| Plan Review Stops For Permit 00110906 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-07-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-23 |
Time |
11:05 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2001-04-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-04-30 |
Time |
18:36 |
Rev Time |
0.65 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2001-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-07-18 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-07-18 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2001-07-18 00:00:00 | ****************** UNSAT *********** | | | | | | 1)NOTE: PLEASE NOTE THAT PER FS/FAC | | | PLANS ARE TO HAVE A TITLE BLOCK AND | | | SIGNED , DATEDAND SEALED BY THE | | | ARCH/ ENGINEER OF RECORD. | | | PER 481.221 AND 61G15-23.002, | | | 471.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EX 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-04-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-19 |
Time |
21:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-19 |
Time |
21:09 |
Sent To |
|
|
| Notes |
| 2001-04-19 00:00:00 | REV FOR BACK BATH AND RETREAT AREA ONLY, | | | PLANS HAVE NOT BEEN RE-DRAWN YET. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-01-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-03 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-03 |
Time |
18:58 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** REVISION NEEDED!! ****** | | | | | | | | | 1)NOTE: PLANS ARE TO BE REVISED WITH | | | ALL REDLINED ITEMS AND AS-BUILTS. | | | PLANS ARE TO BE SUBMITTED AND REVIEWED | | | BEFORE ANY FINAL ELECTRICAL INSPECTION | | | IS CALLED IN. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-28 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-28 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | *************** UNSAT ****************** | | | | | | 1)NOTE: ALL OUTLETS SERVING KITCHEN | | | COUNTERSPACE ARE TO BE SHOWN AS GFI/GFI | | | PROTECTED PER 210-8-A-6 | | | | | | 2)NOTE: PLEASE SEE MISSING GFI FOR POWD- | | | -ER ROOM. PER 210-52D AND 210-11-C3 | | | | | | 3)NOTE: PLEASE SEE MISSING OUTLETS PER | | | 210-52 FOR 2` OF WALL SPACE. | | | | | | 4)NOTE: SMOKE DETECTOR REQ`D INSIDE AND | | | OUTSIDE ALL SLEEPING ROOMS OF NEW CONST- | | | -RUCTION. NFPA-72 2-2.1.1.1 | | | | | | 5)NOTE: PLEASE NOTE AS PER 250-50 NEW | | | BLDG STEEL AT NEW GARAGE TO BE BONDED. | | | PLEASE SHOW WITH COLD WATER. | | | | | | 6)NOTE: PLEASE NOTE THAT NOW A NEW SERV- | | | -ICE IS BEING INSTALLED. PLEASE PROVIDE | | | AIC RATINGS FOR ALL NEW EQUIPMENT BEING | | | INSTALLED. MUST BE RATED FOR THE AVAIL- | | | ABLE FAULT CURRENT PER 110-9. | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-07-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-07-16 |
Time |
13:04 |
Rev Time |
0.30 |
| Received By |
pkrauss |
Date |
2001-07-16 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2001-07-16 00:00:00 | MECH PERMIT 01010268 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-08 |
Time |
15:23 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-01-08 |
Time |
08:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-30 |
Time |
16:35 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-11-30 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO A/C DRAWINGS A/C DRAWINGS REQUIRED | | | WITH A/C APPLICATION BY A/C CONTRACTOR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-07-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-07-16 |
Time |
19:32 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-07-16 |
Time |
19:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-04-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-04-26 |
Time |
18:08 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-04-26 |
Time |
18:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-30 |
Time |
16:37 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-11-30 |
Time |
16:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2001-01-08 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2001-01-08 |
Time |
11:29 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2001-01-08 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | *************BUILDING PROVISO*********** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | MULLIONS | | | ROOF COVERING UNDER SEPARATE PERMIT | | | | | | 2)PROVIDE FLOOD ZONE ELEVATION | | | CETIFICATE FOR NEW GARAGE WITH BFE OF | | | 7.5' | | | | | | 3)PROVIDE SEPARATE PERMIT FOR NEW DRIVE. | | | | | | ANY QUESTIONS PLEASE CALL, | | | FRANK KNAPP | | | PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 659-8096 EXT 8392 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-12-19 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-12-19 |
Time |
14:13 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-12-19 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | *************BUILDING UNSAT************* | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | ALL SH WINDOWS | | | MULLIONS | | | FRENCH DOORS WITH SIDELITES | | | ALL EXTERIOR SWING DOORS | | | GARAGE DOORS | | | ROOF COVERING UNDER SEPARATE PERMIT | | | | | | 2)PROVIDE STORM PANEL INSTALLATION | | | SCHEDULE AND KEY PLAN WITH SPECIFIC | | | MOUNTING AND ANCHORS TO BE USED. | | | | | | 3)PROVIDE ENERGY CALCULATIONS | | | | | | 4)PROVIDE 2 CURRENT SIGN AND SEALED | | | SURVEYS WITH ALL IMPROVEMENTS TO BE MADE | | | SHOWN ON SURVEY. | | | | | | 5)PROVIDE 1 BATHROOM DOOR WITH 29" NET | | | CLEAR OPENING ON HABITABLE GRADE LEVEL | | | FACBC 4.22.2 | | | | | | 6)PROVIDE CEILING HEIGHT TO COMPLY WITH | | | 1997 SBC 1203.2 CLARIFY +- 7'BOT OF BEAM | | | HABITABLE SPACES CEILING HEIGHT SHALL BE | | | 7'6" | | | | | | 7)PROVIDE DETAILS OF NEW WALL CONNECTION | | | TO EXISTING WALLS. | | | | | | 8)PROVIDE ROOF SHEATHING NAILING ZONES | | | THAT COMPLY WITH CITY AMENDMENTS FIG. | | | 2306.1 SBC 1606 | | | | | | 9)PROVIDE SPECIFIC WINDOW,EXTERIOR DOORS | | | AND GARAGE DOORS BUCK CONNECTION DETAILS | | | FOR WINDLOAD COMPLIANCE. SBC 1606 | | | | | | 10)PROVIDE A5 FLOOD ZONE ELEVATION | | | CERTIFICATE WITH NEW CONSTRUCTION FLOOR | | | ELEVATION OF 7.5' | | | | | | 11)PROVIDE NOC RECORDED WITH CLERK OF | | | COURT BEFORE BUILDING PERMIT CAN BE | | | ISSUED. | | | | | | 12)PROVIDE PAID IMPACT FEE RECEIPT. | | | | | | 13)PROVIDE DRIVE UNDER SEPARATE PERMIT. | | | | | | ANY QUESTIONS PLEASE CALL | | | FRANK KNAPP | | | BUILDING PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 659-8096 EXT 8392 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-12-19 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-12-19 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | OK PER S.GRAHAM |
|
|