| Plan Review Stops For Permit 00101333 |
| Review Stop |
|
|
| Rev No |
1 |
Status |
P |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-13 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-12-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-08 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-08 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-11-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-22 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-22 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | **************** UNSAT **************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW MAINS/PANELS BEING INSTALLED. | | | THE RISER IS SHOWING AN ALL NEW SERVICE. | | | | | | 2)NOTE: PLEASE SHOW GROINDING ELECTRODE | | | SYSTEM FOR GROUND ROD AND COLD WATER | | | BOND. | | | | | | 3)NOTE: MISSING GFI OULETS FRONTAND REAR | | | OF DWELLING PER 210-52E | | | | | | 4)NOTE: MISSING OUTLET FOR GARAGE PER | | | 210-52G | | | | | | 5)NOTE: PLEASE SHOW ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | | -ED PER 21O-8-A-6. | | | | | | 6)NOTE: PLEASE SHOW ON PANEL SCHEDULE | | | THE REQ`D DEDICATED BATH(S) CIRCUIT(S) | | | PER 210-11-C-3 #12/20A | | | | | | PLANS WOULD HAVE PASSED WITH A REVISION | | | REQ`ST/PROVISO BUT WERE COMING BACK FOR | | | PLUMB AND MECH CORRECTIONS. | | | PLEASE SUBMIT THE ABOVE INFOMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2000-12-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-13 |
Time |
11:00 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-12-13 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2000-12-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-01 |
Time |
08:40 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-12-01 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SIZE ALL DUCTS AND LIST CFM'S FOR EACH | | | DROP. | | | | | | A/C PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT. 8377 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-11-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-22 |
Time |
13:25 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-11-22 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO A/C PLAN; | | | SUBMIT PLAN SHOWING EXISTING SYSTEM AND | | | CHANGES TO BE MADE. INCLUDE EQUIPMENT | | | SIZE,MANUFACTOR,HEAT STRIP SIZE AND DUCT | | | SIZES AND DUCT MATERIAL. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-12-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-01 |
Time |
09:02 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-12-01 |
Time |
09:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-11-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-22 |
Time |
13:39 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2000-11-22 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED | | | 1.NOT ENOUGH INFOREMATION. LIST PLUMBING | | | WORK TO BE DONE. | | | 2.BACKFLOW PREVENTER REQUIRED ON WATER | | | SERVICE. CITY WATER DEPARTMENT | | | ORDINANCE. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2000-11-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2000-11-22 |
Time |
07:28 |
Rev Time |
2.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************PROVISO****************** | | | | | | 1)PROVIDE PRODUCT APPROVALS,KEY PLAN AND | | | INSTALLATION SCHEDULE INDICATING TYPE OF | | | FASTENERS BEING USED ON A SEPARATE | | | PERMIT. | | | | | | 2)SEPARATE PERMITS ARE REQUIRED FOR | | | DRIVEWAY AND FENCE. | | | | | | 3)IF ANY BEARING WALLS ARE BEING REMOVED | | | SHORING AND ENGINEERING IS REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-11-13 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2000-11-13 |
Time |
08:24 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ZONING APPROVAL FOR NEW TERRACE ONLY |
|
|