Plan Review Details - Permit 00101333
Plan Review Stops For Permit 00101333
Review Stop    
Rev No 1 Status P Date 2000-12-13 Cont ID  
Sent By jleech Date 2000-12-13 Time 11:00 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-12-08 Cont ID  
Sent By dpalmer Date 2000-12-08 Time 15:10 Rev Time 0.00
Received By dpalmer Date 2000-12-08 Time 15:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-11-22 Cont ID  
Sent By dpalmer Date 2000-11-22 Time 11:33 Rev Time 0.00
Received By dpalmer Date 2000-11-22 Time 11:33 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ****************
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW MAINS/PANELS BEING INSTALLED.
 THE RISER IS SHOWING AN ALL NEW SERVICE.
  
 2)NOTE: PLEASE SHOW GROINDING ELECTRODE
 SYSTEM FOR GROUND ROD AND COLD WATER
 BOND.
  
 3)NOTE: MISSING GFI OULETS FRONTAND REAR
 OF DWELLING PER 210-52E
  
 4)NOTE: MISSING OUTLET FOR GARAGE PER
 210-52G
  
 5)NOTE: PLEASE SHOW ALL OUTLETS SERVING
 KITCHEN COUNTERSPACE AS GFI/GFI PROTECT-
 -ED PER 21O-8-A-6.
  
 6)NOTE: PLEASE SHOW ON PANEL SCHEDULE
 THE REQ`D DEDICATED BATH(S) CIRCUIT(S)
 PER 210-11-C-3 #12/20A
  
 PLANS WOULD HAVE PASSED WITH A REVISION
 REQ`ST/PROVISO BUT WERE COMING BACK FOR
 PLUMB AND MECH CORRECTIONS.
 PLEASE SUBMIT THE ABOVE INFOMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2000-12-13 Cont ID  
Sent By jleech Date 2000-12-13 Time 11:00 Rev Time 0.25
Received By jleech Date 2000-12-13 Time 11:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2000-12-01 Cont ID  
Sent By jleech Date 2000-12-01 Time 08:40 Rev Time 0.25
Received By jleech Date 2000-12-01 Time 08:40 Sent To  
Notes
2001-01-08 00:00:00SIZE ALL DUCTS AND LIST CFM'S FOR EACH
 DROP.
  
 A/C PLAN REVIEW BY;
 JOHN LEECH
 659-8096 EXT. 8377

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2000-11-22 Cont ID  
Sent By jleech Date 2000-11-22 Time 13:25 Rev Time 0.25
Received By jleech Date 2000-11-22 Time 13:25 Sent To  
Notes
2001-01-08 00:00:00NO A/C PLAN;
 SUBMIT PLAN SHOWING EXISTING SYSTEM AND
 CHANGES TO BE MADE. INCLUDE EQUIPMENT
 SIZE,MANUFACTOR,HEAT STRIP SIZE AND DUCT
 SIZES AND DUCT MATERIAL.

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-12-01 Cont ID  
Sent By jleech Date 2000-12-01 Time 09:02 Rev Time 0.25
Received By jleech Date 2000-12-01 Time 09:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-11-22 Cont ID  
Sent By jleech Date 2000-11-22 Time 13:39 Rev Time 0.33
Received By jleech Date 2000-11-22 Time 13:39 Sent To  
Notes
2001-01-08 00:00:00DENIED
 1.NOT ENOUGH INFOREMATION. LIST PLUMBING
 WORK TO BE DONE.
 2.BACKFLOW PREVENTER REQUIRED ON WATER
 SERVICE. CITY WATER DEPARTMENT
 ORDINANCE.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2000-11-22 Cont ID  
Sent By rmcdouga Date 2000-11-22 Time 07:28 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00***************PROVISO******************
  
 1)PROVIDE PRODUCT APPROVALS,KEY PLAN AND
 INSTALLATION SCHEDULE INDICATING TYPE OF
 FASTENERS BEING USED ON A SEPARATE
 PERMIT.
  
 2)SEPARATE PERMITS ARE REQUIRED FOR
 DRIVEWAY AND FENCE.
  
 3)IF ANY BEARING WALLS ARE BEING REMOVED
 SHORING AND ENGINEERING IS REQUIRED.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-11-13 Cont ID  
Sent By sgraham Date 2000-11-13 Time 08:24 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
2001-01-08 00:00:00ZONING APPROVAL FOR NEW TERRACE ONLY