| Plan Review Stops For Permit 00110160 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-11-22 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2000-11-22 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-02-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-15 |
Time |
06:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-15 |
Time |
06:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-12-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-11 |
Time |
19:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-11 |
Time |
19:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-21 |
Time |
20:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-21 |
Time |
20:25 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: AIC RATINGS ARE SUBMITTED FOR | | | PANELS BUT NOT FOR MAIN. PLEASE SUBMIT | | | AIC RATING FOR MAIN ALSO. NOTE; MAINS | | | MUST BE RATED FOR THE AVAIABLE FAULT | | | CURRENT PER 110-9 AND SHOW PER 215-5. | | | | | | 2)NOTE:PLEASE SHOW DETAIL FOR GROUND | | | ATTACHMENT AT 16KVA UPS. PLEASE CLARIFY | | | NOTE NEXT TO UPS AS (LCOCATION) 1ST FL.? | | | | | | | | | 3)NOTE: PLEASE SHOW LOCATION OF NEW 400A | | | DISC AND EXISTING SERVICE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2000-11-14 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-14 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-14 |
Time |
11:01 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) INTERIOR FINISH ON WALLS AND CEILINGS | | | TO BE AT LEAST CLASS C. | | | 2) BUILDING ADDRESS IS REQUIRED PER CITY | | | CODE REQUIREMENTS. | | | | | | PLANS REVIEWED BY CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2001-02-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-02-21 |
Time |
08:25 |
Rev Time |
0.33 |
| Received By |
pkrauss |
Date |
2001-02-21 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2001-02-21 00:00:00 | DUCT SMOKE DETECTOR IS NOT REFLECTED ON | | | DWG. M2.1 BUT IS INSTALLED AND HAS BEEN | | | TESTED (AHU-6) AS PER NANCY. | | | | | | PHK 2/21/01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-02-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-02-16 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2001-02-16 |
Time |
15:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-30 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-01-30 |
Time |
15:00 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-01-30 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2001-01-30 00:00:00 | REVISION DATED 1-05-01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-11-30 |
Time |
13:41 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-11-30 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2000-12-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-20 |
Time |
15:08 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2000-12-20 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | STILL NEEDS WATER HEATER REVISION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-13 |
Time |
13:34 |
Rev Time |
1.25 |
| Received By |
jleech |
Date |
2000-12-13 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO; | | | | | | REVISED DRAWINGS REQUIRED TO MEET | | | FACBC AND SPC CODES TO THE | | | FOLLOWING ITEMS. | | | | | | 1.WATER HEATER; 501.7, STATES READILY | | | ACCESSIBLE. REFER TO CHAPTER 2 | | | DEFINITIONS. ( READILY ACCESSIBLE) | | | HAVING ACCESS WITHOUT THE NEED OF, | | | A PORTABLE LADDER. | | | | | | 2.[ A-9.2 LOUNGE 116 AND PRINTROOM 119 | | | DONOT SHOW COMPLIANCE TO 4.24 THRU | | | 4.24.7. | | | | | | 3.DRINKING FOUNTAIN, PAGE A-9.1 AND | | | A-2.1 DONOT SHOW COMPLIANCE TO | | | RESPONSE TO NOTE 3 BY ROGER HANSROTE | | | ARCHITECT ON DEC. 7TH 2000. | | | | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-11-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-16 |
Time |
16:45 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2000-11-16 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.WATER HEATER MUST BE LOCATED ON FLOOR | | | OR A FIXED LADDER MUST BE INSTALLED | | | READLY ACCESSIBLE SPC 501.7 | | | 2.P-3.1 [DOMESTIC WATER PLAN] NO WATER | | | TO UR. OR SK. | | | 3.DRINKING FOUNTAIN TO BE HIGH-LOW | | | COMBO FOR PEOPLE WHO CANNOT BEND OR | | | STOUP, OR INSTALL A CUP DISPENSOR. | | | 4.ONE KS. MUST COMPLY WITH 97-SACBC | | | SEC.4.24. | | | 5.SHOW DIMENSIONS FOR H.C. STALLS. SHOW | | | 5' TURNING CIRCLE. |
|
|