| Plan Review Stops For Permit 00101172 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-11-14 |
Time |
10:06 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-11-14 00:00:00 | PROVISO: SEE PROVISO ON PLANS/ REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-20 |
Time |
11:04 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2001-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-08 |
Time |
10:45 |
Rev Time |
7.00 |
| Received By |
jwitmer |
Date |
2001-06-21 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2001-07-08 00:00:00 | BUILDING PLAN REVIEW | | | 921 ORTEGA RD | | | J L HAWKINS | | | P: 966-6383 | | | | | | SBC= REFRENCES TO STANDARD BUILDING CODE | | | 1997 EDITION | | | | | | 1)- SBC 1606.4.1/1707.4.1 AMEND. REQUIES | | | PRODUCT TESTING FOR COMPONENTS & CLAD- | | | DING MISSING ARE THE PRODUCT APPROVAL | | | REPORTS FOR THE NEW FRONT ENTRY DOORS. | | | | | | 1B)- STORM SHUTTERS : THERE IS NO FASTEN | | | ING SCHEDULE NOR IS THERE AND INSTALLA-T | | | ION KEY FOR WINDOW TO SHUTTER LOCATION. | | | | | | 1C)- DISCREPANCY: THE WINDOW PRODUCT APP | | | ROVAL REPORT IS FOR CASEMENT WINDOWS BUT | | | THE PLANS INDICATE SINGLE HUNG OR AWNING | | | TYPE WINDOW IN ELEVATION VIEW? SLEEPING | | | ROOMS REQUIRE EMERGENCY ESCAPE & RESCUE | | | OPENINGS MINIMUM SIZES SBC 1005.4. | | | | | | ROOF FRAMING PLAN : MANSARD ROOF- NOTE- | | | SBC TABLE 2308.1"D"NOTE 4 ALLOWS 5/8" | | | DIRECT APPLICATION ONTO 2X4 STUDS, THE | | | PLYWOOD IF GROOVED, GROOVES NO WIDER | | | THAN 1 1/2" & SPACED NO CLOSER THAN 12" | | | O.C. WHAT WILL BE USED FOR BACKING FOR | | | THE FLASHING SINCE THERE IS NO SUB- | | | SUBSHEATHING AND THE FINISH SIDING CAN'T | | | GO TO THE ROOF DECK AS INDICATED ON THE | | | NEW DETAIL? NEW ROOF PLAN SECTION A DOES | | | NOT GIVE ANY STRAPPING INFO? | | | | | | 3)- PROVIDE NOTICE OF COMMENCEMENT | | | RECORDED AT THE CLEAK OF THE COUNTY | | | COURT OFFICE BEEFORE THE PERMIT CAN BE | | | ISSUED. | | | | | | PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-11-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-06 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-06 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ***************** PROVISO ************** | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATING OF MAIN | | | /PANEL BEFORE FINAL. PER 110-9 AND 215-5 | | | | | | 2)NOTE;PLEASE REVISED PLANS TO CORRELATE | | | WITHRELINED ITEMS AND ANY AS-BUILTS. | | | 215-5 | | | | | | PLEASE SUBMIT ALL THE ABOVE INFORMATION | | | FOR REVIEW BEFORE FINAL ELECTRICAL INSPE | | | -CTION IS CALLED IN. IF THERE ARE ANY | | | QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2001-06-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-06-21 |
Time |
09:17 |
Rev Time |
0.25 |
| Received By |
pkrauss |
Date |
2001-06-21 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2001-06-21 00:00:00 | NO REVISION TO MECHANICAL - J. LEECH | | | APPROVED 3/10/01. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2001-03-10 |
Time |
08:42 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2001-03-10 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2000-11-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2000-11-06 |
Time |
17:29 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2000-11-06 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | DENIED; | | | 1.SIZE ALL DUCTWORK AND DROPS. | | | 2.LIST CFM'S FOR EACH DROP. | | | 3.SHOW RETURN AIR LOCATIONS AND SIZE. | | | 4.LIST EQUIPMENT SPECIFICATIONS; | | | A.MANUFACTOR | | | B.MODEL NUMBERS | | | C.HEAT STRIP SIZE AND FUSE SIZE | | | D.SEER RATE |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2001-11-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-07 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2001-11-07 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2001-11-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-11-06 |
