Plan Review Details - Permit 00110906
Plan Review Stops For Permit 00110906
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-07-23 Cont ID  
Sent By jwitmer Date 2001-07-23 Time 11:05 Rev Time 0.50
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2001-04-30 Cont ID  
Sent By jwitmer Date 2001-04-30 Time 18:36 Rev Time 0.65
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2001-07-18 Cont ID  
Sent By dpalmer Date 2001-07-18 Time 13:44 Rev Time 0.00
Received By dpalmer Date 2001-07-18 Time 13:44 Sent To  
Notes
2001-07-18 00:00:00****************** UNSAT ***********
  
 1)NOTE: PLEASE NOTE THAT PER FS/FAC
 PLANS ARE TO HAVE A TITLE BLOCK AND
 SIGNED , DATEDAND SEALED BY THE
 ARCH/ ENGINEER OF RECORD.
 PER 481.221 AND 61G15-23.002,
 471.025
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EX 8372

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-04-19 Cont ID  
Sent By dpalmer Date 2001-04-19 Time 21:09 Rev Time 0.00
Received By dpalmer Date 2001-04-19 Time 21:09 Sent To  
Notes
2001-04-19 00:00:00REV FOR BACK BATH AND RETREAT AREA ONLY,
 PLANS HAVE NOT BEEN RE-DRAWN YET.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-01-03 Cont ID  
Sent By dpalmer Date 2001-01-03 Time 18:58 Rev Time 0.00
Received By dpalmer Date 2001-01-03 Time 18:58 Sent To  
Notes
2001-01-08 00:00:00*************** REVISION NEEDED!! ******
  
  
 1)NOTE: PLANS ARE TO BE REVISED WITH
 ALL REDLINED ITEMS AND AS-BUILTS.
 PLANS ARE TO BE SUBMITTED AND REVIEWED
 BEFORE ANY FINAL ELECTRICAL INSPECTION
 IS CALLED IN.
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-11-28 Cont ID  
Sent By dpalmer Date 2000-11-28 Time 17:11 Rev Time 0.00
Received By dpalmer Date 2000-11-28 Time 17:11 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: ALL OUTLETS SERVING KITCHEN
 COUNTERSPACE ARE TO BE SHOWN AS GFI/GFI
 PROTECTED PER 210-8-A-6
  
 2)NOTE: PLEASE SEE MISSING GFI FOR POWD-
 -ER ROOM. PER 210-52D AND 210-11-C3
  
 3)NOTE: PLEASE SEE MISSING OUTLETS PER
 210-52 FOR 2` OF WALL SPACE.
  
 4)NOTE: SMOKE DETECTOR REQ`D INSIDE AND
 OUTSIDE ALL SLEEPING ROOMS OF NEW CONST-
 -RUCTION. NFPA-72 2-2.1.1.1
  
 5)NOTE: PLEASE NOTE AS PER 250-50 NEW
 BLDG STEEL AT NEW GARAGE TO BE BONDED.
 PLEASE SHOW WITH COLD WATER.
  
 6)NOTE: PLEASE NOTE THAT NOW A NEW SERV-
 -ICE IS BEING INSTALLED. PLEASE PROVIDE
 AIC RATINGS FOR ALL NEW EQUIPMENT BEING
 INSTALLED. MUST BE RATED FOR THE AVAIL-
 ABLE FAULT CURRENT PER 110-9.
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW.
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-07-16 Cont ID  
Sent By pkrauss Date 2001-07-16 Time 13:04 Rev Time 0.30
Received By pkrauss Date 2001-07-16 Time 12:48 Sent To  
Notes
2001-07-16 00:00:00MECH PERMIT 01010268

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-01-08 Cont ID  
Sent By jleech Date 2001-01-08 Time 15:23 Rev Time 0.33
Received By jleech Date 2001-01-08 Time 08:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-11-30 Cont ID  
Sent By jleech Date 2000-11-30 Time 16:35 Rev Time 0.25
Received By jleech Date 2000-11-30 Time 16:34 Sent To  
Notes
2001-01-08 00:00:00NO A/C DRAWINGS A/C DRAWINGS REQUIRED
 WITH A/C APPLICATION BY A/C CONTRACTOR.

