Plan Review Details - Permit 00110030
Plan Review Stops For Permit 00110030
Review Stop E ELECTRICAL
Rev No 3 Status P Date 2001-06-01 Cont ID  
Sent By jleahy Date 2001-06-01 Time 09:22 Rev Time 1.00
Received By jleahy Date 2001-06-01 Time 09:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-12-26 Cont ID  
Sent By dpalmer Date 2000-12-26 Time 11:54 Rev Time 0.00
Received By dpalmer Date 2000-12-26 Time 11:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-11-20 Cont ID  
Sent By dpalmer Date 2000-11-20 Time 21:07 Rev Time 0.00
Received By dpalmer Date 2000-11-20 Time 21:07 Sent To  
Notes
2001-01-08 00:00:00************** UNSAT ******************
  
 1)NOTE: PLEASE NOTE THAT A MCB IS REQ`D
 AT MAIN HOUSE."PANEL A"
  
 2)NOTE: PLEASE NOTE THAT NEW BLDG STEEL
 AT MAIN HOUSE TO BE BONDED ALONG WITH
 COLD WATER PER 250-50 PLEASE SHOW.
  
 3)NOTE: PLEASE SHOW SMOKE DETECTORS AS
 REQ`D BY NFPA-72 2-2.1.1.1 INSIDE AND
 OUTSIDE NEW BEDROOM.
  
 4)NOTE: PLEASE NOTE THAT THE REQ`D DEDI-
 -CATED BATH CIRCUIT IS NOT LISTED ON
 PANEL SCHEDULE. PLEASE SHOW, #12,20AMP.
  
 5)NOTE: MISSING OUTLET FOR KITCHEN
 PENINSULAR PER 210-52-C-3.
 ALL OUTLETS ERVING KITCHEN COUNTERSPACE
 ARE TO GFI/GFI PROTECTED PER 210-8-A-6
 PLEASE SHOW.
  
 6)NOTE: PLEASE NOTE MISSING OUTLET FOR
 A/C COND UNITS AT GUESTHOUSE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2001-01-05 Cont ID  
Sent By jleech Date 2001-01-05 Time 10:30 Rev Time 0.25
Received By jleech Date 2001-01-05 Time 10:30 Sent To  
Notes
2001-01-08 00:00:00A/C PLAN BY A/C CONTRACTOR.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2001-01-02 Cont ID  
Sent By jleech Date 2001-01-02 Time 18:39 Rev Time 0.50
Received By jleech Date 2001-01-02 Time 18:39 Sent To  
Notes
2001-01-08 00:00:00DENIED;
 1.PAGES FROM STEPHEN K. DENNY ARE NOT
 SEALED.
  
 2.IS WATER HEATER POWER VENTED AS SHOWN
 ON PAGE M-1 OR AS SHOWN ON A/C CONT.
 CUT SHEET? IF POWER VENTED SUBMIT
 MANUFACTORS SPECIFICATIONS. IF W/H
 IS CONVENTIONAL MAKE UP AIR IS NOT
 TO CODE. SEE SMC FIGURE 402.4A,B,C&D.
  
 3.NEED SEER AND HEAT STRIP SIZE FOR
 PACKAGE UNIT.
  
 4.DRAIN SPOUT TO DRAIN TO GRASSY AREA.
  
 A/C PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT.8377

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-11-21 Cont ID  
Sent By jleech Date 2000-11-21 Time 19:17 Rev Time 0.50
Received By jleech Date 2000-11-21 Time 19:16 Sent To  
Notes
2001-01-08 00:00:00DENIED;
 1.NEED WATER HEATER MANUFACTURE'S
 SPECIFICATIONSFOR VENTING AND MAKE UP
 AIR.
 2.SUBMIT A/C EQUIPMENT SPECIFICATIONS
 ON NEW ROOF TOP UNIT;
 1.MANUFACTURE
 2.MODEL NUMBER
 3.SEER VALUE
 4.HEAT STRIP SIZE
 3.NEED DIAGRAM SHOWING HOW PACKAGE
 UNIT IS STRAPED TO ROOF TO MEET 110
 MPR WINDS.
 4.SHOW HOW CONDENSATE RUN OFF WILL BE
 DISPOSED.

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-11-21 Cont ID  
Sent By jleech Date 2000-11-21 Time 19:35 Rev Time 0.33
Received By jleech Date 2000-11-21 Time 19:35 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-01-03 Cont ID  
Sent By rmcdouga Date 2001-01-03 Time 11:42 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-11-30 Cont ID  
Sent By drunnels Date 2000-11-30 Time 09:18 Rev Time 4.00
Received By rmcdouga Date 2000-11-30 Time 14:29 Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)IMPACT FEES MUST BE PAID TO P.B.COUNTY
 PLANS STAMPED BY THEM AND COPY OF
 RECEIPT SUBMITTED TO CITY OF W.P.B.
 BUILDING DEPARTMENT BEFORE PERMIT CAN BE
 ISSUED.
  
 2)ENERGY EFFICIENCY CODE FORMS MUST BE
 SIGNED BY OWNER OR AGENT.
  
 3)PROVIDE 2 COMPLETED DESIGN COMPLIANCE
 FORMS WITH WET SIGNATURE, DATE AND
 IMPRESSION SEAL OF DESIGNER OF RECORD.
  
 4)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR CASEMENT
 AND DOUBLEHUNG WINDOWS THAT ARE BEING
 RELOCATED AND FOR NEW FRONT DOOR.
 SITE SPECIFIC ENGINEERING IS ACCEPTABLE.
  
 5)PROVIDE 2 CURRENT COPIES OF METRO-DADE
 OR SBCCI PRODUCT APPROVALS FOR ROOF
 COVERING UNDER SEPARATE PERMIT.
  
 6)PROVIDE ADDITIONAL COPIES OF SOIL TEST
 AND PRODUCT APPROVALS FOR FRENCH DOORS &
 MULLIONS. ONLY ONE COPY OF EACH WERE
 RECEIVED.
  
 7)PROVIDE STRUCTURAL DETAILS AND FIRE
 RESISTANCE OF AWNING MATERIAL UNDER
 SEPARATE PERMIT.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-11-13 Cont ID  
Sent By sgraham Date 2000-11-13 Time 08:18 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***