Review Stop E ELECTRICAL
Rev No 5 Status P Date 2001-04-09 Cont ID  
Sent By dpalmer Date 2001-04-09 Time 17:23 Rev Time 0.00
Received By dpalmer Date 2001-04-09 Time .6:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2001-04-04 Cont ID  
Sent By dpalmer Date 2001-04-04 Time 15:46 Rev Time 0.00
Received By dpalmer Date 2001-04-04 Time 15:46 Sent To  
Notes
2001-04-04 00:00:00PLANS ARE TO BE DRAWN BY THE ARCH/ENGIN
 OF RECORD.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-12-22 Cont ID  
Sent By dpalmer Date 2000-12-22 Time 10:03 Rev Time 0.00
Received By dpalmer Date 2000-12-22 Time 10:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-12-19 Cont ID  
Sent By dpalmer Date 2000-12-19 Time 14:11 Rev Time 0.00
Received By dpalmer Date 2000-12-19 Time 14:11 Sent To  
Notes
2001-01-08 00:00:00CALLED ARCH AND WAITING FOR INFORMATION
 FOR PLANS TO CORRELATE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-12-07 Cont ID  
Sent By dpalmer Date 2000-12-07 Time 14:57 Rev Time 0.00
Received By dpalmer Date 2000-12-07 Time 14:57 Sent To  
Notes
2001-01-08 00:00:00***************** UNSAT ***************
  
 1)NOTE: PLEASE SEE 210-8-A-6 AND SHOW
 ALL OUTLETS SERVING KITCHEN COUNTER-
 SPACE AS GFI/ GFI PROTECTED.
  
 2)NOTE: PLEASE NOTE THAT NO SECOND FLOOR
 ELECTRICAL WAS SUBMITTED FOR CARRIAGE
 HOUSE.??
  
 3)NOTE: PLEASE SEE 210-8 FOR GARAGE
 GFI PROTECTION.
  
 4)NOTE: PLEASE SUBMIT LOAD CALCULATIONS
 AND SHOW RISER DIAGRAM TO SHOW EXISTING
 SERVICE EQUIPMENT SIZES. PLAN SHOWING
 NEW POOL/ A/C EQUIPMENT. PLEASE SUBMIT
 NEW PANEL SCHEDULES.
  
 5)NOTE: PLEASE NOTE MISSING GFI OUTLET
 FOR A/C EQUIPMENT. PER MECH CODE 300.9
  
 6)NOTE:PLEASE SEE LOCATION OF OUTLET
 SERVING BATH IN CARR. HOUSE. PER 210-52D
 AND SEE 210-11-C-3 FOR REQ`MNETS OF
 CIRCUIT.
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-12-06 Cont ID  
Sent By jleech Date 2000-12-06 Time 14:36 Rev Time 0.25
Received By jleech Date 2000-12-06 Time 14:36 Sent To  
Notes
2001-01-08 00:00:00NO A/C PLANS. A/C CONTRACTOR TO SUBMIT
 PLAN WITH PERMIT APPLICATION.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-12-15 Cont ID  
Sent By jleech Date 2000-12-15 Time 08:17 Rev Time 0.33
Received By jleech Date 2000-12-15 Time 08:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-12-08 Cont ID  
Sent By jleech Date 2000-12-06 Time 14:38 Rev Time 0.33
Received By jleech Date 2000-12-08 Time 10:47 Sent To  
Notes
2001-01-08 00:00:00DENIED;
 1.GAS WATER HEATER UNDER STAIRS MUST
 BE VENTED TO OUTSIDE AND WATER HEATER
 IS IN A CONFINED SPACE, SHOW HOW
 HOW COMBUSTION AIR WILL VENTED TO W/H.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096EXT.8377

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-12-20 Cont ID  
Sent By fknapp Date 2000-12-20 Time 16:08 Rev Time 4.00
Received By fknapp Date 2000-12-20 Time 16:07 Sent To  
Notes
2001-01-08 00:00:00 
  
 *************BUILDING PROVISO***********
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI PRODUCT APPROVALS FOR:
 WOOD PANEL SWING EXTERIOR DOORS
 ROUND TOP WINDOWS
 DOUBLE FRENCH DOORS WITH SIDELITE
 ASSEMBLY.
  
 2)PROVIDE SITE SPECIFIC PRODUCT APPROVAL
 FORM FOR GARAGE DOORS.
  
 PLEASE SUBMIT PRIOR TO INSTALLATION.
  
 3)PROVIDE MECHANICAL DRAWINGS WITH
 MECHANICAL PERMIT APPLICATION.
  
 4)POOL AND POOL DECK UNDER SEPARATE
 PERMIT.
  
 5)FENCE UNDER SEPARATE PERMIT.
  
 ANY QUESTIONS PLEASE CALL:
 FRANK KNAPP
 CITY OF WEST PALM BEACH
 BUILDING PLAN REVIEW
 659-8096 EXT 8392

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-12-08 Cont ID  
Sent By fknapp Date 2000-12-08 Time 11:24 Rev Time 4.00
Received By fknapp Date 2000-12-08 Time 11:21 Sent To  
Notes
2001-01-08 00:00:00 
 *************BUILDING UNSAT*************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI PRODUCT APPROVALS FOR:
 SKYLITE
 MULLIONS
 ROUND TOP WINDOWS
 WOOD PANEL DOORS
 GARAGE DOORS
 DOUBLE FRENCH DOORS WITH SIDELITE
  
 2)PROVIDE UL LISTING FOR PIERSON GAS
 FIREPLACE LOG.
  
 3)PROVIDE STORM PANEL INFORMATION FOR
 ALL NON IMPACT GLAZE OPENINGS.
  
 4)PROVIDE ENERGY CALCULATIONS
  
 5)PROVIDE AT LEAST ONE BATHROOM ON
 HABITABLE GRADE LEVEL WITH A DOOR THAT
 HAS A 29" CLEAR OPENING.
  
 6)PROVIDE MECHANICAL DRAWINGS WITH
 MECHANICAL PERMIT APPLICATION.
  
 7)PROVIDE ORIGINAL PLANS REVISED WITH
 DELETION OF TRELLIS.
  
 NOTE:
  
 POOL AND POOL DECK UNDER SEPARATE PERMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED,IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.
  
 ANY QUESTIONS PLEASE CALL:
 FRANK KNAPP
 CITY OF WEST PALM BEACH
 BUILDING PLAN REVIEW
 561-659-8096 EXT 8392

Review Stop Z ZONING
Rev No 1 Status P Date 2000-12-05 Cont ID  
Sent By sgraham Date 2000-12-05 Time 13:13 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***