Plan Review Details - Permit 00100482
Plan Review Stops For Permit 00100482
Review Stop E ELECTRICAL
Rev No 5 Status P Date 2001-11-07 Cont ID  
Sent By dpalmer Date 2001-11-07 Time 08:33 Rev Time 0.00
Received By dpalmer Date 2001-11-07 Time 08:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2001-10-29 Cont ID  
Sent By dpalmer Date 2001-10-29 Time 20:09 Rev Time 0.00
Received By dpalmer Date 2001-10-29 Time 20:09 Sent To  
Notes
2001-10-29 00:00:00***************** UNSAT ***************
  
 1)NOTE: PLEASE NOTE THAT PLANS MUST
 CONTAIN THE TITLE BLOCK FOR THE ENGINEER
 OF RECORD. PER FS/FAC 471.025/ ALSO
 61G15-23.002
  
 2)NOTE: PLEASE NOTE THAT ALSO THAT PLANS
 THAT CONTAIN TITLE BLOCKS LIKEWISE ARE
 REQ`D TO BE SIGNED,DATED AND SEALED BY
 THE ENGINEER OF RECORD. 471.025
  
 3)NOTE: PLEASE NOTE THAT PLANS SUBMITTED
 SHOW PANEL SCHEDULES SHOW FOUR PANELS?
 AND YET RISER DIAGRAM SHOWS ONLY TWO
 PANELS.
  
 4)NOTE: PLEASE NOTE THATS PLANS NEED TO
 BE IN A PRINTED(COPIED) DOCUMENT. THESE
 ARE HANDWRITTEN PLANS FOR FINAL.
 PLEASE SUBMIT PRINTED PLANS FOR FINAL.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2000-12-28 Cont ID  
Sent By dpalmer Date 2000-12-28 Time 15:00 Rev Time 0.00
Received By dpalmer Date 2000-12-28 Time 15:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2000-12-26 Cont ID  
Sent By dpalmer Date 2000-12-26 Time 12:22 Rev Time 0.00
Received By dpalmer Date 2000-12-26 Time 12:22 Sent To  
Notes
2001-01-08 00:00:00***************** UNSAT ****************
  
 NOTES FROM FIRST REVIEW, NOT ALL WERE
 ADDRESSED.
  
 1)NOTE: PLEASE SUBMIT AIC RAATINGS FOR
 ALL NEW EQUIPMENT. MAINS AND PANELS ARE
 TO BE RATED FOR THE AVAILABLE FAULT
 CURRENT. SAYING THE PANEL/MAIN IS AIC
 RATED DOES NOT GIVE THE RATING. ALL
 EQUIPMENT HAS DIFFERENT RATINGS FOR
 DIIERENT FAULTS. PLEASE CONTACT FPL
 AND CALL IF ANY QUESTIONS.
  
 2)NOTE: PLEASE SEE LOADS SHOWN ON PANEL
 SCHEDULE. LOADS FAR EXCEED THE RATINGS
 OF 80% OF BRKR.384-16
 LOADS SHOWN AT 2.5KW,1.8KW AND 1.5KW
 ON 15A AND 20A BRKRS.
  
 3)NOTE: PLEASE NOTE THAT PANEL SCHEDULE
 SHOWS ALL WIRING TO BE IN CONDUIT.???
 PLEASE VERIFY AND CHANGE IF NESS.
  
 4)NOTE: PLEASE SEE MISSING OUTLETS PER
 210-52 2` OF WALL IN BEDROOMS, 2,3,4.
  
 5)NOTE: PLEASE NOTE MISSING GFI OUTLET
 FOR A/C EQUIPMENT OUTSIDE. PER 309.1
 OF MECH CODE
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 ETX 8372

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2000-10-25 Cont ID  
Sent By dpalmer Date 2000-10-25 Time 00:25 Rev Time 0.00
Received By dpalmer Date 2000-10-25 Time 00:25 Sent To  
Notes
2001-01-08 00:00:00*************** UNSAT *****************
  
 1)NOTE: PLEASE LIST THE REQ`D BATHS PER
 210-52D AND 210-11-C-3. #12 AND 20A
  
 2)NOTE: PLEASE SEE LOAD CALCULATIONS,
 YOU SHOW 13.8KW FOR GEN LIGHTING IN
 LOWER CORNER OF PANEL AND 3.8KW ON
 PANEL SCHEULE.PLEASE CORRLELATE.
  
 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 BOTH MAIN AND PANEL. BOTH MUST BE RATED
 FOR THE AVAILABLE FAULT CURRENT PER
 110-9 AND 215-5.
  
 4)NOTE: PLEASE SHOW BLDG STEEL AS PART
 OF THE GROUNDING ELECTRODE SYSTEM PER
 250-50.
  
 5)NOTE: PLEASE SHOW CONDUCTORS FROM
 METER TO MAIN DISC AND FROM MAIN DISC TO
 PANEL.
  
