Plan Review Details - Permit 00110096
| Plan Review Stops For Permit 00110096 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2001-02-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-02-27 |
Time |
19:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-02-27 |
Time |
19:51 |
Sent To |
|
|
| Notes |
| 2001-02-27 00:00:00 | ****************** UNSAT ************** | | | | | | 1)NOTE: PLEASE SUBMIT CLARIFICATION | | | ON NOTE #1 OF FIRST REVIEWS. IS ALL | | | ELECTRICAL EQUIPMENT RATED AT 22,000 AIC | | | ? NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW EQUIPMENT BEING INSTALLED. | | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | | | 2)NOTE: PLEASE SEE NOTE#6 FROM FIRST | | | REVIEWS, ONLT ONE DISCONNECT IS SHOWN. | | | | | | 3)NOTE: PLEASE SHOW CLARIFICATION ON | | | EQUIPMENT GROUNDING CONDUCTOR FROM MAIN | | | TO PANELS. SIZE PER 250-122. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-01-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-17 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-17 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2001-01-17 00:00:00 | ***************** UNSAT **************** | | | | | | 1)NOTE: PLEASE NOTE, UNDER F.A.C. ALL | | | CHANGES ON PLANS ARE TO BE SIGNED AND | | | DATED AT EACH CHANGE BY THE ARCH/ENG OF | | | RECORD. 471.025/ 481.221 PLEASE EITHER | | | REDO PLANS OR INITAL AND DATE EACH | | | CHANGE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 | | | | | | | | | 2)NOTE: ALSO PLEASE NOTE THAT THE RISER | | | SHOWS 6-4/0`S. PLEASE SEE TABLE | | | 310-15-B-6. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-30 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-30 |
Time |
18:47 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT ***************** | | | | | | 1)NOTE: PLEASE SEE AIC RATING SHOWN NEXT | | | TO MLO PANEL. IS THIS THE AIC RATING FOR | | | THE MAIN DISC ALSO? ALSO PLEASE NOTE | | | IF SO, THEN ALL BREAKERS IN THE 8-16 | | | PANEL ARE TO BE RATED FOR 22,00 ALSO | | | OR SHOW SERIES RATING FOR THESE. | | | | | | 2)NOTE: PLEASE SEE WIRE SIZE SHOWN FOR | | | 250A FEED FROM MAIN TO SUB-PANEL WITH | | | 1/0 AWG SHOWN. PLEASE CORRECT PER 310-16 | | | | | | 3)NOTE: PLEASE SHOW WP GFI OUTLET FOR\\ | | | A/C COND UNIT PER SEC 309.1 OF THE | | | MECH CODE. | | | | | | 4)NOTE: PLEASE SEE MISSING GFI OUTLET | | | FOR CABANA BATH PER 210-52D AND 210-11- | | | C-3. PLEASE SHOW. | | | | | | 5)NOTE: PLEASE SEE GARAGE, AHU`S SHOWN | | | IN ATTIC. PLEASE PROVIDE OUTLET PER | | | 210-63 OF THE NEC AND 309.1 | | | | | | 6)NOTE: PLEASE SHOW MAIN DISCONNECT ON | | | PLAN NEXT TO METER AS SHOWN ON RISER | | | DIAGRAM. | | | | | | 7)NOTE: PLEASE NOTE THE MISSING SMOKE | | | DETECTOR PER NFPA-72 2-2.1.1.1 IN BED- | | | -ROOM #4. | | | | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-30 |
Time |
18:05 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-11-30 |
Time |
18:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-30 |
Time |
18:05 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-11-30 |
Time |
18:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2001-02-20 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2001-02-20 |
Time |
14:49 |
Rev Time |
2.00 |
| Received By |
fknapp |
Date |
2001-02-20 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2001-02-20 00:00:00 | | | | | | | ***************TRUSSES UNSAT************ | | | | | | SBC 104.2.2 | | | | | | 1) PROVIDE CONNECTORS THAT SUPPLY | | | ADEQUATE UPLIFT FOR THE FOLLOWING | | | TRUSSES: | | | GT-1 | | | GT-3 | | | GT-5 | | | GT-6 | | | | | | PLEASE REVIEW ALL CONNECTIONS FOR | | | ADEQUATE UPLIFT. | | | | | | ANY QUESTIONS PLEASE CALL, | | | FRANK KNAPP | | | BUILDING PLAN REVIEW | | | DEPARTMENT OF CONSTRUCTION SERVICES | | | CITY OF WEST PALM BEACH | | | (561) 659-8096 EXT. 8392 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-12-08 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-12-08 |
Time |
08:27 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ***********BUILDING UNSAT*************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR ALL EXTERIOR SWING DOORS TO BE USED | | | WITH APPROVED DRAWINGS. | | | | | | 2)PROVIDE SAFETY GLASS AS REQ PER 1997 | | | SBC 2405.2.1(3) | | | | | | 3)PROVIDE ROOF FRAMING PLAN WITH UPLIFT | | | CALCULATIONS WITH SPECIFIC CONNECTORS | | | TO BE USED. | | | | | | 4)PROVIDE TRUSS ENGINEERING SHEETS AND | | | LAYOUT PLAN. | | | | | | 5)PROVIDE ENGINEERING FOR ALL BUTT GLASS | | | OPENINGS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | MODEL ONLY |
|
|
|