Plan Review Details - Permit 00111179
Plan Review Stops For Permit 00111179
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2001-08-31 Cont ID  
Sent By jwitmer Date 2001-08-31 Time 07:28 Rev Time 1.00
Received By jwitmer Date 2001-08-31 Time 07:27 Sent To  
Notes
2001-08-31 00:00:00REVISION SUBMITTED8/7/01 OK JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2001-07-30 Cont ID  
Sent By jwitmer Date 2001-07-30 Time 09:31 Rev Time 0.00
Received By jwitmer Date 2001-08-20 Time 15:08 Sent To  
Notes
2001-07-30 00:00:00BUILDING PLAN REVIEW
 00111179
 2308 N DIXIE
  
 1)- FL AESSIBILITY CODE 4.4.3.8
 CHANGE IN GRADE, FRONT AND SIDE ENTRY SH
 OW A STOOP, A RAMP OR OTHER OF VERTICAL
 ACCESSIBILITY WILL BE REQUIRED.
  
 JIM WITMER
 (561) 659-8096X 8412

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2001-03-20 Cont ID  
Sent By jwitmer Date 2001-03-20 Time 11:35 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
2001-03-20 00:00:00BUILDING:
 1)- FL ACCESSIBLITY CODE 4.4.3.8 CHANGE
 IN GRADE, FRONT AND SIDE ENTRY SHOWS A
 STOOP, A RAMP OR OTHER FORM OF VERTICAL
 ACCESSIBILITY WILL BE REQUIRED.
  
 2)- BACKING BEHIND THE WATER CLOSETS
 WHERE THERE IS NO SIDE WALL FOR GRAB
 RAIL SUPPORT, SEE DETAIL.
  
 BUILDING PLAN REVIEW
 JIM WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-12-06 Cont ID  
Sent By lsmith Date 2000-11-29 Time 07:22 Rev Time 0.50
Received By lsmith Date   Time   Sent To  
Notes
2001-01-08 00:00:00NEED PRODUCT APPROVALS: DOORS ON PLANS
 NOT ON PERMIT APP.

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2001-10-25 Cont ID  
Sent By tjonseck Date 2001-10-25 Time 15:40 Rev Time 0.25
Received By tjonseck Date   Time   Sent To  
Notes
2001-10-25 00:00:00SEPERATE PERMIT FOR ELECTRICAL SEE
 PERMIT # 01070172

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-03-12 Cont ID  
Sent By dpalmer Date 2001-03-12 Time 18:50 Rev Time 0.00
Received By dpalmer Date 2001-03-12 Time 18:50 Sent To  
Notes
2001-03-12 00:00:00****************** UNSAT *************
  
 1)NOTE: PLEASE NOTE ELECTRICAL PLANS
 NEED TO BE SUBMITTED WITH AN ELECTRICAL
 PERMIT APPLICATION. PLEASE NOTE PLANS
 AHVE NEVER HAD AN ELECTRICAL REVIEW.
 PERMIT IS A MISC PERMIT. VALUE OF WORK
 NEEDS TO BE INCREASED. ORIG VALUE AT
 $6500??
  
 2)NOTE: PLEASE NOTE THAT YOU ARE SHOWING
 PANELS FEEDING MORETHAN ONE TENANT
 SPACE?.
 THIS IS NOT PERMITTED. PLEASE CLARIFY.
  
 NEEDS TO REVIEW BY ZONING FOR USE SHOWN.
  
 PLEASE SUBMIT ALL THE INFORMATION NEEDED
 AND SUBMIT FOR APPROPIATE PERMITS AND
 UP VALUE OF EXISTING .
  
 PLEASE SUBMIT THE ABOVE. IF THERE ARE
 ANY QUESTIONS PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 561-659-8096 EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2001-08-20 Cont ID  
Sent By mcarsill Date 2001-08-20 Time 08:48 Rev Time 0.00
Received By mcarsill Date 2001-08-20 Time 08:48 Sent To  
Notes
2001-08-20 00:00:001) EXIT SIGNS AND EMERGENCY LIGHTING
 REQUIRED.
 2) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED IN EACH SLEEPING ROOM. WHEN
 ACTIVATED, THESE DEVICES ARE TO BE
 AUDIBLE IN THE SLEEPING ROOMS OF THAT
 UNIT.
 3) TENANT SEPARATIONS TO COMPLY WITH
 BUILDING CODE REQUIREMENTS.
  
 APPROVED PROVISO:
  
 MIKE CARSILLO, CAPTAIN
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2001-07-25 Cont ID  
Sent By mcarsill Date 2001-07-25 Time 15:22 Rev Time 0.00
Received By mcarsill Date 2001-07-25 Time 15:22 Sent To  
Notes
2001-07-25 00:00:001) ELECTRIC POWERED SMOKE DETECTORS
 REQUIRED IN EACH APARTMENT. WHEN
 ACTIVATED THESE DETECTORS ARE TO BE
 AUDIBLE THROUGHOUT THE UNIT.
 2) WALLS ARE TO BE 1/2 HOUR FIRE
 RESISTIVE AND HAVE AT LEAST 20 MINUTE
 FIRE DOORS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2001-03-13 Cont ID  
Sent By mcarsill Date 2001-03-13 Time 12:28 Rev Time 0.00
Received By mcarsill Date 2001-03-13 Time 12:28 Sent To  
Notes
2001-03-13 00:00:001) NO FIRE SPRINKLER DRAWINGS PROVIDED
 WITH PLANS.
 2) PLANS INDICATE ONE HOUR RATED FIRE
 DOORS. DOOR CLOSERS AND FRAMES HAVE
 NOT BEEN MENTIONED ON THE PLANS.
 3) HOW ARE THE DRYERS VENTED.
 4) WHAT FLOOR OF THE BUILDING IS THE
 WORK TAKING PLACE ONE.
 5) ARE THERE ANY FIRE ALARM DEVICES
 IN THE AREA.
 6) NO INTERIOR FINISH INFORMATION WITH
 PLANS.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop P PLUMBING
Rev No 2 Status N Date 2001-10-25 Cont ID  
Sent By tjonseck Date 2001-10-25 Time 15:42 Rev Time 0.25
Received By tjonseck Date   Time   Sent To  
Notes
2001-10-25 00:00:00SEPERATE PLUMB PERMIT SEE PERMIT
 #01070017 DR

Review Stop P PLUMBING
Rev No 1 Status F Date 2001-03-14 Cont ID  
Sent By jleech Date 2001-03-14 Time 16:58 Rev Time 1.00
Received By jleech Date 2001-03-14 Time 16:58 Sent To  
Notes
2001-03-14 00:00:00DENIED;
  
 NOT ENOUGH INFORMATION. WHAT IS THE
 EXTENT OF PLUMBING WORK? WHAT FLOOR IS
 BEING REMODELED? IF ANY PLUMBING DEMO
 WORK IS TO BE DONE PLUMBING PERMITS ARE
 REQUIRED.
  
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT.8377