| Plan Review Stops For Permit 00111378 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-01-25 |
Time |
16:34 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-25 00:00:00 | PROVISO: GLAZED EXTERIOR OPENINGS WILL | | | REQUIRE PRODUCT APPROVAL REPORTS AS WELL | | | AS SEPERATE PERMITS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-12-21 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-12-21 |
Time |
10:45 |
Rev Time |
99.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | LETTER W/APPLICATION |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-12-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-14 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-14 |
Time |
18:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2001-03-07 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-03-07 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-03-07 |
Time |
08:03 |
Sent To |
|
|
| Notes |
| 2001-03-07 00:00:00 | 1) COULD NOT LOCATE FIRE ALARM SYSTEM | | | EQUIPMENT WITHIN TENANT SPACE. CALLED | | | CONTRACTOR ON 3-06-01 AND ADVISED THEM | | | OF THIS. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-01-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-01-23 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-01-23 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2001-01-23 00:00:00 | 1) IT APPEARS THAT THE PREVIOUS PLAN | | | REVIEW COMMENTS HAVE NOT BEEN | | | ADDRESSED. PLEASE ADDRESS THE COMMENTS | | | PROVIDED TO YOU BY THE FIRE RESCUE | | | DEPARTMENT. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-12-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-12-11 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-12-11 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO FIRE SPRINKLER DRAWINGS PROVIDED | | | WITH PLANS. | | | 2) NO FIRE ALARM EQUIPMENT SHOWN ON | | | PLANS. FIRE ALARM SYSTEM LEGEND LOCATED | | | ON PLANS BUT NO DEVICES COULD BE FOUND. | | | 3) NO INTERIOR FINISH INFORMATION | | | INCLUDED IN PLANS. | | | 4) DOOR TO DRESSING ROOM 1, HANDICAPPED | | | APPEARS TO INTERFERE WITH EXITING WHEN | | | DOOR IS OPENED. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-02-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-02-06 |
Time |
08:27 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-02-06 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2001-02-06 00:00:00 | PROVISO: | | | 1. FIELD VERIFY EXISTING FIRE DAMPERS | | | ATTENANT SEPARATION WALL. | | | 2. LOCAL CODE REQUIRES MINIMUM 18" | | | C;EARANCE BETWEEN ROOF SURFACE AND | | | BOTTOM OF SUPPORT STRUCTURE OF STAND. | | | 3. AHU TO HAVE ACCESS FOR SERVICE AND | | | THE REMOVAL OF EQUIPMENT PER 1997 SMC | | | 304.2.1 | | | 4. OVERFLOW PROTECTION REQUIRED FOR AHU | | | PER 1997 SMC 304.8.6 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-12-20 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-12-20 |
Time |
13:09 |
Rev Time |
0.50 |
| Received By |
ndenmark |
Date |
2000-12-20 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************DENIED********************** | | | 1. PROVIDE INFORMATION ON CONDENSING | | | UNIT LOCATION AND REFRIGERANT PIPING | | | LOCATION THROUGH BUILDING | | | 2. AHU TO HAVE ACCESS FOR SERVICE AND | | | THE REMOVAL OF EQUIPMENT AS 1997 SMC | | | 304.2.1 PROVIDE SERVICE CLEARANCE | | | REQUIREMENTS PER MANUFACTURES INSTALLATI | | | ON INSTRUCTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-03-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2001-03-09 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-09 00:00:00 | APPROVED BY JOHN LEECH, SEE APPL. AND | | | PLANS.LM3/9/01 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-12-10 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-12-10 |
Time |
13:35 |
Rev Time |
2.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEW PAUL SCHMITZ | | | DENIED | | | (1) SHT A-2 DRESSING RM #1 TO COMPLY W/ | | | FACBC-97 SEC 4.35.2 A CLEAR FLR SPACE TO | | | ALLOW A PERSON IN A WHEEL CHAIR TO MAKE | | | A 180-DEGREE TURN, SHALL BE PROVIDED. | | | EVERY ACCESSIBLE DRESSING RM SHALL HAVE | | | A FIXED BENCH, 24" X 48" AT 17"TO 19" | | | ABOVE FF. | | | (2) SHT A-2 H/C REST RM'S SHALL COMPLY | | | W/FACBC 4.1,4.2,4.3,SPC 94 SEC 407.2.2 | | | REST RM'S SHALL BE INDEBILY POSTED FOR | | | INTENDED USE, BE AVILABLE TO PATRONS | | | WITH OUT RESTRICTION, TO HAVE A CLEARLY | | | DEFINED ROUTE ON THE PLANS. | | | (3) SHT P-2 AIR CHAMBERS TO COMPLY WITH | | | SPC 94 SEC 607.8.3, TO BE ACCESSIBLE & | | | RECHARGEABLE. | | | END OF COMMENTS PAUL SCHMITZ | | | 561-659-8096 X 8233 |
|
|