Plan Review Details - Permit 00100127
Plan Review Stops For Permit 00100127
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2000-10-31 Cont ID  
Sent By drunnels Date 2000-10-31 Time 09:39 Rev Time 1.00
Received By drunnels Date 2000-10-31 Time 09:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-10-31 Cont ID  
Sent By jleahy Date 2000-10-31 Time 10:36 Rev Time 1.00
Received By jleahy Date 2000-10-31 Time 10:35 Sent To  
Notes
2001-01-08 00:00:00AIC RATING REQUIRED PRIOR TO 1ST INSP.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2000-11-15 Cont ID  
Sent By mcarsill Date 2000-11-15 Time 09:37 Rev Time 0.00
Received By mcarsill Date 2000-11-15 Time 09:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2000-10-11 Cont ID  
Sent By mcarsill Date 2000-10-11 Time 14:31 Rev Time 0.00
Received By mcarsill Date 2000-10-11 Time 14:31 Sent To  
Notes
2001-01-08 00:00:001) WRONG LIFE SAFETY CODE REFERENCED.
 SHOULD NFPA 101, LIFE SAFETY CODE, 1985
 EDITION NOT NFPA 101, LIFE SAFETY CODE,
 1997 EDITION.
 2) NO HYDRAULIC CALCULATIONS PROVIDED
 WITH FIRE SPRINKLER DRAWING.
 3) CLEARLY IDENTIFY INTERIOR FINISH
 TYPES TO BE USED IN TENANT SPACE.
 4) EXITING PERMITTED THROUGH STOCKROOM
 IF THE FOLLOWING CONDITIONS EXIST,
 AN AISLE OF AT LEAST 44" WIDE IS
 PROVIDED AND MAINTAINED, THE DOOR
 LEADING TO THE STOCKROOM IS NOT
 SUBJECT TO LOCKING, AND THIS EXIT ONLY
 PROVIDES NO MORE THAN 50 PERCENT OF
 EXIT ACCESS IS THROUGH THE STOCKROOM.
 5) PLEASE PROVIDE OCCUPANT LOAD DATA
 FOR TENANT SPACE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2000-12-04 Cont ID  
Sent By ndenmark Date 2000-12-04 Time 15:36 Rev Time 0.50
Received By ndenmark Date 2000-12-04 Time 15:36 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2000-10-30 Cont ID  
Sent By ndenmark Date 2000-10-30 Time 17:37 Rev Time 0.50
Received By ndenmark Date 2000-10-30 Time 17:36 Sent To  
Notes
2001-01-08 00:00:00*************DENIED*********************
 1. PROVIDE OUTSIDE AIR CALCULATIONS PER
 ASHRAE 62-89
 2. PROVIDE AIR BALANCE SCHEDULE SHOWING
 COMPLIANCE WITH 1997 SMC 501.2

Review Stop P PLUMBING
Rev No 4 Status P Date 2001-01-26 Cont ID  
Sent By jleech Date 2001-01-26 Time 16:17 Rev Time 0.50
Received By jleech Date 2001-01-26 Time 16:17 Sent To  
Notes
2001-01-26 00:00:00REVISION; CHANGED FROM WATER HEATER TO
 INLINE HEATER UNDER LAV.

Review Stop P PLUMBING
Rev No 3 Status P Date 2000-12-04 Cont ID  
Sent By jleech Date 2000-12-04 Time 09:49 Rev Time 0.50
Received By jleech Date 2000-12-04 Time 09:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2000-11-09 Cont ID  
Sent By pschmitz Date 2000-11-09 Time 16:49 Rev Time 1.00
Received By pschmitz Date   Time   Sent To  
Notes
2001-01-08 00:00:00CALL FROM ARCH, MR. TOM KVATERNIK
 11-09-00 TAB 407 NOTE 8 COMMON FACILITIE
 IN MALL,NOTES I,2,3,4,5 DO NOT APPLY.
 H/C REST RM FOR EMPLOYEES PROVIDED.PES

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-10-16 Cont ID  
Sent By tlarge Date 2000-10-16 Time 06:42 Rev Time 0.75
Received By pschmitz Date 2000-10-16 Time 06:42 Sent To  
Notes
2001-01-08 00:00:001)SUBMIT OCCUPANT LOAD TO DETERMINE
 COMPLIANCE W/SPC TABLE 407.SEE SPC SEC.
 407.1.3.FOR ALLOWED DEDUCTIBLE AREAS.
  
 2)A DRINKING FOUNTAIN IS REQD.PER SPC
 TABLE 407.FOUNTAIN SHALL COMPLY W/FACBC
 SEC.4.1.3.(10)(A).PROVISIONS SHALL BE
 MADE FOR PEOPLE WHO HAVE TROUBLE BENDING
 OR STOOPING.
  
 3)A MIN. OF 2 TOILET ROOMS ARE REQD.PER
 SPC TABLE 407.
  
 4)WATER HEATER SHALL BE READILY ACCESS-
 IBLE PER SPC SEC.501.7.SUPPLY SHIP'S
 LADDER OR RELOCATE HEATER TO FLOOR.
  
 5)HANDICAP ACCESSIBLE TOILET ROOMS SHALL
 BE INDELIBLY POSTED FOR THE INTENDED
 USE,BE ON AN ACCESSIBLE ROUTE AND BE
 AVAILABLE TO PATRONS WITHOUT RESTRICTION
 DURING NORMAL OPERATING HOURS.THE
 ACCESSIBLE ROUTE SHALL BE CLEARLY
 DEFINED ON THE PLANS.FACBC SECS.4.1,4.2,
 4.3 AND THE STANDARD PLUMBING CODE SEC.
 407.2.2.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.