Plan Review Details - Permit 00101433
Plan Review Stops For Permit 00101433
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2001-01-30 Cont ID  
Sent By jwitmer Date 2001-01-30 Time 16:21 Rev Time 1.25
Received By jwitmer Date   Time   Sent To  
Notes
2001-01-30 00:00:00PROVISO: PROVIDE A SECOND COPY OF
 PRODUCT APPROVAL BEFORE ISSUANCE. JW

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2001-01-03 Cont ID  
Sent By jwitmer Date 2001-01-03 Time 16:45 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2001-01-30 Cont ID  
Sent By dpalmer Date 2001-01-30 Time 17:08 Rev Time 0.00
Received By dpalmer Date 2001-01-30 Time 17:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2001-01-03 Cont ID  
Sent By dpalmer Date 2001-01-03 Time 15:24 Rev Time 0.00
Received By dpalmer Date 2001-01-03 Time 15:24 Sent To  
Notes
2001-01-08 00:00:00***************** UNSAT ***************
  
 1)NOTE: ALL ELECTRICAL SHEETS NEED TO
 REFERENCE HC-1 FOR F.H.A REQ`MENTS.
  
 2)NOTE: PLEASE CORRELATE LOADS AND WIRE
 SIZES ON PANEL SCHEDULES TO MEET 310-16.
  
 3)NOTE: PLEASE SEE LOAD SHOWN FOR OVEN
 AT 12KW AND BRKR AT 50A? PLEASE CORRECT
  
 4)NOTE: PLEASE NOTE THAT OUTLETS SHOWN
 IN GARAGES ARE TO BE GFI/GFI PROTECTED.
 210-8
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096-EXT 8372

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2000-12-28 Cont ID  
Sent By mcarsill Date 2000-12-28 Time 11:01 Rev Time 0.00
Received By mcarsill Date 2000-12-28 Time 11:01 Sent To  
Notes
2001-01-08 00:00:001) BUILDING ADDRESS REQUIRED FOR FIRE
 AND PARAMEDICAL RESPONSE.
 2) WET FIRE HYDRANTS ARE TO BE PRESENT
 PRIOR, DURING AND AFTER CONSTRUCTION.
  
 CAPTAIN MIKE CARSILLO
 659-8096,EXT.8497
 835-2910

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-06-27 Cont ID  
Sent By pkrauss Date 2001-06-27 Time 11:05 Rev Time 0.30
Received By pkrauss Date 2001-06-27 Time 11:05 Sent To  
Notes
2001-06-27 00:00:00MECHANICAL PERMIT 00101535

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2001-01-03 Cont ID  
Sent By jleech Date 2001-01-03 Time 16:51 Rev Time 0.25
Received By jleech Date 2001-01-03 Time 16:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-05-08 Cont ID  
Sent By kstevens Date 2001-05-08 Time 14:30 Rev Time 0.25
Received By kstevens Date 2001-05-08 Time 14:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2001-01-03 Cont ID  
Sent By jleech Date 2001-01-03 Time 16:51 Rev Time 0.25
Received By jleech Date 2001-01-03 Time 16:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2001-01-31 Cont ID  
Sent By jwitmer Date 2001-01-31 Time 10:35 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2001-01-31 00:00:00APPROVED PER S. GRAHAM