| Plan Review Stops For Permit 00101227 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2001-12-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-12-18 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-12-18 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2000-12-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-18 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-18 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2000-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-30 |
Time |
20:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-30 |
Time |
20:55 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ****************** | | | | | | 1)NOTE: AS ASKED FOR AND REQ`D FROM | | | FIRST REVIEW. PLEASE SUBMIT AIC RATING | | | FOR MAIN AND PANELS. PER 110-9/215-5 | | | | | | 2)NOTE: PLEASE NOTE ALL OUTLETS SERVING | | | KITCHEN COUNTERSPACE ARE TO BE GFI/GFI | | | PROTECTED PER 210-8-A-6 PLEASE SHOW | | | | | | 3)NOTE: PLEASE SEE MISSING SD LOWER | | | LEVEL. | | | | | | 4)NOTE: PLEASE NOTE THAT THE PLANS ARE | | | NOW SHOWING COMPLETE REWIRE? IF CATV | | | AND TELEPHONES ARE GOING TO BE INSTALLED | | | THEN THEY MUST BE ON PLAN??? | | | | | | 5)NOTE: PLEASE NOTE THAT NO PANEL SCHED- | | | -ULE WAS SUBMITTED AND MISSING BATH(S) | | | CIRCUIT(S) PER 210-11-C-3. AS ASKED FOR | | | ON PREVIOUS REVIEW. | | | | | | 6)NOTE: PLEASE SEE LOAD CALCULATIONS? | | | YOU SHOW TWO SEPARATE A/C UNITS? PLEASE | | | SHOW THESE ON PLANS AND SHOW DISCONNECTS | | | PER 440-11 AND GFI PER MECH CODE 309.1 | | | PLEASE SHOW IN HOUSE AHU`S. | | | AS ON PREVIOUS NOTE IF THERE ARE EXIST- | | | -ING ELECTRICAL CONDITIONS?? PLEASE SHOW | | | AND PROVIDE CLARIFICATION. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-03 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-03 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ******************* | | | | | | 1)NOTE: NO ELECTRICAL WAS SUBMITTED FOR | | | NEW ADDITION AREA. PLEASE SUBMIT. | | | | | | 2)NOTE: THE ELECTRICAL THAT WAS SUBMIT- | | | -TED FOR SECOND FLOOR IS FOR WHAT? IS | | | THIS AREA BEING REWIRED? IF SO PLEASE | | | MAKE NOTE ON PLANS FOR CLARIFICATION. | | | | | | 3)NOTE: ALSO PLEASE NOTE THAT A SD WILL | | | BE REQ`D ON THE FIRST LEVEL AT THE BOT- | | | -TOMOF THE STAIRS,,, NFPA-72 | | | | | | 4)NOTE: PLEASE SUBMIT AIC RATING FOR | | | ALL EQUIPMENT BEING INSTALLED. PER 110-9 | | | AND 215-5 | | | | | | 5)NOTE: PLEASE LIST THE REQ`D BATH(S) | | | CIRCUIT(S) ON PANEL SCHEDULE PER 210-52D | | | AND 210-11-C-3 | | | | | | 6)NOTE: PLEASE NOTE THAT IF THERE IS | | | GOING TO BE ANY CATV OR TELEPHONES | | | UPSTAIRS THEN PLEASE DRAW ON PLAN. IF | | | THEY ARE EXISTING THEN DISREGUARD. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2000-11-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-04 |
Time |
07:29 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2000-11-04 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | NO A/C PLAN; | | | A/C CONTRACTOR TO PROVIDE A/C PLAN WITH | | | PERMIT APPLICATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-12-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-12-05 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEE APPROVAL BY JOHN LEECH ON BACK OF | | | APPLICATION. | | | L.MARTINEZ 12/5/00 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2000-10-29 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-29 |
Time |
08:58 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-10-29 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)SUBMIT SANITARY AND WATER RISER | | | DIAGRAMS FOR REVIEW THAT REFLECT ENTIRE | | | SCOPE OF WORK TO BE PERFORMED. | | | | | | CALL IF YOU HAVE QUESTIONS. | | | 5610659-8096,EXT.8377. | | | | | | TIMOTHY LARGE | | | PLUMBING PLANS EXAMINER. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-12-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-12-05 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-11-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2000-11-07 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | BUILDING COMMENTS | | | ------------------- | | | | | | 1] | | | NEW 8"CMU FENCE WILL NOT BE PART OF THIS | | | PERMIT. | | | | | | 2] | | | APPLICATION CALLS FOR CHANGING INTERIOR | | | DOORS,PLAN SHOWS NEW EXTERIOR DOORS, | | | GARAGE AND FRENCH,TEST REPORTS ARE | | | REQUIRED FOR EXTERIOR DOORS,WINDOWS | | | AND ROOF COVERS,ALL NEW GLAZING SHALL | | | BE IMPACT PROTECTED. | | | | | | 3] | | | PROVIDE FOUNDATION PLAN,WALL SECTIONS | | | SHALL INCLUDE ALL VERTICAL REINFORCEMENT | | | CONTIUOUS THRU TIE BEAM,BE SPECIFIC WITH | | | THE CONNECTION OF ROOF SYSTEM AND WALLS. | | | | | | 4] | | | SUPPLY DETAIL FOR BRACKET BEAM AND OVER- | | | HANG AT GARAGE. | | | | | | 5] | | | PROVIDE DETAIL FOR NEW PARAPET AT GARAGE | | | | | | 6] | | | SUBMIT INTERIOR WALL SECTIONS,WILL ANY | | | INSULATION BE APPLIED? | | | | | | 7] | | | A RECORDED NOTICE OF COMMENCEMENT SHALL | | | BE SUBMITTED BEFORE PERMIT ISSUANCE. | | | | | | | | | | | | REVIEWED BY: | | | LUIS MARTINEZ | | | 659-8096 | | | EXT. 8456 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-11-03 |
|
|
Cont ID |
|
| Sent By |
sgraham |
Date |
2000-11-03 |
Time |
11:00 |
Rev Time |
0.25 |
| Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|