| Plan Review Stops For Permit 00100488 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2001-03-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2001-03-27 |
Time |
14:24 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-03-27 00:00:00 | REVISIONS: STOREFRONT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2001-01-25 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2001-01-25 |
Time |
15:00 |
Rev Time |
0.25 |
| Received By |
drunnels |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2000-10-25 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-10-25 |
Time |
10:33 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-10-25 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1. SUBMIT PRODUCT APPROVAL FOR IMPACT | | | RESISTENT GLAZING ON STOREFRONT WINDOWS | | | AND DOORS/METRO DADE COUNTY OR SBCCI | | | 2.SUBMIT FIRESPRINKLER PLANS AND PERMIT | | | APPLICATION | | | 3.SUBMIT LETTER FROM SPECIAL INSPECTOR | | | FOR CITY PLACE |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2001-03-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2001-03-26 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2001-03-26 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2000-12-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-12-11 |
Time |
22:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-12-11 |
Time |
22:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2000-11-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-01 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-01 |
Time |
17:37 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | ************** UNSAT ******************* | | | | | | 1)NOTE:PLEASE NOTE THAT THE AIC RATING | | | FOR BRKRS INSATLLED IN PANEL SHOWS | | | THEM AT 10,000A. THIS IS FINE BUT NO | | | AIC RATINGS WERE SUBMITTED FOR MAIN | | | DISCONNECT. PLEASE SUBMIT AIC RATING FOR | | | MAIN DISC. PLANS WOULD HAVE PASSED WITH | | | PROVISO BUT WERE COMING BACK FOR OTHER | | | COMMENTS. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 659-8096 EXT 8372 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2000-11-28 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-11-28 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-11-28 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2000-10-16 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2000-10-16 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2000-10-16 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1) NO HYDRAULIC CALCULATIONS PROVIDED | | | WITH FIRE SPRINKLER DRAWINGS. | | | 2) A FIRE ALARM STROBE IS NEEDED IN | | | THE TOILET ROOM. | | | 3) AN EXIT SIGN IS NEEDED ABOVE THE | | | REAR EXIT DOOR. | | | 4) WHAT TYPE OF MATERIAL IS THE CURTAIN | | | AND IS IT FLAMMABLE. | | | 5) EXITING THROUGH THE STOCKROOM IS | | | PERMITTED IF THE FOLLOWING CONDITIONS | | | ARE MET, AN AISLE OF AT LEAST 44" IS | | | TO BE PROVIDED AND MAINTAINED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2000-12-14 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-12-14 |
Time |
10:29 |
Rev Time |
0.25 |
| Received By |
ndenmark |
Date |
2000-12-14 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | SEE ATTACHED LETTER FROM ENGINEER |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-11-06 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-11-06 |
Time |
14:27 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-11-06 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PROVISO: | | | 1. LETTER FROM ENGINEER DETAILING | | | ATTACHEMENT OF C/U TO STAND AND AHU TO | | | CEILING TO FOLLOW PRIOR TO INSPECTION | | | ON EQUIPMENT | | | 2. MINIMUM CLEARANCE BETWEEN ROOF SURFAC | | | AND BOTTOM OF SUPPORT STRUCTURE OF EQUIP | | | STAND IN 18". | | | 3. 250 CFM SUPPLY AIR SHOWN ON RETURN | | | SIDE OF AHU IS RETURN AIR NOT SUPPLY | | | PER D. ROMCKE |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2000-12-10 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-12-10 |
Time |
08:00 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLUMBING PLAN REVIEWPROVISO | | | PREVIOUS COMMENTS NOT ADDRESSED. | | | (1) SHT A2-SINK TO COMPLY W/ FACBC | | | SEC 4.24.1 NO HIGHER 34" ABOVE FF. | | | SEC 4.24.1 KNEE CLEARANCE 27" HIGH. | | | 30" WIDE, 19" DEEP,SHALL BE PROVIDED. | | | SEC. 4.24.5 CLEAR FLR SPACE 30" X 48". | | | (2) SEC 4.1.3 (16) (A) SIGNAGE H/C. | | | (3) SHT MP-1 AIR CHAMBERS SEC 607.8.3 | | | TO BE ACCESSIBLE, RECHARGEABLE. | | | END OF COMMENTS PAUL SCHMITZ | | | 561-659-8096 X 8233 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-10-21 |
|
|
Cont ID |
|
| Sent By |
tlarge |
Date |
2000-10-21 |
Time |
11:20 |
Rev Time |
0.33 |
| Received By |
tlarge |
Date |
2000-10-21 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|