Plan Review Details - Permit 00091519
Plan Review Stops For Permit 00091519
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2000-10-10 Cont ID  
Sent By dpalmer Date 2000-10-10 Time 17:05 Rev Time 0.00
Received By dpalmer Date 2000-10-10 Time 17:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2000-10-10 Cont ID  
Sent By jleech Date 2000-10-10 Time 18:26 Rev Time 0.33
Received By jleech Date 2000-10-10 Time 18:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2000-11-01 Cont ID  
Sent By tlarge Date 2000-11-01 Time 17:11 Rev Time 0.25
Received By tlarge Date 2000-11-01 Time 17:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2000-10-07 Cont ID  
Sent By tlarge Date 2000-10-07 Time 05:45 Rev Time 0.50
Received By tlarge Date 2000-10-07 Time 05:45 Sent To  
Notes
2001-01-08 00:00:001)FIXTURE SETTING SHALL COMPLY W/SPC
 SEC.403.4.
  
 2)ONE MAIN VENT REQD.THRU ROOF,MIN.3"PER
 SPC SEC.904.3.1.
  
 3)WATER CLOSET AND BIDET NOT VENTED.
 COMPLY W/SPC SEC.901.2.
  
 4)TUB DOWNSTREAM OF WATER CLOSET SHALL
 BE VENTED PER SPC SEC.913.2.
  
 5)SANITARY RISER SHALL CORRELATE W/THE
 FLOOR PLAN.COUNTYWIDE AMENDMENTS TO SPC
 SEC.104.2.1.
  
 CALL 561-659-8096,EXT.8377 IF YOU HAVE
 QUESTIONS.
 TIMOTHY LARGE
 PLUMBING PLANS EXAMINER.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2000-11-03 Cont ID  
Sent By fknapp Date 2000-11-03 Time 12:25 Rev Time 1.00
Received By fknapp Date 2000-11-03 Time 12:25 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2000-10-26 Cont ID  
Sent By fknapp Date 2000-10-26 Time 13:40 Rev Time 4.00
Received By fknapp Date 2000-10-26 Time 13:39 Sent To  
Notes
2001-01-08 00:00:00 
  
 ************BUILDING UNSAT**************
  
 SBC 104.2.2
  
 1)PROVIDE 2 CURRENT COMPLETE COPIES OF
 SBCCI OR METRO DADE PRODUCT APPROVALS
 FOR DOUBLE AND SINGLE FRENCH DOORS BEING
 USED.
  
 2)PROVIDE INSTALLATION SCHEDULE AND KEY
 PLAN FOR STORM PANELS WITH SPECIFIC
 ANCHORS AND MOUNTING TO BE USED.
  
 3)PROVIDE DESIGN CERTIFICATION FORM FOR
 BUILDING CODE COMPLIANCE.
  
 4)BEFORE A PERMIT TO CONSTRUCT CAN BE
 ISSUED,IMPACT FEES MUST BE PAID TO PALM
 BEACH CO.,THE PERMIT PLANS STAMPED BY
 THEM AND THE RECEIPT ATTACHED TO THE
 PERMIT APPLICATION.

Review Stop Z ZONING
Rev No 1 Status P Date 2000-10-05 Cont ID  
Sent By gjoyce Date 2000-10-05 Time 10:07 Rev Time 0.15
Received By gjoyce Date   Time   Sent To  
Notes
***NONE***