| Plan Review Stops For Permit 00110363 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2001-03-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-03-27 |
Time |
19:09 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-01-25 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2001-01-25 |
Time |
14:17 |
Rev Time |
0.25 |
| Received By |
drunnels |
Date |
2001-01-25 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-12-22 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-12-22 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SAME AS PREVIOUS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-11-20 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-11-20 |
Time |
15:10 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-11-20 |
Time |
15:10 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1]SUBMIT PRODUCT APPROVALS FOR IMPACT | | | RESISTANT GLAZING FOR STOREFRONT | | | WINDOWS AND DOORS. METRO DADE COUNTY | | | OR SBCCI | | | 2]SUBMIT FIRE SPRINKLER PLANS AND PERMIT | | | APPLICATION. | | | 3]SUBMIT LETTER FROM SPECIAL INSPECTOR |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2001-01-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-03 |
Time |
21:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-03 |
Time |
21:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-30 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-30 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SUBMIT AND SHOW AIC RAT- | | | -INGS FOR MAIN DISCONNECT. PANEL SHOWS | | | AT 10,000 BUT STILL NEED THE RATING FOR | | | MAIN THAT MUST BE RATED PER 110-9. | | | | | | PLEASE SUBMIT THE ABOVE INFOMATION FOR | | | REVIEW. PLANS WOULD HAVE PASSED WITH | | | PROVISO, BUT WERE ONLY IN FOR PLAN | | | REVIEW AND WERE COMING BACK FOR OTHER | | | COMMMENTS.IF THERE ARE AN QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-11-08 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-08 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-08 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) PROVIDE SEPARATE PLAN AND PERMIT FOR | | | FIRE ALARM EQUIPMENT SHOWN ON PLANS. | | | PLANS ARE TO CONTAIN FLOOR PLANS, CUT | | | SHEETS AND WIRING DIAGRAM. | | | | | | PLANS REVIEWED BY CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-08 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-01-08 |
Time |
11:16 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2001-01-08 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-11-30 |
Time |
11:42 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-11-30 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | LOCATE AHU WITH RESPECT TO BUILDING | | | CONSTRUCTION TO ALLOW FOR SERVICE AND | | | REMOVAL OF EQUIPMENT AND COMPONENTS | | | MINIMUM CLEARANCE BETWEEN ROOF SURFACE | | | AND BOTTOM OF EQUIPMENT SUPPORT IS 18". |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2001-01-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-18 |
Time |
09:49 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-01-18 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-12-03 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-12-03 |
Time |
08:24 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEWDENIED | | | (1) SHT MP-1 H/C REST RM'S TO BE | | | ACCESSIBLE TO THE PUBLIC & SIGNAGE. | | | FACBC 4.1.3(1) (11) (16) (A) | | | (2) SHT MP-1 AIR CHAMBERS TO BE | | | ACCESSIBLE & RECHARGEABLE,SPC 94 | | | SEC 607.8.3 | | | END OF COMMENTS PAUL SCHMITZ | | | 561-659-8096 X 8233 |
|
|