BE LESS THAN 24" & NOT | | | MORE THAN 25". | | | 4).ADMINISTRATIVE CODE 104.2.2: MOBILE | | | HOMES (USED FOR RESIDENTIAL UNITS) DO | | | NOT COMPLY WITH COMMERCIAL USAGE. SBC | | | TABLE 1604.1 RESIDENTIAL SLEEPING 30 PSF | | | LIVE LOAD VS 50 PSF OFFICES. THE DOORWAY | | | HALLS & BATHROOM MUST COMPLY WITH FL. | | | ACCESSIBILITY CODE WHICH RESIDENTIAL | | | MOBILE HOMES DO NOT. | | | S.S.553.35-553.42 MANUFACTURED BUILDINGS | | | MOBILE COMPLY WITH STATE BUILDING STAND- | | | ARDS.553.381 MANUFACTURES CERTIFICATION | | | NUMBER. | | | WE WILL NEED 2 SETS OF PRINTS, ALSO THE | | | TIE DOWN PLANS. WE WILL NEED THE MAXIMUM | | | PIER LOADS IN POUNDS BASED ON THE SOIL | | | VALUES. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-01-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-22 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-22 |
Time |
09:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-12-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-12 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-12 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT ELECTRICAL DETAIL | | | ON FEED TO THE TRAILER. NONE SHOWN | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 659-8096 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2001-01-31 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2001-01-31 |
Time |
09:13 |
Rev Time |
1.00 |
| Received By |
dlauderm |
Date |
2001-01-31 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2001-01-31 00:00:00 | PASSED WITH PROVISOS: | | | REVIEWED BY MOHAMMAD R. AMINI | | | 1. PASSED PER COMMENTS MADE BY | | | MANY GONZALEZ, TO THE ENGLE HOMES | | | REPRESENTATIVES. | | | 2. DRIVEWAY APPROACH MUST MEET CWPB | | | STANDARDS. SEE ATTACHED STANDARD |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2001-01-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-01-12 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-01-12 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-12-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-12-19 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-12-19 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) PLEASE PROVIDE IN WRITING HOW LONG | | | THE TRAILER IS EXPECTED TO REMAIN ON | | | SITE TO THE FIRE RESCUE DEPARTMENT. | | | 2) ELECTRIC POWERED SMOKE DETECTORS ARE | | | REQUIRED WITHIN THE TRAILER. | | | 3) PLEASE PROVIDE A PORTABLE FIRE | | | EXTINGUISHER FOR TRAILER WITH A CURRENT | | | SERVICE TAG. | | | 4) STAIRS TO COMPLY WITH BUILDING AND | | | FIRE CODE REQUIREMENTS. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-12-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-15 |
Time |
09:05 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-01-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-27 |
Time |
11:16 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2001-01-27 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-01-21 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2001-01-21 |
Time |
14:14 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-21 00:00:00 | PLUMBING PLAN REVIEW DENIED 2ND TIME | | | (1) SPC 94 SEC 104.3 DRAWINGS,SPECIFI- | | | CATIONS SHOWING LOCATION OF WATER AND | | | SANITARY SEWER CONNECTION,WITH A BACK | | | FLOW PREVENTER ON WATER SERVICE. LOCAL | | | ORDINANCE # 2853-95. | | | SEWER CONNECTION SPC 94 SEC 301.11.1 | | | WATER CONNECTION SPC 94 SEC 301.11.2 | | | END 0F COMMENTS,QUESTIONS CONTACT | | | PAUL SCHMITZ 561-659 8096-X 8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-12-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-12 |
Time |
19:12 |
Rev Time |
0.33 |
| Received By |
pschmitz |
Date |
2000-12-12 |
Time |
19:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO DISPOSAL SYSTEM FOR PLUMBING FIXTURES |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-12-12 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2000-12-12 |
Time |
09:52 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|