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-07-16 Cont ID  
Sent By jleech Date 2001-07-16 Time 19:32 Rev Time 0.33
Received By jleech Date 2001-07-16 Time 19:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-04-26 Cont ID  
Sent By jleech Date 2001-04-26 Time 18:08 Rev Time 0.50
Received By jleech Date 2001-04-26 Time 18:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-11-30 Cont ID  
Sent By jleech Date 2000-11-30 Time 16:37 Rev Time 0.25
Received By jleech Date 2000-11-30 Time 16:37 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-01-08 Cont ID  
Sent By fknapp Date 2001-01-08 Time 11:29 Rev Time 4.00
Received By fknapp Date 2001-01-08 Time 09:49 Sent To  
Notes
2001-01-08 00:00:00 
  
 *************BUILDING PROVISO***********
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 MULLIONS
 ROOF COVERING UNDER SEPARATE PERMIT
  
 2)PROVIDE FLOOD ZONE ELEVATION
 CETIFICATE FOR NEW GARAGE WITH BFE OF
 7.5'
  
 3)PROVIDE SEPARATE PERMIT FOR NEW DRIVE.
  
 ANY QUESTIONS PLEASE CALL,
 FRANK KNAPP
 PLAN REVIEW
 CITY OF WEST PALM BEACH
 659-8096 EXT 8392

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-12-19 Cont ID  
Sent By fknapp Date 2000-12-19 Time 14:13 Rev Time 4.00
Received By fknapp Date 2000-12-19 Time 14:13 Sent To  
Notes
2001-01-08 00:00:00 
  
 *************BUILDING UNSAT*************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 ALL SH WINDOWS
 MULLIONS
 FRENCH DOORS WITH SIDELITES
 ALL EXTERIOR SWING DOORS
 GARAGE DOORS
 ROOF COVERING UNDER SEPARATE PERMIT
  
 2)PROVIDE STORM PANEL INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC
 MOUNTING AND ANCHORS TO BE USED.
  
 3)PROVIDE ENERGY CALCULATIONS
  
 4)PROVIDE 2 CURRENT SIGN AND SEALED
 SURVEYS WITH ALL IMPROVEMENTS TO BE MADE
 SHOWN ON SURVEY.
  
 5)PROVIDE 1 BATHROOM DOOR WITH 29" NET
 CLEAR OPENING ON HABITABLE GRADE LEVEL
 FACBC 4.22.2
  
 6)PROVIDE CEILING HEIGHT TO COMPLY WITH
 1997 SBC 1203.2 CLARIFY +- 7'BOT OF BEAM
 HABITABLE SPACES CEILING HEIGHT SHALL BE
 7'6"
  
 7)PROVIDE DETAILS OF NEW WALL CONNECTION
 TO EXISTING WALLS.
  
 8)PROVIDE ROOF SHEATHING NAILING ZONES
 THAT COMPLY WITH CITY AMENDMENTS FIG.
 2306.1 SBC 1606
  
 9)PROVIDE SPECIFIC WINDOW,EXTERIOR DOORS
 AND GARAGE DOORS BUCK CONNECTION DETAILS
 FOR WINDLOAD COMPLIANCE. SBC 1606
  
 10)PROVIDE A5 FLOOD ZONE ELEVATION
 CERTIFICATE WITH NEW CONSTRUCTION FLOOR
 ELEVATION OF 7.5'
  
 11)PROVIDE NOC RECORDED WITH CLERK OF
 COURT BEFORE BUILDING PERMIT CAN BE
 ISSUED.
  
 12)PROVIDE PAID IMPACT FEE RECEIPT.
  
 13)PROVIDE DRIVE UNDER SEPARATE PERMIT.
  
 ANY QUESTIONS PLEASE CALL
 FRANK KNAPP
 BUILDING PLAN REVIEW
 CITY OF WEST PALM BEACH
 659-8096 EXT 8392

Review Stop Z ZONING
Rev No 1 Status P Date 2000-12-19 Cont ID  
Sent By fknapp Date 2000-12-19 Time 14:12 Rev Time 0.00
Received By fknapp Date   Time   Sent To  
Notes
2001-01-08 00:00:00OK PER S.GRAHAM