Plan Review Details - Permit 00101300
Plan Review Stops For Permit 00101300
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-10-01 Cont ID  
Sent By dpalmer Date 2001-10-01 Time 11:27 Rev Time 0.00
Received By dpalmer Date 2001-10-01 Time 07:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-12-21 Cont ID  
Sent By dpalmer Date 2000-12-21 Time 13:34 Rev Time 0.00
Received By dpalmer Date 2000-12-21 Time 13:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-12-19 Cont ID  
Sent By dpalmer Date 2000-12-19 Time 15:03 Rev Time 0.00
Received By dpalmer Date 2000-12-19 Time 15:03 Sent To  
Notes
2001-01-08 00:00:00****************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT UNDER F.A.C
 PLANS THAT ARE SIGNED AND SEALED NEED TO
 HAVE ALL CHANGES DONE BY THE ARC/
 ENGINEER OF RECORD. CHAPTER 471/481
 PLANS NEED TO BE RE-DRAWN WITH CHANGES.
  
 PLEASE SUBMIT THE ABOVE INFORMATIONFOR
 REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
  
 659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-11-07 Cont ID  
Sent By dpalmer Date 2000-11-07 Time 17:31 Rev Time 0.00
Received By dpalmer Date 2000-11-07 Time 17:31 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT ******************
  
 1)NOTE: PLEASESUBMIT AIC RATINGS FOR
 MAIN DISCONNECT AND PANEL. ALL MUST BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110-9. AND 215-5
  
 2)NOTE: SMOKE DETECTORS ARE REQ`D INSIDE
 AND OUTSIDE ALL SLEEPING ROOMS. PER
 NFPA-72 2-2.1.1.1
  
 3)NOTE: PLEASE SEE RISER DIAGRAM. YOU
 SHOW 1/0 CONDUCTORS FOR A 200A SERVICE.
 PLEASE SEE 310-15 AND 310-16 OF NEC.
  
 4)NOTE: PLEASE HAVE BLDG STEEL AS PART
 OF THE GROUNDING ELECTRODE CONDUCTOR
 PER 250-50. PLEASE SHOW.
  
 5)NOTE:PLEASE NOTE THAT OUTLET FOR
 GARAGE ARE TO BE GFI/GFI PROTECTED PER
 210-8. PLEASE SHOW.
  
 6)NOTE: ALL OUTLETS SERVING KITCHEN
 COUNTERSPACE ARE TO BE GFI/GFI PROTECTED
 PER 210-8-A-6.PLEASE SHOW
  
 7)NOTE: PLEASE INCLUDE MAIN DISCONNECT
 ON PLAN. NOT SHOWN WITH METER.
  
 8)NOTE: MISSING WP GFI FOR A/C UNITS
 ON SIDE OF HOUSE.
  
 9)NOTE:PLEASE LIST THE REQ`D BATH(S)
 CIRCUIT(S) ON PANEL SCHEDULE PER
 210-11-C-3. #12 AND 20A
  
 10)NOTE: PLEASE SEE 210-52 FOR OUTLET
 SPACING ALONG WALL SPACE 2`6`12` RULE.
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL
  
 DEWEY PALMER
 ELECTRCIAL PLAN REVIEW
 659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2001-10-15 Cont ID  
Sent By pkrauss Date 2001-10-15 Time 08:38 Rev Time 0.25
Received By pkrauss Date   Time   Sent To  
Notes
2001-10-15 00:00:00RE-STAMP FOR MECHANICAL

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2001-06-07 Cont ID  
Sent By pkrauss Date 2001-06-07 Time 13:49 Rev Time 0.30
Received By pkrauss Date 2001-06-07 Time 13:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-04-23 Cont ID  
Sent By pkrauss Date 2001-04-23 Time 15:43 Rev Time 0.30
Received By pkrauss Date 2001-04-23 Time 15:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-11-04 Cont ID  
Sent By jleech Date 2000-11-04 Time 12:16 Rev Time 0.50
Received By jleech Date 2000-11-04 Time 12:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-11-04 Cont ID  
Sent By jleech Date 2000-11-04 Time 12:21 Rev Time 0.33
Received By jleech Date 2000-11-04 Time 12:21 Sent To  
Notes
2001-01-08 00:00:00PROVISO; REVISED RISER DIAGRAM REQUIRED
 BEFORE FINAL.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-12-22 Cont ID  
Sent By fknapp Date 2000-12-22 Time 11:13 Rev Time 4.00
Received By fknapp Date 2000-12-22 Time 11:13 Sent To  
Notes
2001-01-08 00:00:00 
  
 ************BUILDING PROVISO************
  
 SBC 104.2.2
  
 1)PROVIDE 2 COMPLETE COPIES OF SBCCI
 OR METRO DADE PRODUCT APPROVALS FOR
 EXTERIOR FRONT DOOR AND SIDE DOOR UNITS.
  
 PLEASE SUBMIT PRIOR TO INSTALLATION.
  
 2)PROVIDE STORM PANEL INFORMATION UNDER
 SEPARATE PERMIT.
  
 3)POOL AND DECK UNDER SEPARATE PERMIT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-12-01 Cont ID  
Sent By fknapp Date 2000-12-01 Time 10:47 Rev Time 4.00
Received By fknapp Date 2000-12-01 Time 08:58 Sent To  
Notes
2001-01-08 00:00:00 
 *************BUILDING UNSAT*************
  
 SBC 104.2.2
  
 1)PROVIDE OWNER/AGENT SIGNATURE ON
 ENERGY CALCULATIONS
  
 2)PROVIDE DESIGN PRESSURES ON PLANS FOR
 ALL EXTERIOR OPENINGS.
  
 3)PROVIDE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE.
  
 4)PROVIDE NOC BEFORE PERMIT CAN BE
 ISSUED.
  
 5)PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR:
 A)ALL EXTERIOR DOORS TO BE USED.
 B)ARCH TRANSOMS
 C)STORM PANELS WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC
 ANCHORS AND MOUNTING TO BE USED.
 D)ROOF COVERING FOR FLAT ROOFS.
 E)WINDOWS WITH APPROVED DRAWINGS
  
 6)PROVIDE LOCATION OF CONNECTORS ON PLAN
 FROM HOLDOWN SCHEDULE.
  
 7)PROVIDE DETAILS OF AHU INSTALLATION IN
 ATTIC.
  
 8)PROVIDE ATTIC VENTILATION SBC 2309.7
  
 9)PROVIDE ATTIC ACCESS SBC 2309.6
  
 10)PROVIDE FIREBLOCKING SBC 705.3
  
 11)PROVIDE STAIR SECTIONS,TREAD RISER
 DIMENSIONS HANDRAIL, GUARDRAIL SBC 1006,
 1007, 1015
  
 12)PROVIDE SAFETY GLASS AS REQUIRED
 SBC 2405.2.1
  
 13)PROVIDE BUCK CONNECTIONS DETAILS FOR
 WINDOW, EXTERIOR DOORS AND GARAGE DOOR
 FOR WINDLOAD RESISTANCE SBC 1606
  
 14)PROVIDE WINDOW IN BR-4 THAT COMPLIES
 WITH EGRESS REQUIREMENTS SBC 1005.4
  
  
 ****************NOTE********************
  
 POOL AND DECK UNDER SEPARATE PERMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-10-30 Cont ID  
Sent By sgraham Date 2000-10-30 Time 13:40 Rev Time 0.25
Received By sgraham Date   Time   Sent To  
Notes
***NONE***