| Plan Review Stops For Permit 00101258 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2000-11-03 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-11-03 |
Time |
15:54 |
Rev Time |
2.00 |
| Received By |
drunnels |
Date |
2000-11-03 |
Time |
15:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-21 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-21 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2000-11-08 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2000-11-08 |
Time |
11:13 |
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-12-12 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-12-12 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-12-12 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLAN REVIEW COMMENTS SEEMED TO ADDRESS | | | ISSUES BY THE FIRE RESCUE DEPARTMENT. | | | ON DECEMBER 12, 2000, WRITER CONTACTED | | | LEWIS AND ASSOCIATES AND ADVISED THEM | | | THAT DOCUMENTATION COULD NOT BE LOCATED | | | FOR THE GENERATOR. | | | | | | CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-10-30 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-10-30 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-10-30 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) WRONG LIFE SAFETY CODE REFERENCED | | | ON PLAN. SHOULD READ NFPA 101 LIFE | | | SAFETY CODE 1985 EDITION INSTEAD OF | | | 1994 EDITION. | | | 2) PLEASE PROVIDE INTERIOR FINISH | | | CLASSIFICATION INFORMATION FOR SPACE. | | | 3) PLEASE PROVIDE MORE DETAILS ON | | | EMERGENCY GENERATOR AND FUEL STORAGE | | | AREA ON GENERATOR. | | | 4) PLANS DO NOT INDICATE IF THE EXISTING | | | BUILDING IS FIRE SPRINKLER PROTECTED. | | | 5) PROVIDE SEPARATE PLANS AND PERMITS | | | FOR NEW FIRE ALARM EQUIPMENT PLANNED | | | FOR BUILDING. | | | 6) SEPARATE PLANS AND PERMITS REQUIRED | | | FOR MEDICAL GAS SYSTEMS. | | | | | | PLANS REVIEWED BY CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 | | | ON 10-30-00 CALLED LEWIS AND ASSOCIATES | | | AND REQUESTED MORE INFORMATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-06-04 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-06-04 |
Time |
09:38 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2001-06-04 |
Time |
09:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-03 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2001-01-03 |
Time |
15:48 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2001-01-03 |
Time |
15:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-11-28 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-11-28 |
Time |
15:18 |
Rev Time |
3.00 |
| Received By |
ndenmark |
Date |
2000-11-28 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************DENIED******************* | | | | | | 1.EXHAUST AIR QUANTITY IS QREATER THAN | | | QUANTITY OF OUTSIDE AIR PROVIDED. | | | EXPLAIN RATIONAL FOR NEGATIVE BUILDING | | | PRESSURE. PROVIDE AIR BALANCE SCHEDULE | | | SHOWING COMPLIANCE WITH 1997 SMC 501.2 | | | | | | NOTE: MEDICAL GAS INSTALLATION REQUIRES | | | ADDITIONAL MECHANICAL PERMIT. PROVIDE | | | TWO SETS OF DETAILED PLANS SHOWING | | | COMPLIANCE WITH 1999 NFPA 99C SPECIFIC | | | TO THIS INSTALLATION AT TIME OF MECHAN- | | | ICAL PERMIT APPLICATION FOR MEDICAL GAS | | | PRIOR TO ANY WORK ON THIS SYSTEM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-01-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-01-19 |
Time |
14:50 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2001-01-19 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2000-12-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-12-20 |
Time |
09:54 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2000-12-20 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | REVIEW NOTES 2,3,AND 4 WERE NOT | | | ADDRESSED; | | | | | | 1.SUBMIT OCCUPANT LOAD BASED ON | | | HABITABLE SQ. FT. AREA PER. SPC | | | 407.1.3. | | | | | | 2.SUBMIT FIRE SAFING DETAILS AND UL | | | ASSEMBLY # FOR PIPE PENETRATIONS THRU | | | RATED WALLS. REFER TO 1996 EDITION OF | | | UL FIRE RESISTIVE DIRECTORY COUNTY- | | | WIDE AMENDMENTS TO SPC SEC 104.2.4 | | | SBC CH.35 | | | | | | THIS PLAN REVIEW DOESNOT INCLUDE | | | MEDICAL GAS. | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 659-8096 EXT.8377 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-11-02 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-11-02 |
Time |
13:22 |
Rev Time |
2.25 |
| Received By |
tlarge |
Date |
2000-11-02 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SHT.ID-1-THE PLUMBING CODE IN EFFECT | | | IS THE 1994 EDITION OF THE STANDARD | | | PLUMBING CODE.COUNTYWIDE AMENDMENT TO | | | SPC SEC.101. | | | | | | 2)SUBMIT OCCUPANT LOAD BASED ON | | | HABITABLE SQ.FOOT AREA PER SPC SEC. | | | 407.1.3.NU | | | | | | 3)FLOORS AND WALLS IN TOILET ROOMS SHALL | | | BE NONABSORBENT TO A HEIGHT OF 4' PER | | | SBC SEC.1204.2. | | | | | | 4)SUBMIT FIRE SAFING DETAIL AND UL | | | ASSEMBLY # FOR PIPE PENETRATIONS THRU | | | RATED WALLS.REFER TO 1996 EDITION OF | | | UL FIRE RESISTIVE DIRECTORY.COUNTYWIDE | | | AMENDMENTS TO SPC SEC.104.2.4.,SBC CH.35 | | | | | | 5)SHT.P-1-HEATER PAN REQS.MIN.OF 1" | | | DRAIN PER SPC SEC.507.8.2. | | | | | | 6)HEATER PAN SHALL COMPLY W/SPC SEC. | | | 507.8.2. | | | | | | 7)VACUUM RELIEF VALVE SHALL COMPLY W/SPC | | | SEC.507.1.2.,ANSI Z21.22. | | | | | | 8)SHT.P-5-VENT FOR SHOWER & F.D.SHALL BE | | | BETWWEN THE FIXTURE DRAINS.SPC 901.2. | | | | | | PLAN REVIEW DOES NOT INCLUDE MEDICAL | | | GAS. | | | | | | CALL IF YOU HAVE ANY QUESTIONS. | | | 561-8096 EXT.8377. | | | | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|