Time |
19:55 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-11-06 |
Time |
19:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2001-10-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2001-10-30 |
Time |
19:58 |
Rev Time |
0.50 |
| Received By |
kstevens |
Date |
2001-10-30 |
Time |
19:58 |
Sent To |
|
|
| Notes |
| 2001-10-30 00:00:00 | DENIED | | | | | | SIGNED AND SEALED PLANS SHALL HAVE SIGN- | | | ED AND SEALED REVISIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-11-15 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-11-15 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
fknapp |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | OK PER T.LARGE |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2001-07-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-07-20 |
Time |
11:05 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2001-03-15 |
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2001-03-15 |
Time |
16:25 |
Rev Time |
3.00 |
| Received By |
jwitmer |
Date |
2001-03-15 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2001-03-15 00:00:00 | *************BUILDING UNSAT************* | | | | | | SBC 104.2.2 | | | | | | 1) PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | ALL EXTERIOR DOORS AND WINDOWS | | | MULLIONS | | | ROOF COVER | | | | | | 2) PROVIDE STORM PANEL INFORMATION WITH | | | INSTALLATION SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING. | | | | | | 3) PROVIDE ENERGY CALCULATIONS THAT HAVE | | | SIGNATURE OF OWNER/AGENT COMPLETE WITH | | | MANUAL J FORM. | | | | | | 4) PROVIDE ROOF FRAMING PLAN. | | | | | | 5) PROVIDE NOTES ON SHEET A-4 THAT | | | REFERENCES 1997 SBC ANDHAS CORRECT | | | MEAN ROOF HEIGHT. | | | | | | 6) PROVIDE DESIGN COMPLIANCE FORM THAT | | | MATCHES DESIGN OF PLANS. | | | | | | 7) PROVIDE DETAILS WITH DIMENSIONS OF | | | GUARDRAIL AND HANDRAILS PER 1997 SBC | | | 1007.5 AND 1015 | | | | | | 8) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | ANY QUESTIONS PLEASE CALL, | | | FRANK KNAPP | | | BUILDING PLAN REVIEW | | | DEPARTMENT OF CONSTRUCTION SERVICES | | | CITY OF WEST PALM BEACH | | | (561) 659-8096 EXT. 8392 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
fknapp |
Date |
2000-11-15 |
Time |
14:27 |
Rev Time |
4.00 |
| Received By |
fknapp |
Date |
2000-11-15 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | | | | | | | ************BUILDING UNSAT************** | | | | | | SBC 104.2.2 | | | | | | 1)PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | ALL EXTERIOR DOORS AND WINDOWS | | | MULLIONS | | | ROOF COVER | | | | | | 2)PROVIDE INSTALLATION SCHEDULE AND KEY | | | PLAN FOR STORM PANELS WITH SPECIFIC | | | ANCHORS TO BE USED. | | | | | | 3)PROVIDE ENERGY CALCULATIONS COMPLETE | | | WITH MANUAL J. | | | | | | 4)PROVIDE DESIGN CERTIFICATION FOR | | | BUILDING CODE COMPLIANCE. | | | | | | 5)PROVIDE DETAILS FROM REGISTERED | | | ENGINEER FOR SUPPORTING FOUNDATION AND | | | STRUCUAL REPAIRS. | | | | | | 6)PROVIDE ROOF FRAMING PLAN. | | | | | | 7)PROVIDE NOTES THAT REFERENCE 1997 SBC | | | AND HAVE CORRECT MEAN ROOF HEIGHT. | | | | | | 8)PROVIDE BR WINDOWS THAT COMPLY WITH | | | EGRESS 1997 SBC 1005.4 | | | | | | 9)PROVIDE ROOF SHEATHING NAILING ZONES | | | PER CITY AMENDMENTS 1997 SBC FIG.2306.1 | | | | | | 10)PROVIDE WINDOW AND DOOR BUCK | | | CONNECTION DETAILS PER 1997 SBC 1606 | | | | | | 11)PROVIDE DETAILS WITH DIMENSIONS OF | | | GUARDRAIL AND HANDRAILS PER 1997 SBC | | | 1007.5 AND 1015 | | | | | | 12)PROVIDE NEW VALUE OF WORK TO BE DONE | | | TO INCLUDE LABOR AND MATERIAL. | | | | | | 13)PROVIDE A COURT RECORDED NOC BEFORE A | | | PERMIT CAN BE ISSUED. |
|
|