| Plan Review Stops For Permit 00100052 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2000-11-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2000-11-02 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2000-11-02 |
Time |
12:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2001-09-29 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2001-09-29 |
Time |
07:47 |
Rev Time |
0.35 |
| Received By |
pkrauss |
Date |
2001-09-29 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2001-09-29 00:00:00 | MECH REV 01090501 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2000-10-28 |
|
|
Cont ID |
|
| Sent By |
ndenmark |
Date |
2000-10-28 |
Time |
12:29 |
Rev Time |
0.33 |
| Received By |
ndenmark |
Date |
2000-10-28 |
Time |
12:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2000-10-14 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2000-10-14 |
Time |
10:55 |
Rev Time |
1.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | PLBG PLAN REVIEW PROVISO | | | (1) RPZV ON H20 SERVICE FOR SWIMMING POO | | | (2) SHT M-1 MASTER BATH, FIXTURES DOWN | | | STREEAM OF W/C TO BE VENTED SPC 94 | | | SEC.913.2 | | | (3) REVISION BEFORE FINAL. | | | END OF COMMENTS PAUL SCHMITZ | | | 5671-659-8096 X 8233 |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2001-09-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-09-07 |
Time |
17:51 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2001-09-07 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2001-09-07 00:00:00 | TRUSS DRAWINGS REVIEW. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2001-07-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-07-18 |
Time |
16:11 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2001-07-18 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2001-07-18 00:00:00 | TRUSS DRAWINGS 2ND CHECKLIST: | | | | | | 1-TRUSS LAYOUT: ENGINEER TO PROVIDE ALL | | | HIS INFORMATION AS REQUIRED BY CHAPTER | | | 471 OF FLORIDA STATUTES. | | | (NOT DONE FROM PREVIOUS CHECKLIST) | | | 2-ONLY THE TRUSS LAYOUT , TRUSS INDEX& | | | GENERAL TRUSS DETAILS WERE SUBMITTED | | | WITH THIS PACKAGE. | | | -MISSING THE ENGINEERED TRUSS DRAWINGS. | | | -REMEMBER THAT ENGINEERED TRUSSES MUST | | | HAVE ORIGINAL SIGNATURE, DATE AND | | | EMBOSSED SEAL. CHAPTER 471 FL. STATUTE | | | AS REQUESTED ON PREVIOUS CHECKLIST. | | | 3-ENGINEER SIGNED THE GENERAL TRUSS | | | DETAILS, BUT HE DIDN'T SEALED THEM. | | | CHAPTER 471 FLORIDA STATUTES. | | | 4-PROFESSIONAL ENGINEER OF RECORD NEEDS | | | TO REVIEW ALL TRUSS DRAWINGS PRIOR TO | | | SUBMITTAL TO THIS OFFICE. (NOT DONE | | | FROM PREVIOUS CHECKLIST). | | | | | | | | | NOTE: ADDITIONAL FEES WILL BE CHARGED AT | | | TIME OF RE-SUBMITTAL. SEE ATTACHED | | | COPY OF POLICY. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2001-05-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2001-05-31 |
Time |
15:31 |
Rev Time |
1.00 |
| Received By |
jgomez |
Date |
2001-05-31 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2001-05-31 00:00:00 | TRUSS DRAWINGS CHECKLIST: | | | 1-TRUSS LAYOUT: ENGINEER TO PROVIDE ALL | | | HIS INFORMATION AS REQUIRED BY CHAPTER | | | 61G15 OF FLORIDA BOARD OF PROFESSIONAL | | | ENGINEERS. | | | 2-TRUSS ENGINEER TO PROVIDE ORIGINAL | | | SIGNATURE ON ALL DRAWINGS AND | | | DOCUMENTS SUBMITTED FOR PUBLIC RECORDS | | | AS REQUIRED BY CHAPTER 61G15. | | | 3-TRUSS ENGINEER TO UPDATE ALL GENERAL | | | TRUSS DETAILS. SEE COMMENTS ON DWGS. | | | 4-CLARIFY WHY SIGNATURE ON TRUSS LAYOUT | | | IS DIFFERENT FROM SIGNATURE ON THE | | | ENGINEERED TRUSSES IF BOTH DOCUMENTS | | | ARE SIGNED BY THE SAME ENGINEER. | | | 5-PROFESSIONAL ENGINEER OF RECORD FOR | | | THE STRUCTURE TO REVIEW ALL TRUSS | | | DRAWINGS AFTER THEY ARE CORRECTED BY | | | THE TRUSS ENGINEER. CHAPTER 61G15. | | | | | | -IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ AT 659-8096 EXT. 8232. | | | | | | | | | NOTE: | | | TRUSS ENGINEERED PACKAGE IS GOING TO BE | | | RETAINED IN THIS OFFICE TO BE SEND TO | | | THE FLORIDA BOARD OF PROFESSIONAL | | | ENGINEERS. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2000-11-16 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-11-16 |
Time |
11:48 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-11-16 |
Time |
11:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2000-11-03 |
|
|
Cont ID |
|
| Sent By |
drunnels |
Date |
2000-11-03 |
Time |
09:54 |
Rev Time |
1.00 |
| Received By |
drunnels |
Date |
2000-11-03 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2001-01-08 00:00:00 | 1.FLORIDA ENERGY EFFICIENCY SHEETS MUST | | | BE SIGNED BY OWNER/AGENT | | | 2.SUBMIT PRODUCT APPROVAL FOR WINDOWS, | | | DOORS AND ROOF COVERINGS | | | 3.SUBMIT WINDOW SPECS SHOWING COMPLIANC | | | WITH SECTION 1005.4 / 1997 EDITION SBC | | | 4. NOTICE OF COMMENCEMENT MUST BE | | | SUBMITTED PRIOR TO PERMIT BEING ISSUED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2000-10-11 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2000-10-11 |
Time |
11:48 |
Rev Time |
0.15 |
| Received By |
gjoyce |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|