| Plan Review Stops For Permit 00120092 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2001-04-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-09 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-09 |
Time |
.6:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2001-04-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-04 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-04 |
Time |
15:46 |
Sent To |
|
|
| Notes |
| 2001-04-04 00:00:00 | PLANS ARE TO BE DRAWN BY THE ARCH/ENGIN | | | OF RECORD. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-22 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-22 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-12-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-19 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-19 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | CALLED ARCH AND WAITING FOR INFORMATION | | | FOR PLANS TO CORRELATE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-12-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-07 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-07 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************** UNSAT *************** | | | | | | 1)NOTE: PLEASE SEE 210-8-A-6 AND SHOW | | | ALL OUTLETS SERVING KITCHEN COUNTER- | | | SPACE AS GFI/ GFI PROTECTED. | | | | | | 2)NOTE: PLEASE NOTE THAT NO SECOND FLOOR | | | ELECTRICAL WAS SUBMITTED FOR CARRIAGE | | | HOUSE.?? | | | | | | 3)NOTE: PLEASE SEE 210-8 FOR GARAGE | | | GFI PROTECTION. | | | | | | 4)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | AND SHOW RISER DIAGRAM TO SHOW EXISTING | | | SERVICE EQUIPMENT SIZES. PLAN SHOWING | | | NEW POOL/ A/C EQUIPMENT. PLEASE SUBMIT | | | NEW PANEL SCHEDULES. | | | | | | 5)NOTE: PLEASE NOTE MISSING GFI OUTLET | | | FOR A/C EQUIPMENT. PER MECH CODE 300.9 | | | | | | 6)NOTE:PLEASE SEE LOCATION OF OUTLET | | | SERVING BATH IN CARR. HOUSE. PER 210-52D | | | AND SEE 210-11-C-3 FOR REQ`MNETS OF | | | CIRCUIT. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-12-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-06 |
Time |
14:36 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-12-06 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO A/C PLANS. A/C CONTRACTOR TO SUBMIT | | | PLAN WITH PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-12-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-15 |
Time |
08:17 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-12-15 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-12-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-06 |
Time |
14:38 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-12-08 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED; | | | 1.GAS WATER HEATER UNDER STAIRS MUST | | | BE VENTED TO OUTSIDE AND WATER HEATER | | | IS IN A CONFINED SPACE, SHOW HOW | | | HOW COMBUSTION AIR WILL VENTED TO W/H. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096EXT.8377 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-12-20 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-12-20 |
Time |
16:08 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-12-20 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | *************BUILDING PROVISO*********** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI PRODUCT APPROVALS FOR: | | | WOOD PANEL SWING EXTERIOR DOORS | | | ROUND TOP WINDOWS | | | DOUBLE FRENCH DOORS WITH SIDELITE | | | ASSEMBLY. | | | | | | 2)PROVIDE SITE SPECIFIC PRODUCT APPROVAL | | | FORM FOR GARAGE DOORS. | | | | | | PLEASE SUBMIT PRIOR TO INSTALLATION. | | | | | | 3)PROVIDE MECHANICAL DRAWINGS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | 4)POOL AND POOL DECK UNDER SEPARATE | | | PERMIT. | | | | | | 5)FENCE UNDER SEPARATE PERMIT. | | | | | | ANY QUESTIONS PLEASE CALL: | | | FRANK KNAPP | | | CITY OF WEST PALM BEACH | | | BUILDING PLAN REVIEW | | | 659-8096 EXT 8392 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-12-08 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-12-08 |
Time |
11:24 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-12-08 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | *************BUILDING UNSAT************* | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI PRODUCT APPROVALS FOR: | | | SKYLITE | | | MULLIONS | | | ROUND TOP WINDOWS | | | WOOD PANEL DOORS | | | GARAGE DOORS | | | DOUBLE FRENCH DOORS WITH SIDELITE | | | | | | 2)PROVIDE UL LISTING FOR PIERSON GAS | | | FIREPLACE LOG. | | | | | | 3)PROVIDE STORM PANEL INFORMATION FOR | | | ALL NON IMPACT GLAZE OPENINGS. | | | | | | 4)PROVIDE ENERGY CALCULATIONS | | | | | | 5)PROVIDE AT LEAST ONE BATHROOM ON | | | HABITABLE GRADE LEVEL WITH A DOOR THAT | | | HAS A 29" CLEAR OPENING. | | | | | | 6)PROVIDE MECHANICAL DRAWINGS WITH | | | MECHANICAL PERMIT APPLICATION. | | | | | | 7)PROVIDE ORIGINAL PLANS REVISED WITH | | | DELETION OF TRELLIS. | | | | | | NOTE: | | | | | | POOL AND POOL DECK UNDER SEPARATE PERMIT | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | | ISSUED,IMPACT FEES MUST BE PAID TO PALM | | | BEACH CO.,THE PERMIT PLANS STAMPED BY | | | THEM AND THE RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. | | | | | | ANY QUESTIONS PLEASE CALL: | | | FRANK KNAPP | | | CITY OF WEST PALM BEACH | | | BUILDING PLAN REVIEW | | | 561-659-8096 EXT 8392 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-12-05 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2000-12-05 |
Time |
13:13 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|