| Plan Review Stops For Permit 00110047 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-05-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-05-24 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-24 00:00:00 | OK FOR DOOR SWING PER JIM WITMER. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-05-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-05-11 |
Time |
13:20 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-05-11 00:00:00 | CALLED ARCH OK TO CHANGE SWING OF DOOR | | | TO RESTROOM FOR HANDICAPPED EGRESS | | | 05/11/01 JW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-11-03 |
|
|
Cont ID |
|
| Sent By |
bstaples |
Date |
2000-11-03 |
Time |
15:25 |
Rev Time |
1.00 |
| Received By |
bstaples |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. NO MECHANICIAL PLAN SUBMITTED | | | SEPERATE PALNS AND PWRMIT REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2001-05-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-05-24 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-05-24 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2001-05-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-05-09 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-05-09 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2001-05-09 00:00:00 | ****************** UNSAT************** | | | | | | | | | 1)NOTE: PLEASE NOTE THAT ORIG PROVISO | | | NEEDS TO BE ADDRESSED. IF THERE ARE | | | ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-04-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-04-19 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-04-19 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2001-04-19 00:00:00 | PROVISO FROM FIRST SET OF NOTES STILL | | | STAND. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2001-01-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-01-17 |
Time |
21:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-01-17 |
Time |
21:00 |
Sent To |
|
|
| Notes |
| 2001-01-17 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLANS NEED TO HAVE ALL BRANCH | | | CIRCUIT #`S SHOWN ON PLANS AND | | | CORRELATE WITH PANEL SCHEDULE TO BE | | | SUBMITTED. | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS PLEAS | | | E CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-21 |
Time |
17:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-21 |
Time |
17:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2001-05-03 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2001-05-03 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2001-05-03 |
Time |
08:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-01-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-22 |
Time |
14:31 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2001-01-22 |
Time |
14:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-11-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-27 |
Time |
07:30 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-11-27 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-11-03 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-11-03 |
Time |
06:53 |
Rev Time |
1.25 |
| Received By |
tlarge |
Date |
2000-11-02 |
Time |
19:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)DESIGN OF SANITARY SYSTEM SHALL COMPLY | | | W/SPC SECS.: | | | A)906.2.1-DRY VENTS NOT PERMITTED.BASE | | | OF STACK SHALL BE WASHED BY A FIXTURE. | | | B)FIXTURE BRANCHES NOT PERMITTED ON WET | | | VENT.COUNTYWIDE AMENDMENTS TO SPC SEC. | | | 911.1.1. | | | C)FLOOR DRAIN W/TRAP PRIMER REQD.IN | | | TOILET ROOM PER SPC SEC.409.4.1.1. | | | D)SUBMIT SQUARE FEET OF HABITABLE FLOOR | | | SPACE AND OCCUPANT LOAD PER SPC TABLE | | | 407.SEE SEC.407.1.3 FOR ALLOWED DEDUCT- | | | IBLE AREAS.SUBMIT CALCULATIONS. | | | E)GRAB BARS BEHIND AND ALONGSIDE TOILET | | | SHALL COMPLY W/FACBC SEC.4.16.4. | | | F)FIXTURES SHALL BE PROPERLY VENTED.SPC | | | SEC.901.2. | | | G)SUBMIT WATER RISER DIAGRAM FOR REVIEW. | | | COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1 | | | | | | CALL IF YOU HAVE ANY QUESTIONS. | | | 561-659-8096,EXT.8377. | | | | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|