| 2001-01-08 00:00:00 | DENIED |
| | |
| | 1)IMPACT FEES MUST BE PAID TO PALM BEACH |
| | COUNTY,PLANS STAMPED BY THEM AND RECEIPT |
| | SUBMITTED TO CITY OF WPB BUILDING DEPT. |
| | BEFORE A PERMIT TO CONSTRUCT WILL BE |
| | ISSUED. |
| | |
| | 2)SPECIFY INSULATION THAT WILL BE |
| | INSTALLED IN WALLS AND CEILING. |
| | |
| | 3)PROVIDE ENERGY CALCULATIONS AND MANUAL |
| | "J" CALCS IF ROOM IS TO BE MECHANICALLY |
| | HEATED OR COOLED. |
| | |
| | 4)PROVIDE DETAILS FOR METHODS OF ATTACH- |
| | MENT OF NEW FOOTINGS, WALLS AND ROOF |
| | TRUSSES TO EXISTING STRUCTURE. |
| | |
| | 5)ATTIC SPACES SHALL BE PROVIDED WITH |
| | AN INTERIOR ACCESS OPENING NOT LESS THAN |
| | 22 X 36 INCHES. 97 SBC 2309.6 |
| | |
| | 6)THE BOXED 2 ON NOTE 1 OF EXTERIOR |
| | WALLS STATES 2" X 6" STUDS 3 NAILED |
| | TOGETHER TO SUPPORT HEADER. THE NOTE |
| | INDICATES 2" X 4" WALLS 16" O.C. PLEASE |
| | CLARIFY. |
| | |
| | 7)WHERE LATH AND STUCCO FINISH IS |
| | APPLIED OVER THE EXTERIOR OF WOOD FRAMED |
| | CONSTRUCTION, AN APPROVED STUCCO STOP |
| | PLACED NOT LESS THAN 6" ABOVE FINISH |
| | GRADE SHALL BE USED TO TERMINATE THE |
| | STUCCO AT THE BASE OF THE WALL. 2304.2.5 |
| | OF CITY AMENDMENTS TO 97 SBC. |
| | |
| | 8)PROVIDE NAME AND SIGNATURE OF PERSON |
| | RESPONSIBLE FOR THE DESIGN. 97 SBC 104.2 |
| | |
| | 9)EXTERIOR DOOR MUST BE LOCATED SO AS |
| | NOT TO INTERFERE WITH EGRESS FROM STAIRS |
| | TO SECOND STORY. |
| | |
| | 10)PLEASE SPECIFY TRUSS SPACING. |
| | |
| | 11)PROVIDE SOIL COMPACTION TEST AT 1ST |
| | INSPECTION. |
| | |
| | 12)PROVIDE 2 CURRENT COPIES OF SBCCI OR |
| | METRO-DADE PRODUCT APPROVALS FOR ROOFING |
| | MATERIALS AND DOOR. APPROVALS MUST BE |
| | COMPLETE AND NOT HAVE EXPIRED. |
| | |
| | 13)A RECORDED NOTICE OF COMMENCEMENT |
| | MUST BE SUBMITTED BEFORE BUILDING PERMIT |
| | WILL BE ISSUED. |