  
 PLEASE SUBMIT ALL THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESTIONS
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-659-8096 EXT 8372

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-10-24 Cont ID  
Sent By jleech Date 2000-10-24 Time 19:28 Rev Time 0.50
Received By jleech Date 2000-10-24 Time 19:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2001-11-26 Cont ID  
Sent By kstevens Date 2001-11-26 Time 13:31 Rev Time 0.50
Received By kstevens Date 2001-11-26 Time 13:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2000-10-23 Cont ID  
Sent By tlarge Date 2000-10-23 Time 07:33 Rev Time 0.50
Received By tlarge Date 2000-10-23 Time 07:33 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-12-28 Cont ID  
Sent By rmcdouga Date 2000-12-28 Time 15:45 Rev Time 2.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00PROVISO
  
 PROVIDE KEY PLAN AND INSTALLATION
 SCHEDULE FOR STORM PANELS UNDER SEPARATE
 PERMIT.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-11-28 Cont ID  
Sent By rmcdouga Date 2000-11-28 Time 14:18 Rev Time 4.00
Received By rmcdouga Date   Time   Sent To  
Notes
2001-01-08 00:00:00DENIED
  
 1)IMPACT FEES MUST BE PAID TO P.B.COUNTY
 PLANS STAMPED BY THEM AND RECEIPT
 SUBMITTED TO CITY BUILDING DEPT. BEFORE
 PERMIT CAN BE ISSUED.
  
 2)RECORDED COPY OF NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE
 PERMIT CAN BE ISSUED.
  
 3)FLORIDA ENERGY CODE FORMS MUST BE SIGN
 -ED BY OWNER OR AGENT.
  
 4)SURVEY DOES NOT CORRESPOND WITH SITE
 PLAN ON ARCHITECTURAL DRAWINGS. PLEASE
 REVIEW AND CORRECT.
  
 5)THE STAIRS FROM 1ST FLOOR TO 2ND FLOOR
 DO NOT COMPLY WITH CODE.THE SUM OF 2
 RISERS AND A TREAD, EXCLUSIVE OF PROJECT
 -ION OF THE NOSING, IS NOT TO BE LESS
 THAN 24" NOR MORE THAN 25". 97 SBC1007.3
  
 6)DOOR FROM GARAGE TO CONDITIONED AREA
 OF STRUCTURE MUST COMPLY WITH 403.1 OF
 97 FL. ENERGY EFFICIENCY CODE.
  
 7)ENERGY CALULATIONS LIST CONDITIONED
 FLOOR AREA AT 4098 SQFT AND PLANS
 INDICATE 3481 SQFT UNDER AIR. PLEASE
 CLARIFY.
  
 8)PROVIDE MANUAL "J" CALCS FOR ALL 3
 UNITS.
  
 9)PROVIDE POSITIVE AND NEGATIVE WIND
 LOADS FOR OVERHEAD GARAGE DOORS, 3FT
 GARAGE DOOR, FRONT DOOR AND WINDOWS
 ABOVE FRONT DOOR.
  
 10)PROVIDE LITERATURE ON STEEL FLOOR AND
 ROOF SYSTEMS TO BE PUT WITH PLANS FOR
 INSPECTION PURPOSES. INCLUDE SPECIFICAT-
 IONS, FASTENER DETAILS, HEADER CONSTRUCT
 -ION.
  
 11)PLEASE CLARIFY THE ATTACHMENT OF
 STEEL FLOOR JOISTS TO CONCRETE TIE BEAM
 AND STEEL ROOF RAFTERS TO WOOD WALLS.
  
 12)PLEASE CLARIFY METHOD OF ATTACHMENT
 USED TO SECURE DRYWALL TO STEEL ON
 CEILINGS.
  
 13)DETAIL ON SHEET 7 IS NOT CLEAR ON
 ATTACHMENT OF WOOD TRUSSES TO STEEL
 RAFTERS. PLEASE CLARIFY.
  
 14)PLEASE PROVIDE 2COPIES OF DESIGN
 CERTIFICATION COMPLIANCE FORMS. WET
 SIGNATURE, IMPRESSION SEAL AND DATE BY
 DESIGNER OF RECORD IS REQUIRED. SEE
 ATTACHED FORMS.
  
 15)PROVIDE PRODUCT APPROVALS FOR FRONT
 DOOR, 3FT GARAGE DOOR, FIXED GLASS
 WINDOWS AND ARCHED ARCHED WINDOWS.
  
 16)PROVIDE KEY PLAN AND INSTALLATION
 SCHEDULE FOR STORM PANELS. INDICATE THE
 SPECIFIC TYPES OF FASTENERS THAT WILL BE
 USED.
  
 IF YOU HAVE ANY QUESTIONS CALL ROBERT
 MCDOUGAL AT (561)659-8096 EXT.8202

Review Stop Z ZONING
Rev No 1 Status P Date 2000-10-18 Cont ID  
Sent By gjoyce Date 2000-10-18 Time 11:33 Rev Time 0.15
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***