Plan Review Details - Permit 00100646
Plan Review Stops For Permit 00100646
Review Stop E ELECTRICAL
Rev No 4 Status P Date 2001-10-23 Cont ID  
Sent By dpalmer Date 2001-10-23 Time 19:14 Rev Time 0.00
Received By dpalmer Date 2001-10-23 Time 19:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2001-10-09 Cont ID  
Sent By dpalmer Date 2001-10-09 Time 12:21 Rev Time 0.00
Received By dpalmer Date 2001-10-09 Time 12:21 Sent To  
Notes
2001-10-09 00:00:00UNSAT
  
 1)NOTE; PLANS ARE TO BE SIGNED, DATED,
 AND SEALED BY ENGINEER OF RECORD.
 471.025
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2000-12-11 Cont ID  
Sent By dpalmer Date 2000-12-11 Time 18:13 Rev Time 0.00
Received By dpalmer Date 2000-12-11 Time 18:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-11-06 Cont ID  
Sent By dpalmer Date 2000-11-06 Time 20:42 Rev Time 0.00
Received By dpalmer Date 2000-11-06 Time 20:42 Sent To  
Notes
2001-01-08 00:00:00**************** UNSAT ****************
  
 1)NOTE: SMOKE DETECTORS ARE REQ`D INSIDE
 AND OUTSIDE ALL SLEEPING ROOMS AND ON
 EACH LEVEL OF A MULTI-LEVEL RESIDENCE.
 PER NFPA-72 2-2.1.1.1
  
 2)NOTE: PLEASE SEE LIGHT FIXTURE TYPE IN
 BEDROOM #2 AND SEE 410-8 OF THE NEC.
  
 3)NOTE: PLEASE SEE 210-52 FOR OUTLETS
 ALONG KITCHEN WALL SPACE.
  
 4)NOTE: PLEASE SEE OUTLET SPACING IN
 PENTHOUSE PER 210-52. HANDRAILS ARE
 CONSIDERED WALL SPACE PER NEC.
  
 5)NOTE: PLEASE SEE PANEL SCHEDULE "A"
 IT SHOWS FEEDING PANEL "B1" INSTEAD OF
 PANEL A1?? PLEASE CORRECT.
  
 6)NOTE: PLEASE NOTE THAT NO CONDUIT AND
 CONDUCTOR SIZES ARE SHOWN FROM MAIN
 DISCONNECTS TO PANELS "A" AND "B".
 PLEASE SHOW. ALSO SHOW CONDUCTORS FROM
 METER TO GUTTER ETC. PLEASE INDICATE
 GUTTER SIZE PER NEC 374.
  
 7)NOTE: PLEASE INCLUDE BLDG. STEEL AS
 PART OF THE GROUNDING ELECTRODE SYSTEM
 REQ`D PER 250-50.
  
 8)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL EQUIPMENT BEING INSTALLED. MAIN DISC
 -ONNECTS/PANELS. ALL MUST BE RATED FOR
 THE AVAILABLE FAULT CURRENT PER 110-9.
 PLEASE SUBMIT RATING PER 215-5.
  
 9)NOTE: PLEASE LIST THE REQ`D DEDICATED
 BATH(S) CIRCUIT(S) PER 210-52/210-11-C-3
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRCIAL PLAN REVIEW.
 561-659-8096 EXT8372

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2001-07-23 Cont ID  
Sent By pkrauss Date 2001-07-23 Time 09:48 Rev Time 0.45
Received By pkrauss Date 2001-07-23 Time 09:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-11-02 Cont ID  
Sent By jleech Date 2000-11-02 Time 20:17 Rev Time 1.00
Received By jleech Date 2000-11-02 Time 20:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2001-01-04 Cont ID  
Sent By jleech Date 2001-01-04 Time 08:34 Rev Time 0.25
Received By jleech Date 2001-01-04 Time 08:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-12-28 Cont ID  
Sent By jleech Date 2000-12-11 Time 10:56 Rev Time 0.50
Received By jleech Date 2000-12-11 Time 10:56 Sent To  
Notes
2001-01-08 00:00:00SECONDARY DRAIN PROTECTION REQUIRED FOR
 ROOF DRAIN SYSTEM. SPC 1109.2 AND SBC
 1517.6.4. SIZE SCUPPERS BY SPC APPX A
 TABLE A101.2.

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-10-31 Cont ID  
Sent By tlarge Date 2000-10-31 Time 10:35 Rev Time 0.75
Received By tlarge Date 2000-10-31 Time 10:35 Sent To  
Notes
2001-01-08 00:00:001)SUBMIT STORM RISER DIAGRAM SHOWING
 SQUARE FOOTAGE DRAINED BY EACH DRAIN.
 COMPLY W/SPC TABLES 1108.1,1108.2.
  
 2)SUBMIT DEATILS AND CALCULATIONS FOR
 OVERFLOW DRAINAGE.COMPLY W/SPC SECS.
 1109.1-1109.3.AND APPENDIX A,
 TABLE A101.2.
  
 3)2ND FLOOR WATER HEATER SHALL BE
 EQUIPPED W/PAN AND PAN DRAIN AND SHALL
 COMPLY W/SPC SEC.5078.8.1.-507.8.4.
  
 4)CLEARLY SHOW DIMENSIONS (LXW)OF ALL
 SHOWERS.
  
 CALL IF YOU HAVE QUESTIONS.
 561-659-8096,EXT.8377
  
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2001-11-29 Cont ID  
Sent By lmartine Date 2001-11-29 Time 09:43 Rev Time 1.00
Received By lmartine Date   Time   Sent To  
Notes
2001-11-29 00:00:00 
 MAILBOX SUBMITTAL IS IN THE CITY RIGHT
 OF WAY, APPROVAL SHALL COME FROM
 ENGINEERING DEPARTMENT.
  
 L. MARTINEZ

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2001-01-05 Cont ID  
Sent By lmartine Date 2001-01-05 Time 07:39 Rev Time 0.00
Received By lmartine Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-11-20 Cont ID  
Sent By drunnels Date 2000-11-20 Time 08:57 Rev Time 3.00
Received By drunnels Date 2000-11-20 Time 08:57 Sent To  
Notes
2001-01-08 00:00:001]SUBMIT PLAND SHOWING STAIRS COMPLYING
 WITH SECTION 1007.0 1997 SBC.
 2]SUBMIT PLANS SHOWING PENTHOUSE
 COMPLYING WITH TABLE 500 1997 SBC.
 3]SUBMIT OLANS SHOWING BEDROOM WINDOWS
 COMPLYING WITH SECTION 1005.4 1997 SBC.
 4]POOL AND FENCES REQUIRE SEPERATE
 PERMITS.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-10-23 Cont ID  
Sent By gjoyce Date 2000-10-23 Time 09:53 Rev Time 0.25
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***