| Plan Review Stops For Permit 00111182 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-01-08 |
Time |
14:32 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-12-11 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-12-11 |
Time |
11:41 |
Rev Time |
2.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 12/11/00 DENIED AS PER EMAIL FROM | | | DEAN LAUDERMILK ATTACHED TO PERMIT | | | APPLICATION. WRS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2001-01-19 |
|
|
Cont ID |
|
| Sent By |
lsmith |
Date |
2001-01-19 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-19 00:00:00 | PER DVP NO ELECTRIC TO BE CONSIDERED FOR | | | THIS PERMIT.ANY ELECTRIC TO BE APPLIE | | | D FOR SEPARATELY. 1/8/01 LS 1/19/01 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-01-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-08 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-08 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ********************UNSAT ************** | | | | | | | | | | | | 1)NOTE: STILL NO ELECTRICAL DETAIL | | | SHOWN FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-13 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-13 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SUBMIT MORE ELECTRICAL | | | DETAIL FOR PLAN REVIEW. | | | | | | 2)NOTE: CONDUIT SIZES,WIRE, SERVICE DISC | | | -CONNECT? AIC RATINGS,,,,ETC ETC | | | | | | 3)NOTE: GROUNDING ELECTRODE SYSTEM.????? | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2001-04-09 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2001-04-09 |
Time |
11:37 |
Rev Time |
1.50 |
| Received By |
mamini |
Date |
2001-04-09 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2001-04-09 00:00:00 | PASSED: | | | 1. APPROVED FOR REVISION TO DRAINAGE AND | | | UTILITIES ON NORTH PORTION OF THE | | | PROJECT SITE. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2001-02-02 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2001-02-02 |
Time |
15:56 |
Rev Time |
1.50 |
| Received By |
dlauderm |
Date |
2001-02-02 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2001-02-02 00:00:00 | PASSED WITH PROVISOS: | | | REVIEW BY MOHAMMAD R. AMINI | | | 1. PLEASE REFER TO PREVIOUSE REVIEW | | | COMMENTS DATED 01/02/01. SEE ATTACHED | | | SHEET. | | | IF ANY QUESTIONS PLEASE FEEL FREE TO | | | CONTACT OUR OFFICE. 561 569 8096 | | | EXT. 8492 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2001-01-02 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2001-01-02 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
dlauderm |
Date |
2000-12-22 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PASSED WITH PROVISOS: | | | DUMPSTER DETAIL IS NOT TO BE USED.THE | | | SITE WILL USE A COMPACTOR. | | | CONSTRUCTION OF THE WATER AND SANITARY | | | SEWER SYSTEM CAN NOT START TILL THE | | | DEP/PBC HEALTH DEPARTMENT HAVE PERMITTED | | | THE PROJECT. | | | STORM WATER SYSTEM CAN BE INSTALLED WITH | | | THE UNDERSTANDING THAT THE OWNER, | | | ENGINEER AND CONTRACTOR IS WORKING AT | | | RISK.THE SFWMD HAS NOT APPROVED THIS | | | LATEST PLAN AND, AT COST TO THE OWNER, | | | THE SYSTEM WILL NEED TO BE INSTALLED TO | | | A PLAN APPROVED BY SFWMD. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2001-02-05 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-02-05 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-02-05 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2001-02-05 00:00:00 | 1) FIRE HYDRANTS ARE TO BE WET PRIOR | | | TO, DURING, AND AFTER CONSTRUCTION. FIRE | | | LINES AND HYDRANTS ARE TO BE APPROVED | | | BY UTILITIES PRIOR TO ACTIVATING THEM. | | | 2) FIRE HYDRANTS ARE TO MEET CITY | | | UTILITY AND FIRE RESCUE STANDARDS. | | | 3) UNDERGROUND FIRE LINES TO BE PRESSURE | | | TESTED AT 200 PSI FOR TWO HOURS. | | | 4) WHILE THE BUILDING IS UNDER | | | CONSTRUCTION, SUITABLE ACCESS ROADS ARE | | | TO BE PROVIDED FOR FIRE AND PARAMEDICAL | | | PURPOSES. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT 8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2001-01-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-01-19 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-01-19 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2001-01-03 |
|
|
Cont ID |
|
| Sent By |
rturnque |
Date |
2001-01-03 |
Time |
10:30 |
Rev Time |
0.20 |
| Received By |
rturnque |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVIDE 20 FEET FIRE DEPARTMENT ACCESS | | | AT |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-12-13 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-12-13 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) FIRE DEPARTMENT ACCESS IS TO BE AT | | | LEAST 20 FEET IN CLEAR WIDTH AND BE | | | ABLE TO SUPPORT FIRE AND PARAMEDICAL | | | EQUIPMENT. SOME AREAS INDICATES 12 FEET | | | IN CLEAR WIDTH THAT DOES NOT MEET | | | MINIMUM CODE REQUIREMENTS. | | | 2) FIRE HYDRANTS AND UNDERGROUND | | | UTILITIES TO COMPLY WITH NFPA 24. | | | 3) PLEASE SHOW ALL FIRE HYDRANT | | | LOCATIONS ON EXECUTIVE CENTER DRIVE | | | EXTENSION. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-12-31 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-12-31 |
Time |
14:55 |
Rev Time |
2.50 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PROVISO | | | (1) APPROVAL OF THE DEPT OF ENVIROMENTAL | | | PROTECTION AND THE PALM BEACH COUNTY | | | HEALTH DEPT.BEFORE STARTING WORK ON THE | | | WATER AND WASTE WATER SYSTEMS. | | | (2) ALL WATER AND WASTE WATER ON PRIVATE | | | PROPERTY AND IN EASMENTS,NOT OWNED BY | | | THE CITY OF WEST PALM BEACH,SHALL BE | | | INSTALLED,TESTED AND INSPECTED,TO THE | | | CITY OF WEST PALM BEACH UTILITY STANDARD | | | AND SPECIFICATIONS, | | | (3) POTABLE WATER AND WASTE WATER SYSTEM | | | TO BE INSPECTED BUY CONSTRUCTION SERVICE | | | DEPARTMENT.( SAME AS NOTE #2) | | | (4) FIRE LINES TO BE INSPECTED BY WEST | | | PALM FIRE DEPT. ( SAME AS NOTE #2) | | | (5) STORM WATER TO BE INSPECTED BY | | | CONSTRUCTION SERVICES DEPARTMENT,LIMITED | | | TO 5 FT. OUT SIDE OF BUILDING. | | | END OF COMMEENTS, QUESTIONS,CONTACT | | | PAUL SCHMITZ 561-659-8096 X 8233 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-12-07 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2000-12-07 |
Time |
10:28 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|