Plan Review Details - Permit 00110647
| Plan Review Stops For Permit 00110647 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-05-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-05-03 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-05-03 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2001-05-03 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE THAT NOT ALL NOTES | | | FROM ORIG PROVISO WERE NOT ADDRESSED. | | | | | | PLEASE SEE NOTES ATTACHED FROM FIRST REV | | | IEW. #`S 4,6,8. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-11-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-15 |
Time |
18:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-15 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ********PLEASE REVISE ************** | | | | | | 1)NOTE: PLEASE SUBMIT PLANS WITH MORE | | | ELECTRICAL DETAIL SHOWN. | | | | | | 2)NOTE: PLEASE SHOW A/C UNITS. SHOW | | | DISCONNECTS PER 440-11 AND RECEPT PER | | | LOCAL MECH CODE. | | | | | | 3)NOTE: NO HWH SHOWN?? IS THIS CORRECT? | | | IF THERE IS ONE PLEASE SHOW ON PANEL | | | AND PLAN. INCLUDE ON LOAD CALCS. | | | | | | 4)NOTE: PLEASE NOTE THAT SD`S ARE REQ`D | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS | | | PER NFPA-72 2-2.1.1.1 | | | | | | 5)NOTE: PLEASE LABEL/SHOW ALL OUTLETS | | | THAT MEET THE REQ`MENTS FOR 210-8 AS | | | GFI/GFI PROTECTED. | | | | | | 6)NOTE:PLEASE INCLUDE BLDG STEEL AND CWP | | | AS PART OF THE GROUNDING BOND AT CABANA. | | | PER 250-50 | | | | | | 7)NOTE: PLEASE NOTE THAT IF THERE IS | | | GOING TO BE ANY LOW VOLTAGE IN THE | | | CABANA THEN PLEASE SHOW ON PLAN. THIS | | | MIGHT INCLUDE CATV,TELEPHONE,SPEAKERS | | | ETC. PLEASE NOTE SEPARATE LV PERMIT | | | IS REQ`D OR INCLUDE ON THIS PERMIT. | | | | | | 8)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | NEW EQUIPMENT BEING INSTALLED. MAINS | | | /PANELS MUST BE RATED FOR THE AVAILABLE | | | FAULT CURRENT. PER 110-9 | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW BEFORE ROUGH INSPECTION. | | | IF THERE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
|