| Plan Review Stops For Permit 00100624 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2001-03-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-03-27 |
Time |
14:22 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-01-25 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2001-01-25 |
Time |
14:58 |
Rev Time |
0.25 |
| Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2000-12-01 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-12-01 |
Time |
14:24 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-12-01 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-10-25 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-10-25 |
Time |
11:18 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-10-25 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. SUBMIT PRODUCT APPROVAL FOR IMPACT | | | RESISTANCE GLAZING FOR STOREFRONT WINDOW | | | AND DOORS/ METRO DADE COUNTY OR SBCCI | | | 2. SUBMIT FIRE SPRINKLER PLANS AND | | | PERMIT APPLICATION | | | 3. SUBMIT LETTER FROM SPECIAL INSPECTOR | | | FOR CITY PLACE | | | 4. SIGNS TO BE UNDER SEPRATE PERMIT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-26 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-26 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-12-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-11 |
Time |
22:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-11 |
Time |
22:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-11-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-01 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-01 |
Time |
18:31 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1)NOTE: PLEASE SUBMIT AIC RATING FOR | | | MAIN DISCONNECT. AIC RATING SHOWN FOR | | | BRKRS IN PANEL BUT NOT FOR PANEL OR | | | MAIN. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION PER | | | 110-9 AND 215-5 FOR REVIEW. PLANS WOULD | | | HAVE PASSED WITH A PROVISO BUT WERE | | | COMING BACK FOR OTHER COMMENTS. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-11-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-28 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-28 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-10-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-10-16 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-10-16 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO HYDRAULIC CALCULATIONS PROVIDED | | | WITH FIRE SPRINKLER DRAWINGS. | | | 2) PROVIDE FIRE ALARM SYSTEM SHOP | | | DRAWINGS FOR FIRE ALARM EQUIPMENT SHOWN | | | ON PLANS. | | | 3) A FIRE ALARM STROBE IS REQUIRED IN | | | THE TOILET ROOM. | | | | | | PLANS REVIEWED BY CAPTAIN MIKE CARSILLO | | | 659-8096,EXT.8497 | | | 835-2910 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-12-14 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-12-14 |
Time |
10:35 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-12-14 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEE ATTACHED LETTER FROM ENGINEER FOR | | | PROVISO CORRECTION ATTACHED TO APPR PLAN |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-11-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-11-06 |
Time |
14:55 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-11-06 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | 1. PLEASE PROVIDE LETTER (X2) DETAILING | | | ATTACHEMENT OF AHU TO CEILING AND C/U | | | TO EQUIPMENT STAND. | | | 2. MINIMUM 18" CLEARANCE REQUIRED | | | BETWEEN ROOF SURFACE AND BOTTOM OF | | | SUPPORT STRUCTURE OF STAND |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-10-21 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-21 |
Time |
12:58 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-10-21 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|