Plan Review Details - Permit 00110047
Plan Review Stops For Permit 00110047
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2001-05-24 Cont ID  
Sent By dpalmer Date 2001-05-24 Time 09:48 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2001-05-24 00:00:00OK FOR DOOR SWING PER JIM WITMER.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-05-11 Cont ID  
Sent By jwitmer Date 2001-05-11 Time 13:20 Rev Time 1.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-05-11 00:00:00CALLED ARCH OK TO CHANGE SWING OF DOOR
 TO RESTROOM FOR HANDICAPPED EGRESS
 05/11/01 JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-11-03 Cont ID  
Sent By bstaples Date 2000-11-03 Time 15:25 Rev Time 1.00
Received By bstaples Date   Time   Sent To  
Notes
2001-01-08 00:00:001. NO MECHANICIAL PLAN SUBMITTED
 SEPERATE PALNS AND PWRMIT REQUIRED.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2001-05-24 Cont ID  
Sent By dpalmer Date 2001-05-24 Time 09:47 Rev Time 0.00
Received By dpalmer Date 2001-05-24 Time 09:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2001-05-09 Cont ID  
Sent By dpalmer Date 2001-05-09 Time 14:12 Rev Time 0.00
Received By dpalmer Date 2001-05-09 Time 14:12 Sent To  
Notes
2001-05-09 00:00:00****************** UNSAT**************
  
  
 1)NOTE: PLEASE NOTE THAT ORIG PROVISO
 NEEDS TO BE ADDRESSED. IF THERE ARE
 ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 8372

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-04-19 Cont ID  
Sent By dpalmer Date 2001-04-19 Time 14:46 Rev Time 0.00
Received By dpalmer Date 2001-04-19 Time 14:46 Sent To  
Notes
2001-04-19 00:00:00PROVISO FROM FIRST SET OF NOTES STILL
 STAND.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2001-01-17 Cont ID  
Sent By dpalmer Date 2001-01-17 Time 21:01 Rev Time 0.00
Received By dpalmer Date 2001-01-17 Time 21:00 Sent To  
Notes
2001-01-17 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLANS NEED TO HAVE ALL BRANCH
 CIRCUIT #`S SHOWN ON PLANS AND
 CORRELATE WITH PANEL SCHEDULE TO BE
 SUBMITTED.
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS PLEAS
 E CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-11-21 Cont ID  
Sent By dpalmer Date 2000-11-21 Time 17:26 Rev Time 0.00
Received By dpalmer Date 2000-11-21 Time 17:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2001-05-03 Cont ID  
Sent By mcarsill Date 2001-05-03 Time 08:51 Rev Time 0.00
Received By mcarsill Date 2001-05-03 Time 08:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-01-22 Cont ID  
Sent By jleech Date 2001-01-22 Time 14:31 Rev Time 0.50
Received By jleech Date 2001-01-22 Time 14:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-11-27 Cont ID  
Sent By jleech Date 2000-11-27 Time 07:30 Rev Time 0.33
Received By jleech Date 2000-11-27 Time 07:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-11-03 Cont ID  
Sent By tlarge Date 2000-11-03 Time 06:53 Rev Time 1.25
Received By tlarge Date 2000-11-02 Time 19:40 Sent To  
Notes
2001-01-08 00:00:001)DESIGN OF SANITARY SYSTEM SHALL COMPLY
 W/SPC SECS.:
 A)906.2.1-DRY VENTS NOT PERMITTED.BASE
 OF STACK SHALL BE WASHED BY A FIXTURE.
 B)FIXTURE BRANCHES NOT PERMITTED ON WET
 VENT.COUNTYWIDE AMENDMENTS TO SPC SEC.
 911.1.1.
 C)FLOOR DRAIN W/TRAP PRIMER REQD.IN
 TOILET ROOM PER SPC SEC.409.4.1.1.
 D)SUBMIT SQUARE FEET OF HABITABLE FLOOR
 SPACE AND OCCUPANT LOAD PER SPC TABLE
 407.SEE SEC.407.1.3 FOR ALLOWED DEDUCT-
 IBLE AREAS.SUBMIT CALCULATIONS.
 E)GRAB BARS BEHIND AND ALONGSIDE TOILET
 SHALL COMPLY W/FACBC SEC.4.16.4.
 F)FIXTURES SHALL BE PROPERLY VENTED.SPC
 SEC.901.2.
 G)SUBMIT WATER RISER DIAGRAM FOR REVIEW.
 COUNTYWIDE AMENDMENTS TO SPC SEC.104.2.1
  
 CALL IF YOU HAVE ANY QUESTIONS.
 561-659-8096,EXT.8377.
  
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.